background image

Pag. 1

Technical

INDEX

General information about the Door Phone and Video Door Phone systems ......................... 2
Components of the Door Phone and Video Door Phone systems ........................................ 3
Denomination of the City Line panels ............................................................................... 8
CityMax Modular Panels .................................................................................................11
Practical advice on the installation ........................................................................................ 12
Understanding the diagrams .................................................................................................. 17
Starting up the installation ..................................................................................................... 18

AUDIO DOOR PHONE WIRING DIAGRAMS

E1.1  Basic installation ......................................................................................................... 19
E1.2  Installation with privacy telephones   5+N ..................................................................... 21
E1.3  Installation with privacy telephones  4+N ...................................................................... 23
E1.4  Building with two entrances ......................................................................................... 25
E1.5  Building with three entrances ....................................................................................... 27
E1.6  Condominium with several blocks ................................................................................ 29
E1.7  City Line Guard Unit .................................................................................................... 35
E1.8  Citycom III. Basic version ............................................................................................. 37
E1.9  Citycom III. Featuring retention light ............................................................................. 39

VIDEO DOOR PHONE WIRING DIAGRAMS

E2.1  Basic installation ......................................................................................................... 41
E2.2  Installation with privacy monitors  5+N ......................................................................... 43
E2.3  Building with two entrances ......................................................................................... 45
E2.4  Buildings with three entrances ..................................................................................... 49
E2.5  Condominium with several blocks ................................................................................ 53

COMPLEMENTARY INSTALLATIONS

Connection of a call tone extension ....................................................................................... 59
Activation of additional lights or bells ..................................................................................... 59
Enlarging the installation with additional monitors and /or telephones .................................... 60
Activating the "stair light" ...................................................................................................... 61
Seeing the monitor image and hearing the sound with a television set ................................... 62
Opening the hall door from inside .......................................................................................... 62
Opening a second door ......................................................................................................... 62
Opening a common door to two entrances ............................................................................ 63

PRACTICAL GUIDE AND GENERAL DIAGRAMS  FOR INSTALLERS OF FERMAX DOOR PHONE AND VIDEO DOOR
PHONE SYSTEMS
Third  Edition: May  2003  (Cod. 94727-ING  V 05/03).
This technical document is edited by FERMAX ELECTRONICA S.A.E. for informative purposes, and the right to modify
technical characteristics at any time and without previous warning is reserved.
These changes would be applied to later editions of the same.

Pag.1

Summary of Contents for AMPLIFIER MODULE CITYMAX

Page 1: ...n 41 E2 2 Installation with privacy monitors 5 N 43 E2 3 Building with two entrances 45 E2 4 Buildings with three entrances 49 E2 5 Condominium with several blocks 53 COMPLEMENTARY INSTALLATIONS Conne...

Page 2: ...the characteristics neccessary for correct functioning of the system They are usually installed in the hall or commun area of the building Video distributors are neccessary whenever the video signal...

Page 3: ...tain the optimum volume depending on the background noise and to avoid feed back from the other telephones It works with FERMAX telephones as well as any other brand so that you could also use them fo...

Page 4: ...ack it allows the door to be opened but using a Proximity Card that only has to be placed near the sensor physical contact is not neccessary However it is neccessary for the proximity sensor to have b...

Page 5: ...telephones feature a volume control and or an indicator light which advises that it is set at minimum level Consult our General Catalogue Depending on its technical characteristics but not on the cla...

Page 6: ...next to the receiver In other way and deppending on the electronic features monitors can be standard or privacy See previous page COMPONENTS OF THE DOOR PHONE AND VIDEO DOOR PHONE SYSTEMS The Installa...

Page 7: ...t the audio and lock opening systems work if there is a power failure 12 Vac output in normal conditions and 12 Vdc in a power failure It includes a quick recharging battery 10 elements rail DIN forma...

Page 8: ...l or combination of panels neccessary for a specific installation FERMAX has designed a code system called PICTORIAL which is comprised of A A number from one to nine that indicates the series B A com...

Page 9: ...ncludes Single Pushbuttons 06 It has 6 pushbuttons wich being singles allow six dwellings to be called Panel type 8AWP106 Panel type 6AVP205 Panel type 3AP203 This can be used for a six dwelling video...

Page 10: ...5P206 Examples of panel combinations A door phone installation for 30 dwellings with 4 on each floor and where the pushbutton configuration corresponds to the distribution of dwellings In the window...

Page 11: ...2502 R f 2503 R f 2504 R f 2505 R f 2506 R f 2507 R f 2515 CITYMAX BUS PUSHBUTTON MODULES With bus pushbutton modules there is no need to use anymore the call extension modules Every module includes t...

Page 12: ...o be bought apart 1 7m PRACTICAL ADVICE ON THE INSTALLATION Before installing the mounting box make whatever holes are neccessary to introduce the wires The mounting boxes have various holes indicated...

Page 13: ...ty buildings on the seafront etc If it is a video door phone installation then choose a place where it is not in direct sunlight so as to avoid problems of background light in the camera Before positi...

Page 14: ...hinges to wire the electrical connections more easily These hinges which remain hidden once the box is mounted allow the panel to be hinged in any direction to the left to the right upwards and even...

Page 15: ...the camera etc you can remove the protection covers with the help of a screwdriver Installing CityMax telephones The telephone base features multiple fixing points Use the four most convenient ones w...

Page 16: ...ing outdoor Volume adjustment outdoor dwelling Pan tilt adjustment FL AT MO NIT OR HIG H RE SO LU TIO N 2 1 2 1 3 Attaching the monitor The monitor can be attached at any other time following the step...

Page 17: ...e h t g n i t a v i t c A 2 s m a r g a i d l l A t e e r t s e h t o t g n i l l e w d e h t m o r f o i d u A 3 s m a r g a i d l l A e v i t a g e n n o m m o C l l a c 4 s m a r g a i d l l A g n...

Page 18: ...t light up when there is a call although the call is heard When a call is made to the monitor the LED indicator which is normally on should be off all the time that the image is on screen If the LED g...

Page 19: ...a determined button on the outdoor panel cau ses a call signal Cp1 to be generated by the amplifier and sent along the call line to the corresponding telephone which will then ring with the character...

Page 20: ...12Vac PRIM n 1 T n T 2 T 1 T 1 A 1 F 1 P n 1 n 3 1 2 6 4 3 1 2 6 4 3 1 2 6 4 3 1 2 6 4 CN1 1 2 3 U F 6 1 2 3 PT2 PT1 Ab Cp2 Ab Tc Cp1 INT EXT SECTION TABLE Distances up to 300 meters 0 5 mm 1 mm 2 2...

Page 21: ...ll tone At the same time it will enable the telephone audio circuits Therefore the telephones that have not been called will have their audio circuit disabled Upon picking up the receiver a switch con...

Page 22: ...S 5 N Vac n 1 2 1 n 4 1 2 3 6 4 1 2 3 6 2 1 4 3 6 2 1 4 3 6 PRIM F1 7 A 1 P 1 T 2 T n 1 T Tn CN1 EXT INT 3 PT1 PT2 1 2 F U 1 3 2 6 Ab Cp2 Ab Cp1 Tc SECTION TABLE Distances up to 300 meters 0 5 mm 1 mm...

Page 23: ...outdoor panel It is very important that the connection cables from this module to the amplifier are as short as possible so as to avoid problems with noise General diagram for Door Phone installation...

Page 24: ...Pag 24 Technical WIRNG DIAGRAM E 1 3 DOOR PHONE SYSTEM INSTALLATION WITH PRIVACY TELEPHONES 4 N...

Page 25: ...he at rest panel and P2 the activated panel MATERIAL NEEDED In the dwellings T1 T2 Tn CitymaxTelephones Ref 8044 In the internal common area A7 Distributor Power Supply Ref 88231 A5 Audio Switcher Ref...

Page 26: ...6 4 3 1 2 6 4 3 1 2 6 4 CN1 EXT INT 3 PT1 PT2 1 2 F U 1 3 2 6 Ab Cp2 Ab Cp1 Tc CN1 EXT INT 3 PT1 PT2 1 2 F U 1 3 2 6 Ab Cp2 Ab Cp1 Tc SECTION TABLE Distances up to 300 meters 0 5 mm 1 mm 2 2 Call Call...

Page 27: ...ng communication with the outdoor panel from which the call was made MATERIAL NEEDED In the dwellings T1 T2 Tn Citymax Telephones Ref 8044 In the communal interior area A1 1 A1 2 Audio Power Supply Re...

Page 28: ...Vac Vac 3 1 2 6 4 3 1 2 6 4 3 1 2 6 4 3 1 2 6 4 CN1 EXT INT 3 PT1 PT2 1 2 F U 1 3 2 6 Ab Cp2 Ab Cp1 Tc CN1 EXT INT 3 PT1 PT2 1 2 F U 1 3 2 6 Ab Cp2 Ab Cp1 Tc CN1 EXT INT 3 PT1 PT2 1 2 F U 1 3 2 6 Ab...

Page 29: ...automatic switcher have an activated position in which the conversation time is limited to 90 seconds or until a call is produced from another panel and another at rest in which the conversation will...

Page 30: ...Pag 30 Technical SCHEMATIC DIAGRAM E 1 6 DOOR PHONE SYSTEM CONDOMINIUM WITH SEVERAL BLOCKS B 3 B 3 B 3 B 3 PG 3 P 3 F 3...

Page 31: ...n 1 n 6 3 2 1 3 2 1 6 3 1 2 6 Vac SEC 12Vac PRIM CN1 1 2 3 U F 6 1 2 3 PT2 PT1 Ab Cp2 Ab Tc Cp1 INT EXT TO THE MIDDLE BLOCK DIAGRAM TO THE LAST BLOCK DIAGRAM TO THE FIRST BLOCK DIAGRAM Calls block 2 C...

Page 32: ...1 2 3 6 Vac PRIM 3 1 2 6 4 3 1 2 6 4 3 1 2 6 4 3 1 2 6 4 CN1 1 2 3 U F 6 1 2 3 PT2 PT1 Ab Cp2 Ab Tc Cp1 INT EXT SECTION TABLE Distances up to 300 meters 0 5 mm 1 mm 2 2 CUT Cut the common pushbutton...

Page 33: ...1 2 3 6 Vac PRIM 3 1 2 6 4 3 1 2 6 4 3 1 2 6 4 3 1 2 6 4 CN1 1 2 3 U F 6 1 2 3 PT2 PT1 Ab Cp2 Ab Tc Cp1 INT EXT SECTION TABLE Distances up to 300 meters 0 5 mm 1 mm 2 2 CUT Cut the common pushbutton...

Page 34: ...1 2 3 6 Vac PRIM 3 1 2 6 4 3 1 2 6 4 3 1 2 6 4 3 1 2 6 4 CN1 1 2 3 U F 6 1 2 3 PT2 PT1 Ab Cp2 Ab Tc Cp1 INT EXT SECTION TABLE Distances up to 300 meters 0 5 mm 1 mm 2 2 Cut the common pushbutton wire...

Page 35: ...from his panel with his phone The residents can call the concierge by picking up their phone and pressing the door release button which produces an audible signal in the guard unit The concierge can...

Page 36: ...1 1 2 n PANEL OUTDOOR TELEPHONES EXIT CP 6 3 2 1 6 3 2 1 NR 0631 n 1 1 2 n PRIM 3 1 2 6 4 3 1 2 6 4 3 1 2 6 4 3 1 2 6 4 CN1 1 2 3 U F 6 1 2 3 PT2 PT1 Ab Cp2 Ab Tc Cp1 INT EXT SECTION TABLE Distances...

Page 37: ...e resident by simply picking up his receiver When it is off night mode the calls made from the outdoor panel are sent directly to the telephone called the system working in the normal way From the gua...

Page 38: ...1 2 6 4 3 1 2 6 4 3 1 2 6 4 3 1 2 6 4 2 n 1 n 1 1 CN5 CN6 CN7 CN8 2 3 2 n 1 n 1 PRIM Cp 3 4C 1 2 Cp 6 Cp NR 1920 3 2 1 6 CN1 1 2 3 U F 6 1 2 3 PT2 PT1 Ab Cp2 Ab Tc Cp1 INT EXT Call Call To the call te...

Page 39: ...ling him and so can return the call at an time A reset button allows the concierge to put out all the lights When it is off night mode the calls from the outdoor panel are sent directly to the dwellin...

Page 40: ...E22 E23 E24 S4 S1 S16 S13 S8 S5 S12 S9 S20 S17 S24 S21 P P 1 P 2 3 4 P 6 6 4 3 2 1 6 3 2 1 4 6 4 3 2 1 NR 1936 6 4C Cp 2 1 3 Cp Cp 2 1 3 6 NR 1920 Vac PRIM CN1 1 2 3 U F 6 1 2 3 PT2 PT1 Ab Cp2 Ab Tc C...

Page 41: ...enerated in the amplifier to be sent along the call line to the corresponding monitor which pro duces the typical tremolo call tone At the same time the screen will switch itself on showing the image...

Page 42: ...18 R1 75 2 OUTPUTS VIDEO DISTRIBUTOR REF 2448 1 5 2 6 4 6 7 E S CT 1 2 3 M V V M 3 S E 7 6 4 CT 2 1 M V V M 4 6 7 E S CT 1 2 3 M V V M 4 6 7 E S CT 1 2 3 M V V M DISTRIBUIDOR VIDEO 2 SALIDAS DISTRIBUI...

Page 43: ...a switch connects the telephone to the common audio cables 2 6 thus establishing communication with the outdoor panel Pressing the door release button on the monitor unites the wires 1 3 of the instal...

Page 44: ...V V 18 R1 75 2 OUTPUTS VIDEO DISTRIBUTOR REF 2448 1 5 2 6 4 6 7 E S CT 1 2 3 M V V M 3 S E 7 6 4 CT 2 1 M V V M 4 6 7 E S CT 1 2 3 M V V M 4 6 7 E S CT 1 2 3 M V V M DISTRIBUIDOR VIDEO 2 SALIDAS DIST...

Page 45: ...et a switch connects the moni tor to the common audio wires 2 6 thus establishing communication with the outdoor panel from where the call was made Upon pressing the door release button on the monitor...

Page 46: ...A L K B C D E G SV SV E1 E2 5 M 1 2 4 3 6 O Q P R U S T V W Z Y X CN1 1 2 3 U F 6 1 2 3 PT2 PT1 Ab Cp2 Ab Tc Cp1 INT EXT CN1 1 2 3 U F 6 1 2 3 PT2 PT1 Ab Cp2 Ab Tc Cp1 INT EXT SECTION TABLE Distances...

Page 47: ...Pag 47 Technical WIRING DIAGRAM FLOORS 2 DWELLINGS PER FLOOR DISTRIBUTION E 2 3 VIDEO PHONE SYSTEM BUILDING WITH TWO ENTRANCES...

Page 48: ...Pag 48 Technical WIRING DIAGRAM FLOORS 4 DWELLINGS PER FLOOR DISTRIBUTION E 2 3 VIDEO PHONE SYSTEM BUILDING WITH TWO ENTRANCES...

Page 49: ...on is limited to 90 seconds whichever the panel originating the call After this time the call is ended This diagram shows an installation with three entrances For an installation with more entrances w...

Page 50: ...EST DE PRUEBA CONECTOR TEST DE PRUEBA CONECTOR TEST DE PRUEBA CN1 1 2 3 U F 6 1 2 3 PT2 PT1 Ab Cp2 Ab Tc Cp1 INT EXT CN1 1 2 3 U F 6 1 2 3 PT2 PT1 Ab Cp2 Ab Tc Cp1 INT EXT CN1 1 2 3 U F 6 1 2 3 PT2 PT...

Page 51: ...Pag 51 Technical WIRING DIAGRAM FLOORS DISTRIBUTION IN 2 DWELLINGS PER FLOOR E 2 4 VIDEO PHONE SYSTEM BUILDING WITH THREE ENTRANCES...

Page 52: ...Pag 52 Technical WIRING DIAGRAM FLOORS DISTRIBUTION IN 4 DWELLINGS PER FLOOR E 2 4 VIDEO PHONE SYSTEM BUILDING WITH THREE ENTRANCES...

Page 53: ...e and another at rest in which the conversation is only ended if there is a call from the other panel the cables from the main entrance are connected to the at rest terminals and those of the block to...

Page 54: ...Pag 54 Technical SCHEMATIC DIAGRAM E 2 5 VIDEO PHONE SYSTEM CONDOMINIUM WITH SEVERAL BLOCKS B 3 B 3 B 3 B 3 PG 3 P 3 F 3 C 3...

Page 55: ...c PRIM PRIM SEC 18Vdc 220V Vac F E 2 1 n 1 n 2 1 n 1 n 2 1 n 1 n CONECTOR TEST DE PRUEBA CT V M CN1 EXT INT 3 PT1 PT2 1 2 F U 1 3 2 6 Ab Cp2 Ab Cp1 Tc TO THE MIDDLE BLOCK DIAGRAM TO THE LAST BLOCK DIA...

Page 56: ...EF 2448 6 2 3 4 V M V M 3 4 V 2 M V 6 M 4 6 7 E S 2 3 CT 1 S M V V M M V V M 3 E 7 6 4 2 CT 1 4 6 7 E S CT 1 2 3 M V V M 4 6 7 E S CT 1 2 3 M V V M 2 1 n 1 n DISTRIBUIDOR VIDEO 2 SALIDAS DISTRIBUIDOR...

Page 57: ...2 3 4 V M V M 3 4 V 2 M V 6 M 4 6 7 E S 2 3 CT 1 S M V V M M V V M 3 E 7 6 4 2 CT 1 4 6 7 E S CT 1 2 3 M V V M 4 6 7 E S CT 1 2 3 M V V M 2 1 n 1 n DISTRIBUIDOR VIDEO 2 SALIDAS DISTRIBUIDOR VIDEO 2 SA...

Page 58: ...O DISTRIBUTOR 2 OUTPUTS VIDEO DISTRIBUTOR 18 1 5 V V M 75 M R1 REF 2448 V 5 V 1 M 75 M R1 REF 2448 6 2 3 4 V M V M 3 4 V 2 M V 6 M 2 1 n 1 n DISTRIBUIDOR VIDEO 2 SALIDAS DISTRIBUIDOR VIDEO 2 SALIDAS C...

Page 59: ...mption 2 A 400 watts if using the 220 supply can be connected to the outlet of this equipment CONNECTING TO A MONITOR CONECTING TO A TELEPHONE 110 240Vac 2A F1 Red 3 4 4 1 2 3 6 ACTIVADOR DE LUCES LIG...

Page 60: ...ne system with additional telephones spread out through the dwelling In video door phone installations an additional monitor can be installed without the need to add transformers See observations MATE...

Page 61: ...evision screen MATERIAL NEEDED A cable with a male Euroconnector to which a cable must be soldered as shown in the diagram below to be connected to the monitor The television must have a Euroconnector...

Page 62: ...s unblocked If this is not possible then it will be neccessary to install a different type of door release Ref 2909 which stays unblocked once activated until the door is opened Opening a second door...

Page 63: ...ONS 4 4 3 REF 2013 3 LE 3 4 Max 2A STAIRS LIGHT RELAY REF 2013 4 3 LE Max 2A STAIRS LIGHT RELAY 220 Vac 220 Vac REF 8787 POWER SUPPLY REF 8787 POWER SUPPLY SEC 12Vac PRIM 220V SEC 12Vac PRIM 220V RELE...

Page 64: ...g on the mains supply R E W O P O I D U A Y L P P U S R E W O P R O T U B I R T S I D Y L P P U S Y L P P U S R E W O P O E D I V c a V 0 1 1 5 8 7 8 1 1 2 8 8 2 0 3 8 8 c a V 5 2 1 6 8 7 8 1 2 2 8 8...