Pag 13
VDS-BUS2 Programming
VDS-BUS2 Programming
MIC
NC NO C
-
BS
BUS-2
EXIT
EXIT
B B
+12
S
JP3
JP2
PACK EXTENSION
CN1
CN2
LEDS ON
SLAVE
MASTER
LEDS OFF
TARJETERO
CARD HOLDER
CN4
CN3
AUDIO
BUS-2 VERSTÄRKER
AMPLIFICATEUR BUS-2
BUS-2 AMPLIFIER
AMPLIFICADOR BUS-2
PROG
TEST
STATUS LEDS
LEDS ESTADO
LANGUAGE
IDIOMA
10
PAN & TILT
D
C
B
A
JP3
JP2
CN4
CN3
SW1
CN1
CN2
MIC
SW1
Amplifi er
To
reset mapping:
-
disconnect power supply.
-
connect the power supply to the
amplifi er by pressing the programming
button and holding it until you hear the
confi rmation beep.
ADVANCED PROGRAMMING: Lock-Release Timing
Carry out the following steps:
1.- With the power supply disconnected, short circuit the ”
Bs
” and “
-
” (negative)
amplifi er terminals (or press the exit button where one exists).
2.- Maintaining the short-circuit induced above connect the system’s power
supply (at this point it will no longer be necessary to maintain the short circuit or
hold down the exit button).
A confi rmation tone will sound once you enter programming mode.
3.- Following the confi rmation tone, the lock-release
time as currently pro-
grammed from the residence
will be indicated by way of a number of beeps
at 0.5 second intervals.
4.- Once these indicator tones have concluded, or before they conclude, press
any button on the panel, with one press for each second to be programmed
(from 1 to 99 seconds).from the residence or following the indicator tones), wait
5 seconds before taking any other action.
BUTTON Panel Programming
There are two programmable lock-release activation times:
- Lock-release time set from the residence.
- Lock-release time set from the exit button (connected to the ”BS” and “-” ter-
minals).