3
DUOX PLUS AUDIO CITYLINE-MARINE KIT 1 WAY ILOFT
2.
Press the F1 and the
button simultaneously for 5 seconds until you hear a confirmation tone
(BEEP). Release.
3.
Press the residential call button from the panel. A confirmation tone will sound on the telephone.
The phone is programmed, (red fixed led).
1.
With the telephone
connected and in
standby, press the
button for 5” until you
hear a beep, release
and listen to the current
panel´s ringtone. In this
status:
*
Note:The time from which you hear a confirmation beep upon entering the telephone´s programming to when
the call is made from the panel to program the telephone´s address must be less than 2 and a half minutes.
PROGRAMMATION
SETTINGS
1. PANEL SETTINGS
1
'Door open' warning
language selection
Spanish
English
French
German
Catalonian Valencian
Balearic
Portuguese Basque
Galician
Dutch/
Flemish
Greek
Finnish
Swedish
Turkish
Polish
Czech
Slovak
Chinese
Persian/
Farsi
Arabic
Norwegian
Danish
Icelandic
Russian
Hindi
Hungarian
Italian
Hebrew
Croatian
31...62
Bell
DEACTIVATED
bell
French
(LONG)
campana
2. HOW TO CONFIGURE THE MASTER PANEL
Press the SW1 button rapidly 3 times in a row. After 2 seconds, you will hear a confirmation tone,
and the master panel will be activated. This is necessary if you need to programme the home
terminal (monitor). Deactivate the MASTER panel by pressing the SW1 button 3 times in a row.
Panel Connectors:
B,B: DUOX PLUS Bus:
power, data and audio.
C, NO, NC:
Relay contacts 2A@30Vdc (lock-release
connection).
+12:
12 Vdc-250mA output (maximum 500mA for 100 seconds).
BS, -:
entrance hall button.
S, -:
door sensor input.
JP1:
Line adaptor switch.
P1, P2:
Button Connection
Selecting the language
1
of the “door open” message
Audio Settings
of the Telephone, panel and open door.
Microphone Connection
Amplifier Version
SW1 Button
1
2
3
< 2,5 min