![Fermator ECC 230 V Assembly Manual Download Page 5](http://html1.mh-extra.com/html/fermator/ecc-230-v/ecc-230-v_assembly-manual_553900005.webp)
AUTOMATIC DOORS FOR LIFTS
5
ECC 230 V
INPUTS
15 / 16 / 17
Battery.
This input is for connecting a 12 V battery 2,2 Ah to act as external emergency power
supply and allows the opening movement of the door in case of power failure.
Output relay
Output relay have been provided to give continuous information to the main lift controller
concerning the status of the doors.
18 / 19 / 20
Open.
Relay activated when the doors are fully open.
LED INDICATORS:
Ok status.
Red LED indicates proper working conditions.
Depending on how the ECC - 230 V is powered, red LED lights up in different ways:
12 V battery
230 V power supply
Red LED
Lighting
Blinking
Single flash
– LED lighting: constantly on.
– LED blinking: iso-phase on and off with a frequency of approximately 5 Hz: on for
approximately 100 ms followed by off for approximately 100 ms.
– LED single flash: one short flash (approximately 100 ms) followed by a long off phase
(approximately 2.250 ms).
21 / 22 / 23
Serial switch.
Connection serial exit-entrance. It must be connected in series with the external lock series.
24 / 25 / 26
Safety switch.
Direct connection between the entrance and the exit without any influence in the electrical
circuit function.
27 / 28 / 29 / 30 Reopen.
This connections are in serial and when it’s activated the door reopens. It is very useful for
the photocell, the cabin push-button or any other device that initiates the reopening process
when the door starts to close. It does not activate when the door is closed. As it is a serial
connection it is necessary to over-bridge the free one.
20
18
19
OPEN
Indicator states and flash rates
Blinking
Lighting
Single
flash
100
100
2250
ms
ms
ms
ms
100
on
on
on
off
off
off