6.   Wipe all surfaces of the unit with a damp clean 

cloth.

7.   Engage the gun safety lock.

CAUTION: ALWAYS turn off the unit’s motor 

BEFORE turning off the unit’s water supply.
Serious damage could occur to the motor if the 
unit is run without water. 

CAUTION: NEVER disconnect the high-pressure 

discharge hose from the machine while the 
system is still pressurized. To depressurize the 
unit, turn off the motor, turn off the water supply 
and squeeze the trigger 2-3 times

Water supply

•   Ensure that you have a suitable water supply 

to feed the pressure washer. Check that all 
connections are tight and there are no leaks in 
the hose. 

•   The supply tap should be fully open (do not 

turn on the pressure washer yet).

•   Now depress the trigger (unlock trigger lock 

first) to let water pass through the unit and 
expel any air.

Warning! This unit is to be used with a 
cold-water source only! 

•   Turn on the pressure washer, once all the air 

has been expelled and water has reached the 
end of the lance.

Electrical Cables

•   Ensure that all cables are damage free before 

connecting to the power supply. 

   Plug in the pressure washer and turn the unit 

on with the main switch (2).

4. USE

 CAUTION! The cleaner must only be 
used with clean water; use of unfiltered 
water or corrosive chemicals will damage 
the cleaner.

•  Turn the motor switch to the “0” position.
•   Check that the electrical supply voltage and 

frequency (Volts/Hz) correspond to those 
specified on the cleaner data plate.

•   If the power supply is correct, you may now 

plug in the cleaner.

•   The electric supply connection shall be made 

by a qualified electrician. It is recommended 
that the electric supply to this appliance 
should include either a residual current device 
that will interrupt the supply if the leakage 
current to earth exceeds 30 mA for 30 ms or a 
device which will prove the earth circuit.

CAUTION! The machine may cause 
electrical disturbances when starting.

•   If the motor stops and fails to restart, wait 2-3 

minutes before restarting. THERMAL CUTOUT 
TRIPPED

Adjusting the nozzle

Fig. 2

•   Water may be sprayed out of the nozzle either 

linearly or in a fan shape. Turn on the pressure 
first, and then adjust the nozzle.

Adjusting pressure

Fig. 3

Using High Pressure:
•   Please make sure the trigger released and 

there is not any water spraying. then turn the 
rear part of spray nozzle counterclockwise. 
Squeeze the trigger, the gun will spray water 
with high pressure.

Using Low Pressure:
•   Please make sure the trigger released and 

there is not any water spraying. then turn the 
rear part of spray nozzle clockwise. Squeeze 
the trigger, the gun will spray water with low 
pressure.

 CAUTION: Selection of high or low 
pressure by turning action. The selection 
of the pressure must be carried out with 
the gun in closed position.

Summary of Contents for GRM1020

Page 1: ...www ferm com EN Original instructions 04 GRM1020...

Page 2: ...2 Fig 1 Fig 2 8 6 2 1 3 4 7 9 10 5...

Page 3: ...3 Fig 3 Fig 4 Fig 5 3...

Page 4: ...78 dB A K 3 dB A LWA acoustic power 91 dB A Vibration value 2 5m s2 Contents of packing 1 High pressure cleaner 1 Hose 1 Trigger 1 Lance holder 1 Hose handle screws 1 Lance extension 1 Lance adjustabl...

Page 5: ...y extension cables used must be proportional to their length i e the longer the extension cable the greater the cross section cables with a protection level of IPX5 must be used Position the cleaner A...

Page 6: ...the manufacturer Do not use the machine before you changed them if they are damaged Be care of the danger of the kickback force on the spray assembly when opening the trigger gun and grasp the gun wit...

Page 7: ...the jet against yourself or others in order to clean clothes or footwear Disconnect from the electrical power supply before carrying out user maintenance If the mains cable is damaged it must be repl...

Page 8: ...he cleaner Turn the motor switch to the 0 position Check that the electrical supply voltage and frequency Volts Hz correspond to those specified on the cleaner data plate If the power supply is correc...

Page 9: ...by using the switch on the machine 2 Unplug the unit from the power source 3 Turn off the water supply at the tap 4 Press the trigger of the gun to depressurize the system 5 Disconnect the supply hose...

Page 10: ...oistened in soapy water Do not use any solvents such as petrol alcohol ammonia etc as such substances can damage the plastic parts Lubrication The appliance does not need any extra lubrication Storage...

Page 11: ...11...

Page 12: ...n Position 501094 Filtre 18 502096 valve set 34 TILL37 800796 capacitor 14 501597 main switch 2 501587 water hose 43 502095 wheel 22 TILL 25 503311 detergent spray attachment 17 502299 trigger 42 5222...

Page 13: ...13 13A 13B Exploded view B...

Page 14: ...14...

Page 15: ...ronisk utstyr DA Vi erkl rer under eget ansvar at dette produkt er i overensstemmelse med f lgende standarder og bestemmelser er i overensstemmelse med direktiv 2011 65 EU fra Europa Parlamentet og R...

Page 16: ...www ferm com 2015 FERm B V 1508 28...

Reviews: