background image

6

EN

b)  

Use power tools only with specifically 
designated battery packs. 

Use of any other 

battery packs may create a risk of injury and 
fire.

c)  

When battery pack is not in use, keep it 
away from other metal objects, like paper 
clips, coins, keys, nails, screws or other 
small metal objects, that can make a 
connection from one terminal to another

Shorting the battery terminals together may 
cause burns or a fire.

d)  

Under abusive conditions, liquid may be 
ejected from the battery; avoid contact.
If contact accidentally occurs, flush with 
water. If liquid contacts eyes, additionally 
seek medical help

Liquid ejected from the 

battery may cause irritation or burns.

Service

a)  

Have your power tool serviced by a 
qualified repair person using only identical 
replacement parts.

 

This will ensure that the 

safety of the power tool is maintained.

For the charger

Intended use

Charge only 14.4V or 18.0V MAX 1.5Ah Li-ion 
type rechargeable battery packs. Other types of 
batteries may burst causing personal injury and 
damage.
a)  

The appliance is not to be used by persons 
(including children) with reduced physical, 
sensory or mental capabilities, or lack of 
experience and knowledge, unless they 
have been given supervision or instruction 

b)  

Children being supervised not to play with 
the appliance

c)   Do not recharging non-rechargeable batteries!
d)   During charging, batteries must be placed in 

the well ventilated area!

Residual risks

Even when the power tool is used as 
prescribed it is not possible to eliminate all 
residual risk factors. The following hazards 
may arise in connection with the power tool’s 
construction and design:

a)  

Health defects resulting from vibration 
emission if the power tool is being used 
over longer period of time or not adequately 
managed and properly maintained.

b)  Injuries and damage to property to due to 

broken accessories that are suddenly dashed.

 

Warning!

 This power tool produces an 

electromagnetic field during operation. 
This field may under some circumstances 
interfere with active or passive medical 
implants. To reduce the risk of serious or 
fatal injury, we recommend persons with 
medical implants to consult their 
physician and the medical implant 
manufacturer before operating this 
power tool.

Power cord replacement

If the supply cord is damaged, it must be replaced 
by the manufacturer, its service agent or similarly 
qualified persons in order to avoid a hazard.

Mains plug replacement (UK plug of charger 
only) 

If the molded 3-pin plug attached to the unit is 
damaged and needs replacing, it is important 
that it is correctly destroyed and replaced by 
an approved BS1363/5A fused plug and that 
the following wiring instructions are followed. 
The wires in the mains cable are colored in 
accordance with the following code:
•  blue    neutral
•  brown   live

As the colors of the wires in the mains cable of the 
unit may not correspond to the colored markings 
identifying the terminals in the plug, proceed as 
follows:
•   The wire which is colored blue must be 

connected to the terminal which is marked 
with the letter N or colored black.

•   The wire which is colored brown must be 

connected to the terminal which is marked 
with the letter L or colored red.

Summary of Contents for CDM1113S

Page 1: ...e istruzioni originali 46 vers ttning av bruksanvisning i original 53 Alkuper isten ohjeiden k nn s 59 Oversatt fra orginal veiledning 65 Overs ttelse af den originale brugsanvisning 71 Eredeti haszn...

Page 2: ...2 Fig A 1 3 5 6 3 4 7 12 13 10 11 2 14 9...

Page 3: ...3 Fig D Fig C Fig B 2 5 3 4 6 2 2...

Page 4: ...4 Fig G Fig F Fig E 9 10 11 Hi Low Close Open 8 12 7...

Page 5: ...ronic speed Rotation left right Do not use in rain Indoor use only Class II machine Double insulation You don t need any earthed plug In case of failure the transformer is not dangerous Max temperatur...

Page 6: ...eliminate all residual risk factors The following hazards may arise in connection with the power tool s construction and design a Health defects resulting from vibration emission if the power tool is...

Page 7: ...he tool for the applications mentioned Using the tool for different applications or with different or poorly maintained accessories may significantly increase the exposure level The times when the too...

Page 8: ...it is fully pushed into the slot Plug the charger plug into an electrical outlet and wait for a while The LED indicators on the charger 6 will lighten up and show the charger status LED indicators 6 F...

Page 9: ...direction reversing switch 10 to the middle position to lock the movement of the on off switch It cannot be activated in this position Only lay down the machine when it has stopped running completely...

Page 10: ...y by using a clamp or vice During drilling draw back the drill out of the hole frequently so swarf or drill dust will be removed When drilling in metal Use a metal drill HSS For the best results you s...

Reviews: