3

ECC+ 230 V Electronic Module

The unit has to be programmed using the DIP switches on the front of the unit. If any 

change is made to any of the above switch selections, the unit must be switched OFF 

and ON again to read the new programming. 
The switches functions are:

Working.
ON:

 Encoder.

The door movement control will be done using the motor encoder or the motor encoder 

and a close limit switch.

OFF: 

Limit switch.

The door movement control will be done using an open limit switch and a close limit 

switch.

Motor (This option is only used with the motor ELVI 104661 FCE).
ON: 

Special Motor.

Different control is applied to perform the door movement with a special motor.

OFF: 

Standard Motor.

Standard control is applied to perform the door movement.

Door model (This option is only used with the motor ELVI 104661 FCE).
ON: 

Heavy door.

The motor supplies a 30% extra torque to be able to move heavy doors.

OFF: 

Standard door.

Standard control is applied to perform the door movement.

Floor level.

Inputs

12 V battery

ON

2 Inputs

1 Input

OFF

 

Note:

 With DIP-switch No. 4 OFF is necessary to install a floor level contact in each floor.

J209 

1 and 2 INPUTS.

 

1 Input (1-IN 

).

The door control unit will be controlled by a single input. Any voltage between 24 V DC 

to 60 V DC or 100 V AC to 230 V AC applied between terminals 10 and 12 will close the 

doors. Without input active the door remains opened. Open input is not used.

2 Inputs (2-IN 

).

The door control unit will be controlled by two independent inputs. Any voltage between 

24 V DC to 60 V DC or 100 V AC to 230 V AC applied between terminals 10 and 12 will 

cause the doors to close. And between terminals 8 and 10 will cause the doors to open. 

In the absence of a signal, the doors will remain static. If both inputs are applied then the 

open signal has priority.

1

O

N

2 3 4

O

F

F

PROGRAMMING

Summary of Contents for ECC+ 230 V

Page 1: ...MAN MUED00000ENGTC 12 2017 ENG User manual Automatic horizontal sliding car door Component ECC 230 V Electronic Module...

Page 2: ...WITCH CONTACTO SEGURIDAD SAFETY SWITCH REABRIR 2 REOPEN 2 REABRIR 1 REOPEN 1 SE AL DE PISO FLOOR LEVEL F C CERRAR CLOSE L S CON ENCODER WITH ENCODER ABIERTA CERRADA OPEN CLOSED OK STATUS SPECIAL ESPEC...

Page 3: ...FCE ON Heavy door The motor supplies a 30 extra torque to be able to move heavy doors OFF Standard door Standard control is applied to perform the door movement 4 Floor level Inputs 12 V battery ON 2...

Page 4: ...This supply must only be used for this purpose b This contact must be isolated from any other power supply 12 Close signal This signal is used for ordering to close the door 13 14 Floor level This inp...

Page 5: ...D lit constantly on LED blinking iso phase on and off with a frequency of approximately 5 Hz on for approximately 100 ms followed by off for approximately 100 ms LED single flash one short flash appro...

Page 6: ...a power stage with a current limiting protection The 24 V DC motor incorporates a thermal protection in order to inform the lift controller in case of motor overheating Once the thermal protection is...

Page 7: ...signal is necessary to check that the car door s is are in the closed position To comply with this point an additional door contact is added and the signal has to be connected to the lift controller T...

Page 8: ...sultant damage produced in the equipment described in this manual and associated installation if the instructions given have not been followed TECNOLAMA reserves the right to modify the product or spe...

Reviews: