Fenwal Controls 35-9 Series Operation And Installation Instructions Manual Download Page 12

Fenwal Controls, Kidde-Fenwal Inc.

400 Main Street

Ashland, MA 01721

Tel: 800-FENWAL-1

Fax: 508-881-7619

 

www.fenwal.com

tekmar is a registered trademark of tekmar Control Systems Ltd. and tekmar Control Systems, Inc.
PIM is a registered  trademark of Kidde-Fenwal Inc. All other trademarks are the property of their respective owners.

This literature is provided for informational purposes only. KIDDE-FENWAL, INC. believes this data to be accurate, but it is published and presented without any guarantee 
or warranty whatsoever. KIDDE-FENWAL, INC. assumes no responsibility for the product's suitability for a particular application. The product must be properly applied to 
work correctly. If you need more information on this product, or if you have a particular problem or question, contact KIDDE-FENWAL, INC., Ashland, MA 01721 USA. 
Telephone: (508) 881-2000.

F-35-2000 Rev AB

©2018 Kidde-Fenwal, Inc.

12 of 12

PIM PART NUMBER

The following image explains the meaning of the various digits in the part number. Use this information to order the correct board.

35 – 9 X X X X X  X X X 

IGNITION TYPE
1 = Direct Spark
2 = Direct Spark with External Relay
6 = Hot Surface Ignition
7 = Proven Hot Surface Ignition

VALVE/FAN CONFIGURATION
0 = Modulating (1-stage)
1 = One Stage
2 = Two Stage
3 = Intermittent Pilot (PV/MV)
4 = One Stage with Auxiliary
5 = Isolated Modulating (1-stage)
6 = Isolated One Stage
7 = Isolated Two Stage

RESERVED
0 = Standard Model
0-9 = Special Feature Assignment

TERMINAL CONFIGURATION
0 = Standard
1 = Pluggable Field Terminal Blocks

BLOWER RELAY
0 = Standard (5A)
1 = High-Current (15A)

FLAME SENSE METHOD
0 = Local Sense
1 = Remote Sense
3 = Dual (Local and Remote)

RESERVED
0 = Standard Model
0-9 = Special Feature Assignment

MODEL CONFIGURATION
0 = North American (C22.2-199) Standard Model
2 = CE (EN298 & 60730) Standard Model
3 = CE (EN298 & 60730) OEM Special Feature Model
5 = North American (60730) Standard Model
6 = North American (60730) OEM Special Feature Model
9 =North American (C22.2-199) OEM Special Feature Model

Description

EXPORT INFORMATION (USA)

Jurisdiction: EAR

Classification: EAR99

This document contains technical data subject to the EAR.

Summary of Contents for 35-9 Series

Page 1: ...ssion testing to be verified after incorporation into end use appliance CSA Design certified to ANSI Z21 20 CAN CSA C22 2 No 199 M99 and ANSI Z21 20 2014 CAN CSA C22 2 No 60730 2 5 14 CE Approved to EN 298 20122 WARNING Installing or operating the product inconsistent with these instructions or specifications could cause serious property damage injury or death Specification Value Input Power Contr...

Page 2: ...sensor types as outlined in the specific appliance manuals Optional 12k Ohm thermistor are available consult factory for details The Inlet Outlet Hi Limit and Vent exhaust stack sensors are directly processed by the PIM The optional System Outdoor and DHW tank sensors are also connected to the PIM but passed through to the tekmar Host Controller which is required to provide those additional featur...

Page 3: ...by the presence of any one or more of the four sources below A heat demand contact closure on the TH field wiring terminals A voltage greater than 0 5Vdc on the analog 0 10Vdc EMS signal input A heat demand present on the DHW field wiring terminals A heat demand from the Host Controller based on the DHW sensor temperature 4 The PIM initializes the Trial for Ignition TFI counter to the programmed n...

Page 4: ...ed number of trials 2 The High Limit sensor is confirmed to read below the High Limit Set Point 3 The blower light off RPM speed is verified modulating type only 4 The gas valve relay contacts are verified open except isolated valve models 5 The Combustion Blower is set to the Ignition light off speed if modulating 6 The Pilot gas valve output is enabled for the trial for ignition time 7 The HV sp...

Page 5: ...d fuse protects the 24 VAC circuits and if configured for direct gas valve power the 24 VAC relay outputs to the gas valves Sensor Inputs The PIM requires an outlet thermistor sensor for burner control and a high limit thermistor sensor for the integrated UL353 high limit function These two thermistors must be independent but co located so they provide similar readings The vent sensor and inlet se...

Page 6: ...eck the cable between the Host Controller and J1 Safety 2 Fault 15 flashes Check gas pressure Verify proper safety switch operation MOUNTING AND WIRING The PIM enclosure is designed to facilitate mounting within a control box by the appliance OEM The PIM is not position sensitive and can be mounted vertically or horizontally The case may be mounted on any surface using four standard 8 sheet metal ...

Page 7: ...te Reset Flow Swit ch DHW TH Thermos t at Host Controller FT Bus B FT Bus A PIM Slave V Boiler Identity Card V in GN D High Limit Sensor Outlet Sensor Air Flow Safety 2 Safety 1 Inlet Sensor Vent Sensor 4 to 20 MA Fan Power 18 VDC Fan GND Flow SEN GND Flow SEN PW 12 VDC PWM Out Flow Sens or Tac homet er To J10 P in 3 To J10 P in 4 24 VAC L1 L2 2 STG MV MV PV RTN Hot Dry Contact Blower System Pump ...

Page 8: ...set Flow Swit ch DHW TH Thermos t at FT Bus B FT Bus A PIM Slave V Boiler Identity Card V in GN D High Limit Sensor Outlet Sensor Air Flow Safety 2 Safety 1 Inlet Sensor Vent Sensor 4 to 20 MA Fan Power 18 VDC Fan GND Flow SEN GND Flow SEN PW 12 VDC PWM Out Flow Sens or Tac homet er To J10 P in 3 To J10 P in 4 24 VAC L1 L2 2 STG MV MV PV RTN Hot Dry Contact Blower System Pump Boiler Pump DHW Pump ...

Page 9: ...Safety 1 return Molex Micro Fit 20 30AWG 2 0A J8 4 Airflow return Molex Micro Fit 20 30AWG 2 0A J8 5 Safety 2 switch Molex Micro Fit 20 30AWG 2 0A J8 6 Safety 2 return Molex Micro Fit 20 30AWG 2 0A J9 1 Inlet Sensor Molex Micro Fit 10K Thermistor J curve J9 2 Vent Sensor Molex Micro Fit 10K Thermistor J curve J9 3 Sensor Common Molex Micro Fit 10K Thermistor J curve J9 4 Sensor Common Molex Micro ...

Page 10: ...Jr 120 240VAC 8A J13 4 L1 supply input Molex Mini Fit Jr 120 240VAC 8A K5 Relay F1 and F2 terminals 250 QC terminals 120 240VAC 15A J14 1 DHW Pump Molex Mini Fit Jr 120 240VAC 5A J14 2 Boiler Pump Molex Mini Fit Jr 120 240VAC 5A J14 3 L1s System Pump Supply Molex Mini Fit Jr 120 240VAC 8A J14 4 System Pump Molex Mini Fit Jr 120 240VAC 5A J14 5 L1 Supply power Molex Mini Fit Jr 120 240VAC 8A J14 6 ...

Page 11: ...DHW Sensor Common 10K Thermistor J curve J2 3 System Supply Sensor 10K Thermistor J curve J2 4 System Sensor Common 10K Thermistor J curve J2 5 Outdoor Sensor 10K Thermistor J curve J2 6 Outdoor Sensor Common 10K Thermistor J curve J2 7 tN4 Communications Network Signal J2 8 0 10Vdc Analog EMS Input 0 10 VDC or 4 20mA J2 9 Common GND J1 1 Alarm Contacts 0 30VAC 2 0A Max Dry contact J1 2 Alarm Cont...

Page 12: ...aning of the various digits in the part number Use this information to order the correct board 35 9 X X X X X X X X IGNITION TYPE 1 Direct Spark 2 Direct Spark with External Relay 6 Hot Surface Ignition 7 Proven Hot Surface Ignition VALVE FAN CONFIGURATION 0 Modulating 1 stage 1 One Stage 2 Two Stage 3 Intermittent Pilot PV MV 4 One Stage with Auxiliary 5 Isolated Modulating 1 stage 6 Isolated One...

Page 13: ...3 SERIES 35 60 61 63 608 SERIES 35 65 66 SERIES 35 9X The object of the declaration described above is in conformity within the relevant union harmonization legislation Gas Appliance Regulation EU 2016 426 Low Voltage Directive 2014 35 EC EMC Directive 2014 30 EC Rohs 2011 65 EU The following harmonized standards and technical specifications have been applied EN298 2012 Automatic Burner Control sy...

Reviews: