AUTOMATIC DOORS FOR LIFTS
6
ECC 230 V
31 / 32
Limit switch with encoder.
Limit switch connection if used with encoder. With DIP-switch No. 1 ON is necessary to
install a close limit switch.
33 / 34 / 35 / 36 Limit switch without encoder.
Limit switch connection if used without encoder. With DIP-switch No. 1 OFF is necessary
to install an open and close limit switch.
37
Motor and encoder.
Output to the 24 DC motor to control speed and torque. The ECC - 230 V motor controller is
formed by a power stage with a feedback speed control circuit with voltage compensation
and current limiting protections (Imax).
38
Test pushbutton.
Operation of the Test pushbutton will cause a door open or close cycle.
39
Safety.
La velocità di apertura della porta può essere regolata da 100 mm/s fino a 300 mm/s.
40
Close speed.
The door closing speed can be independently adjusted from 100 mm/s up to 300 mm/s.
41
Open speed.
The door opening speed can be independently adjusted from 100 mm/s up to 300 mm/s.
42
On / Off switch.
Disconnects the unit from the 230 V AC mains supply.
POWER SUPPLY
• DC voltage range
230 V +10%, -15%. AC/DC.
• Minimum power
83 mA
2,8 W.
• Average power (240 cycles/hour)
0,17 A
14,7 W.
• Maximum power
0,27 A
33,7 W.
PWM REGULATION
•
PWM
frequency 15KHz.
• Voltage range
0...24 V DC III.
• Maximum output current
2 A.
• Positional control:
Quadrature encoder.
MOTOR
• Brushed DC motor
•
Voltage
supply
24
V.
•
Power
7
W.
•
Enclosure
class
IP
20.
•
Nominal
speed
17
rpm.
REFERENCE DATA
INPUTS