InstallatIon InstructIons

skIrted het two pIece toIlet 

Tools Needed

A. Screw Driver  
B. Adjustable Wrench  
C. Marker  
D. Tape Measure  
E. Level  
F. Drill  
G. Toilet Flange 
H. Wax Ring  

I.  T-bolts (2), Nuts (2), 

Washers (2)

J. Flexible Supply Tube

Items Included

K.  Fixing Screws (2),  

Decorative Caps (2),  

Cap Base (2)

L.  Flange Connecting  

“L” Brackets (2)

Note:

 Views in this illustrations are for general representation and may not necessarily define the exact contours of the product.

Remove Old Toilet 

Shut off water supply line to toilet. Flush toilet 
and remove all water from the bowl and tank 
using a sponge. Disconnect the water supply 
from the tank. Remove the tank from bowl, 
use a screw driver and adjustable wrench or 
socket wrench. Loosen toilet bowl flange nuts 
under bolt caps. Remove old bowl by carefully 
lifting it off the floor. Clean flange and plug 
drain with a rag to prevent sewer gas from 
escaping. Replace or repair if required.

Install Connecting “L” Brackets and 

the Wax Ring Seal

1.  Check the rough-in dimension, this is the 

distance from wall to center of outlet. 

2.  Place two new T-connection bolts into the 

slot on the toilet flange. 

3.  Install the connecting “L” brackets onto 

the T-bolts with the flat side toward the 
outside of the flange, adjust the spacing 
on the outside of the bracket to be 8-1/4

"

 

(210mm), now attach the washers and nuts 
to the T-connection bolts and tighten the “L” 
brackets snug and direct to the floor flange. 

4.  Set the wax ring into the outlet between the 

T-connection bolts.

Install Water Closet Base

1.  Place toilet bowl upside down on clean 

surface. 

2.  Install a bead of sealant or plumbers putty 

around the outside foot base on 3 sides. 

3.  Now lift the bowl over the flange and  

lower the bowl into place allowing the “L” 
Brackets to align with the holes on the skirt 
of the toilet bowl.

4.  Firmly push the toilet down seating the bowl 

horn into the wax ring seal. 

5.  Set the bowl in place by gently rocking back 

and forth on the bowl rim. The “L” brackets 
should extend up through the slots on both 
sides of the outlet horn. 

6.  With bowl firmly set, insert fixing screws 

into the seat base, slide the connection 
screw and base into the flange  
connection holes and tighten on both sides 
of the bowl evenly until snug. 

7.  Snap decorative cap over connection  

screw head.

A.        B.           C. 

D.

E.

F.

G.

H.

I.

J.

K.

L.

Flange 

Connection 

Holes

Sealant or  

Plumber Putty

Outlet Horn

Decorative Cap

Connection Screw

Base

Floor 

Outlet 

Flange 

8-1/4

"

 (210mm)

 

          Important

T-Bolts

T-Bolt, 

Nuts & 

Washer

Wax Ring

NOTE: 

If installing the PF9002SWH please disregard the installation instructions included with the tank and use this set of installation instructions

Summary of Contents for PROFLO PF9002SWH

Page 1: ...ide of the flange adjust the spacing on the outside of the bracket to be 8 1 4 210mm now attach the washers and nuts to the T connection bolts and tighten the L brackets snug and direct to the floor f...

Page 2: ...nection bolts first then insert the rubber gasket onto the tank connection bolts and slide them to the base head of the bolt 5 Now insert the connection bolt assemblies into the tank to bowl connectio...

Page 3: ...ightened into place Check hex nut on fill valve to assure it is tight Clean flush valve seat replace flapper if necessary Poor Flush Water level is not set to proper height Low water pressure Obstruct...

Page 4: ...rguson Enterprises Inc 12500 Jefferson Avenue Newport News VA 23602 Attention Consumer Affairs Any shipping charges associated with warranty service must be prepared by the consumer In all cases proof...

Page 5: ...t rieur de la bride ajuster les supports une distance ext rieure de 210 mm 8 1 4 po utiliser les rondelles et les crous sur les boulons de connexion en T et bien serrer les supports en L directement s...

Page 6: ...on du r servoir puis ins rer les rondelles en caoutchouc sur les boulons de connexion du r servoir et les faire glisser jusque sous la t te des boulons 5 Ins rer alors l assemblage de boulons dans les...

Page 7: ...serr e en place V rifier que l crou hexagonal du robinet de remplissage est bien serr V rifier le si ge de la soupape de chasse remplacer le clapet au besoin Chasse insuffisante Le niveau d eau n est...

Page 8: ...rt News VA 23602 l attention du service au consommateur Tous frais d exp dition associ s avec le service de garantie doivent tre pr pay s par le consommateur Dans tous les cas une preuve d achat est r...

Page 9: ...l soporte para que sea de 8 1 4 pul 210 mm Luego fije las tuercas y arandelas a los pernos de conexi n en T y ajuste los soportes en L directo a la brida del suelo 4 Ubique el anillo de cera dentro de...

Page 10: ...o inserte la junta de goma sobe los pernos de conexi n del tanque y desl celos hacia la cabeza base del perno 5 Ahora inserte los juegos de pernos de conex i n en el tanque hacia los orificios de cone...

Page 11: ...ique que la v lvula de descarga est ajustada Inspeccione el perno hexagonal de la v lvula de llenado para asegurarse de que est ajustado Limpie el asiento de la v lvula de llenado reemplace el obturad...

Page 12: ...fairs Atenci n al Consumidor Cualquier gasto de env o asociado con el servicio de garant a deber asumirlo el consumidor En todos los casos se solicitar el comprobante de compra Llame al Servicio al Cl...

Reviews: