FERMAX ELECTRÓNICA S. A. E.
CITYCOM III Guard Unit Central
4
Code 94487 V-02/04
INSTALLATION DIAGRAMS
•
E 1793 01 1
CITYCOM CENTRAL UNIT IN DAY MODE
CITYMAX BUZZER CALL TELEPHONES
Guard Unit Central Programming
Jumpers CN5 ,CN6 and CN7: short circuit 1 and 2
Jumper CN8: short circuit 2 and 3
Installation Features
-
Use the CITYCOM Guard Unit Central “Buzzer Call” version.
-
Press door release button to call the guard unit.
-
NO call signalling or retention in Guard Unit Central.
-
NO secret mode in any of the 4 types of communication.
-
NO possibility of including guard unit pushbutton in the outdoor panel.
•
E 1794 01 1
CITYCOM CENTRAL UNIT IN DAY MODE
CITYMAX ELECTRONIC CALL TELEPHONES
Guard Unit Central Programming
Jumpers CN5 ,CN6 and CN7: short circuit 2 and 3
Jumper CN8: short circuit 2 and 3
Installation Features
-
Use the CITYCOM Guard Unit Central “Electronic Call” version.
-
Press door release button to call guard unit from house.
-
NO call signalling or retention in Guard Unit Central.
-
NO secret mode in any of the 4 communication types.
- Possibility of including guard unit pushbutton in the outdoor panel. The call from this
button is heard in the Guard Unit Central even when it is disconnected. Pushbutton not
monitored in the outdoor panel.
•
E 1795 01 1
CITYCOM CENTRAL UNIT IN AUTOMATIC MODE
CITYMAX ELECTRONIC CALL TELEPHONES
Guard Unit Central Programming
Jumpers CN5 ,CN6 and CN7: short circuit 2 and 3
Jumper CN8: short circuit 1 and 2
Installation Features
- Join terminal
Cp
↓
with terminal
Cp
↑
.
- Use the CITYCOM Guard Unit Central “Electronic Call” version.