AUTOMATIC DOORS FOR LIFTS

6

ECC 230 V

31 / 32 

Limit switch with encoder.

 

   

Limit switch connection if used with encoder. With DIP-switch No. 1 ON is necessary to 

install a close limit switch.

    

33 / 34 / 35 / 36  Limit switch without encoder.

 

   

Limit switch connection if used without encoder. With DIP-switch No. 1 OFF is necessary 
to install an open and close limit switch.

37   

Motor and encoder.

 

   

Output to the 24 DC motor to control speed and torque. The ECC - 230 V motor controller is 

formed by a power stage with a feedback speed control circuit with voltage compensation 

and current limiting protections (Imax).

38   

Test pushbutton.

 

   

Operation of the Test pushbutton will cause a door open or close cycle.

39   

Safety.

 

   

La velocità di apertura della porta può essere regolata da 100 mm/s fino a 300 mm/s.

40   

Close speed.

 

   

The door closing speed can be independently adjusted from 100 mm/s up to 300 mm/s.

41   

Open speed.

 

   

The door opening speed can be independently adjusted from 100 mm/s up to 300 mm/s.

42   

On / Off switch.

 

   

Disconnects the unit from the 230 V AC mains supply.

 

POWER SUPPLY

•  DC voltage range  

 

 

 

230 V +10%, -15%. AC/DC.

•  Minimum power  

 

 

 

83 mA   

2,8 W.

•  Average power (240 cycles/hour)    

 

0,17 A    

14,7 W.

•  Maximum power  

 

 

 

0,27 A    

33,7 W.

 

PWM REGULATION 

• 

PWM 

frequency    15KHz.

•  Voltage range   

 

 

 

0...24 V DC III. 

•  Maximum output current   

 

 

2 A. 

•  Positional control:  

 

 

 

Quadrature encoder.

 

MOTOR 

•  Brushed DC motor
• 

Voltage 

supply 

    24 

V. 

• 

Power 

 

    7 

W. 

• 

Enclosure 

class 

    IP 

20. 

• 

Nominal 

speed 

    17 

rpm.

REFERENCE DATA

INPUTS

Summary of Contents for ECC 230 V

Page 1: ...MAN MUEC00000ENGTC 05 2016 ENG Assembly manual Automatic horizontal sliding car door Component ECC 230 V Electronic Module AUTOMATIC DOORS FOR LIFTS...

Page 2: ...PEN THE COVER FUERZA SAFETY OPEN SPEED VELOCIDAD ABRIR VELOCIDAD CERRAR CLOSE SPEED PULSAR PARA VERIFICAR PUSH TO CHECK THE DOOR SPECIAL ESPECIAL STANDARD EST NDAR MOTOR ENCODER FINAL CARRERA LIMIT SW...

Page 3: ...ra torque to be able to move heavy doors OFF Standard door Standard control is applied to perform the door movement 4 Floor level Inputs 12 V battery ON 2 Inputs 1 Input OFF Note With DIP switch No 4...

Page 4: ...ed 12 V output available to control the door via a voltage free contact Features are a This supply must only be used for this purpose b This contact must be isolated from any other power supply 12 Clo...

Page 5: ...approximately 5 Hz on for approximately 100 ms followed by off for approximately 100 ms LED single flash one short flash approximately 100 ms followed by a long off phase approximately 2 250 ms 21 22...

Page 6: ...tion of the Test pushbutton will cause a door open or close cycle 39 Safety La velocit di apertura della porta pu essere regolata da 100 mm s fino a 300 mm s 40 Close speed The door closing speed can...

Page 7: ...ximum 5 A Voltage 240 V PERFORMANCE Open Speed 100 300 mm s Close speed 100 300 mm s Safety force 40 150 N adjustable REFERENCE DATA DECLARATION OF CONFORMITY Herewith declares that the products menti...

Page 8: ...manual before testing it should be notified to our Technical Department TECNOLAMA accepts no responsability in the event of any damage produced in the equipment described in this manual and associate...

Reviews: