background image

 

FERMAX ELECTRÓNICA S. A. E. 

CITYCOM III Guard Unit Central  

 

9    

Code 94487  V-02/04 

 

DISTRIBUIDOR TENSION

VOLTAGE DISTRIBUTOR

LL-4
LL-1
LL-2

LL-3

LL-5
LL-6

6

4

2

1

3

5

LL-8

LL-1...LL-8 - LLAMADAS / CALLS

REF.84607

OUTDOOR PANEL

6

7

8

2

1

LL-7
LL-8

8

7

5

3

1

2

4

6

LL-2

LL-1

LL-4

LL-3

LL-6

LL-5

LL-8

LL-7

PLACA EXTERIOR

LLAMADAS
CALLS

Central CITYCOM III en MODO DIA/NOCHE, con Teléfonos CITYMAX de llamada por ZUMBADOR

1 2 3

CN5

CN6

CN7

CN8

LL-7

LL-1

LL-2

BUZZER CITYCOM III GUARD

UNIT

MODULO PULSADORES

BASICOS

CITYCOM III Central Unit in DAY/NIGHT MODE. CITYMAX BUZZER call telephones

CENTRAL DE CONSERJERIA

CITYCOM III  DE ZUMBADOR

BASIC PUSHBUTTON

MODULE

ABREPUERTAS

ELECTRIC LOCK

REF.2911

-

-

+ -

+ -

-

-

ALIMENTADOR

POWER SUPPLY

REF.88231

V 07/99

E 1793 01 1

T7

TELEFONO CITYMAX ZUMBADOR

BUZZER CITYMAX TELEPHONE

REF.8046

T8

T1

T2

TELEFONO CITYMAX ZUMBADOR

REF.8046

BUZZER CITYMAX TELEPHONE

MODO DIA/NOCHE

LLAMADA ZUMBADOR

DAY/NIGHT MODE

BUZZER CALL

3

2

1

5

4 6

1 2 3 4 5 6

6

3

1 2 4 5

2

1 3 5

4 6

Ab

U

F

1 2

CN1

321

3 6

Cp2

Tc

Ab

Cp1

Cp

-

+

1 2 3 6 CpCp

4C

1 2 3 6

NR-1920

220 V

3

PRIM

 

Summary of Contents for CITYCOM III CENTRAL GUARD UNIT

Page 1: ...ontrol Seg n el bot n pulsado la Central estar en uno de los tres estados posibles 1 CONSERJE VIVIENDA y VIVIENDA VIVIENDA bot n verde 2 VIVIENDA PLACA bot n amarillo 3 CONSERJE PLACA bot n rojo Exist...

Page 2: ...miten llamar desde la Central a la vivienda seleccionada Cuando se llama desde la vivienda al conserje se genera un tono de llamada en la central de conserjer a a la vez que se enciende el led del pul...

Page 3: ...lo hace volver al estado de CONSERJE VIVIENDA Para pasar a este estado desde la Central hay que pulsar el bot n amarillo En el modo AUTOMATICO la Central pasa al modo VIVIENDA PLACA autom ticamente c...

Page 4: ...gramaci n de la Central de Conserjer a Puentes CN5 CN6 y CN7 cortocircuitar 2 y 3 Puente CN8 cortocircuitar 2 y 3 Caracter sticas de la instalaci n Utilizar la Central de conserjer a CITYCOM versi n L...

Page 5: ...los cuatro tipos de comunicaci n La vivienda conecta el audio cuando es llamada desde la Central de conserjer a Posibilidad de incluir pulsador de conserjer a en la placa de calle La llamada desde est...

Page 6: ...FERMAX ELECTR NICA S A E Central de Conserjer a CITYCOM III 6 C digo 94487 V 02 04...

Page 7: ...FERMAX ELECTR NICA S A E Central de Conserjer a CITYCOM III 7 C digo 94487 V 02 04 ESQUEMAS DE INSTALACI N...

Page 8: ...cortocircuitar 1 y 2 Puente CN8 cortocircuitar 2 y 3 Caracter sticas de la instalaci n Utilizar la Central de conserjer a CITYCOM versi n Llamada por zumbador Para llamar al conserje desde una vivien...

Page 9: ...8 LL 7 LL 1 LL 2 BUZZER CITYCOM III GUARD UNIT MODULO PULSADORES BASICOS CITYCOM III Central Unit in DAY NIGHT MODE CITYMAX BUZZER call telephones CENTRAL DE CONSERJERIA CITYCOM III DE ZUMBADOR BASIC...

Page 10: ...talaci n Utilizar la Central de conserjer a CITYCOM versi n Llamada electr nica Para llamar al conserje desde una vivienda pulsar el bot n de abrepuertas NO permiten se alizaci n ni retenci n de llama...

Page 11: ...PLACA EXTERIOR LLAMADAS CALLS PORTERO Central CITYCOM III en MODO DIA NOCHE con Tel fonos CITYMAX de llamada ELECTRONICA 1 2 3 CN5 CN6 CN7 CN8 LL 7 LL 1 LL 2 CITYCOM III Central Unit in DAY NIGHT MODE...

Page 12: ...la borna Cp con la borna Cp Utilizar la Central de conserjer a CITYCOM versi n Llamada electr nica Para llamar al conserje desde una vivienda pulsar el bot n de abrepuertas NO permiten se alizaci n n...

Page 13: ...LL 1 LL 4 LL 3 LL 6 LL 5 LL 8 LL 7 PLACA EXTERIOR LLAMADAS CALLS PORTERO Central CITYCOM III en MODO AUTOMATICO con Tel fonos CITYMAX de llamada ELECTRONICA 1 2 3 CN5 CN6 CN7 CN8 LL 7 LL 1 LL 2 CITYCO...

Page 14: ...a Para llamar al conserje desde una vivienda pulsar el bot n de conserje La placa de pulsadores de la Central de conserjer a debe incorporar m dulos de retenci n de la se alizaci n Cada m dulo tiene c...

Page 15: ...L 8 8 7 5 3 1 2 4 6 LL 3 LL 4 LL 1 LL 2 E 4 E 3 E 2 E 1 E 1 E n LLAMADAS A CONSERJE CALLS TO GUARD UNIT LL 7 E7 OUTDOOR PANNEL LLAMADAS CALLS PORTERO 2 CN6 CN7 CN8 CN5 1 3 Central CITYCOM III en MODO...

Page 16: ...ctr nica Para llamar al conserje desde una vivienda pulsar el bot n de conserje La placa de pulsadores de la Central de conserjer a debe incorporar m dulos de retenci n de la se alizaci n Cada m dulo...

Page 17: ...S E8 LL 8 E1 LL 1 LL 2 E2 CITYCOM III Central Unit in AUTOMATIC MODE CITYMAX PRIVACY telephones CITYCOM III GUARD UNIT REF 84601 MODULO PULSADORES CON RETENCION CENTRAL DE CONSERJERIA CITYCOM III LATC...

Page 18: ...FERMAX ELECTR NICA S A E Central de Conserjer a CITYCOM III 18 C digo 94487 V 02 04 NOTAS OBSERVACIONES...

Page 19: ...button 2 HOUSE PANEL yellow button 3 GUARD UNIT PANEL red button There are two different call tones Continuous 570 Hz tone Call is made from house to guard unit or vice versa Tremolo sound of two alt...

Page 20: ...GUARD UNIT HOUSE The GUARD UNIT HOUSE status green LED lit is the state in which the Central will initialise every time the key is used to connect In addition the Central returns to this state automa...

Page 21: ...y when a call is made to a house from the outdoor panel GUARD UNIT PANEL In this state the Central enables communication between the outdoor panel and the guard unit To go into this state the concierg...

Page 22: ...S Guard Unit Central Programming Jumpers CN5 CN6 and CN7 short circuit 2 and 3 Jumper CN8 short circuit 2 and 3 Installation Features Use the CITYCOM Guard Unit Central Electronic Call version Press d...

Page 23: ...ral must incorporate signalling retention modules Each module has 24 line capacity Total secrecy in the 4 types of communication House connects audio when called from Guard Unit Central Possibility of...

Page 24: ...Guard Unit Central 6 Code 94487 V 02 04 Possibility of including guard unit pushbutton in the outdoor panel The call from this button is heard in the Guard Unit Central even when disconnected Pushbutt...

Page 25: ...FERMAX ELECTR NICA S A E CITYCOM III Guard Unit Central 7 Code 94487 V 02 04 INSTALLATION DIAGRAMS...

Page 26: ...rogramming Jumpers CN5 CN6 and CN7 short circuit 1 and 2 Jumper CN8 short circuit 2 and 3 Installation Features Use the CITYCOM Guard Unit Central Buzzer Call version Press door release button to call...

Page 27: ...L 7 LL 1 LL 2 BUZZER CITYCOM III GUARD UNIT MODULO PULSADORES BASICOS CITYCOM III Central Unit in DAY NIGHT MODE CITYMAX BUZZER call telephones CENTRAL DE CONSERJERIA CITYCOM III DE ZUMBADOR BASIC PUS...

Page 28: ...rcuit 2 and 3 Installation Features Use the CITYCOM Guard Unit Central Electronic Call version Press door release button to call guard unit from house NO call signalling or retention in Guard Unit Cen...

Page 29: ...CA EXTERIOR LLAMADAS CALLS PORTERO Central CITYCOM III en MODO DIA NOCHE con Tel fonos CITYMAX de llamada ELECTRONICA 1 2 3 CN5 CN6 CN7 CN8 LL 7 LL 1 LL 2 CITYCOM III Central Unit in DAY NIGHT MODE CI...

Page 30: ...Installation Features Join terminal Cp with terminal Cp Use the CITYCOM Guard Unit Central Electronic Call version Press door release button to call guard unit from house NO call signalling or retenti...

Page 31: ...1 LL 4 LL 3 LL 6 LL 5 LL 8 LL 7 PLACA EXTERIOR LLAMADAS CALLS PORTERO Central CITYCOM III en MODO AUTOMATICO con Tel fonos CITYMAX de llamada ELECTRONICA 1 2 3 CN5 CN6 CN7 CN8 LL 7 LL 1 LL 2 CITYCOM I...

Page 32: ...entral Electronic Call version Press guard unit button to call guard unit from house Pushbutton panel of the Guard Unit Central must incorporate signalling retention modules Each module has 24 line ca...

Page 33: ...8 7 5 3 1 2 4 6 LL 3 LL 4 LL 1 LL 2 E 4 E 3 E 2 E 1 E 1 E n LLAMADAS A CONSERJE CALLS TO GUARD UNIT LL 7 E7 OUTDOOR PANNEL LLAMADAS CALLS PORTERO 2 CN6 CN7 CN8 CN5 1 3 Central CITYCOM III en MODO DIA...

Page 34: ...CITYCOM Guard Unit Central Electronic Call version Press guard unit button to call guard unit from house Pushbutton panel of the Guard Unit Central must incorporate signalling retention modules Each m...

Page 35: ...8 LL 8 E1 LL 1 LL 2 E2 CITYCOM III Central Unit in AUTOMATIC MODE CITYMAX PRIVACY telephones CITYCOM III GUARD UNIT REF 84601 MODULO PULSADORES CON RETENCION CENTRAL DE CONSERJERIA CITYCOM III LATCHIN...

Page 36: ...FERMAX ELECTR NICA S A E CITYCOM III Guard Unit Central 18 Code 94487 V 02 04 NOTES REMARKS...