3. GENERAL SAFETY RULES

- The lifting tower is an industrial element designed to raise loads vertically, it must NEVER 

be used as a platform elevator for people.
- Only place the lifting tower on firm flat grounds checking it is in vertical position. Do not 

use wedges or any strange elements to balance the hoist.
- Check legs are correctly assembled and secured by their safety pins.
- Never raise a load without first checking it is correctly supported and centred on the appro-

priate lifting tower supports, so the load only acts vertically.
- Never surpass the maximum load capacity indicated on the lifting tower characteristics label 

and on this instruction manual.
- If there is a likelihood of strong wind or gusts, place the lifting tower on the ground and 

secure it with the aid of straps.
- Never fix a strap over a vehicle or any other element which might move.
- Never use a ladder over the lifting tower or lean against it for any kind of work.
- Beware of any kind of projection above the lifting tower like cornices, balconies, luminous 

signs, etc. It is very important to avoid the presence of cables below the lifting tower’s working 

height.
- Never move the lifting tower when the load is raised. It is inadvisable to make any kind of 

movement, even small positioning adjustments.
- Never use the lifting tower over any mobile surface or vehicle.
- Before using the lifting tower, check the cable’s state, which must not present any broken 

threads or compression. NEVER use defective cables and change cable if in doubt. Only use 

steel cable as described on this manual.
- Fix the lever when the load is raised.
- Minimum load for braking function without problems is 25kg. Brake will not function 

without this minimum load.
- Neither grease nor lubricate the winch brake mechanism. Braking disks were greased with a 

special heat and pressure resistant grease. No other products must be used to prevent negative 

influence on brake functioning.
- All sections of the lifting tower must be lowered to transport it.

Summary of Contents for TRC-700

Page 1: ...serie Serial No Instrucciones Instructions Fabricante Manufacturer FENIX Stage S L U FENIX Stage S L U Avda de los Trabajadores 24 Horno de Alcedo 46026 Valencia Spain Tel 34 96 125 08 55 export fenix...

Page 2: ...y the conformity of the product to which this declaration refers as per the following regulations 2006 42 CE Person empowered to compile the technical file and authorised represntative M Julia Niza de...

Page 3: ...DE SEGURIDAD 5 4 INSTRUCCIONES DE USO 6 5 MANTENIMIENTO 8 6 RIESGOS ESPEC FICOS 8 7 SISTEMAS DE PREVENCI N 9 INDEX 1 INTRODUCTION 10 2 GENERAL DATA 10 2 1 Technical data 10 2 2 Applicable regulations...

Page 4: ...TORRE ESTRUCTURAL Modelo TRC 700 Caracter sticas t cnicas Altura m xima 7m Altura m nima 1 40m Carga m xima 600kg Material Acero seg n EN 10305 5 Aluminio EN AW 6082 T6 rea de la base abierta 2 02 x...

Page 5: ...ral en suelo firme y aseg relo con la ayuda de tirantes Nunca fije un tirante sobre un veh culo ni cualquier otro elemento que pueda desplazarse No usar escaleras encima de la torre estructural ni apo...

Page 6: ...do el nivel de burbuja estabilizador L de la base 4 Sacar el contrapeso P de su posici n e insertar en su alojamiento de trabajo N usando el pasador F 5 Montar el per metro de truss al carro C conform...

Page 7: ...pectivos pasadores Se necesitar una carga m nima estable de 90kg en el contrapeso P para la elevaci n de la torre estructural 8 Enganchar el gancho J en el grillete Z del carro C y elevarlo girando la...

Page 8: ...ficiencias en el sistema de frenado o por una mala instalaci n Si deja de funcionar puede provocar un riesgo importante de p rdida de control de la mercanc a elevada y originar golpes y o contusiones...

Page 9: ...a distinto nivel golpes y o contusiones con objetos El riesgo de ca da de objetos a distinto nivel puede prevenirse con la utilizaci n de elementos de seguridad homologados por ejemplo un gatillo de...

Page 10: ...al characteristics Maximum height 7m Minimum height 1 40m Maximum load 600kg Minimum load 25kg Material Steel EN 10305 5 Aluminium EN AW 6082 T6 Open base area 2 02 x 1 77m Closed base area 0 995 x 0...

Page 11: ...lifting tower or lean against it for any kind of work Beware of any kind of projection above the lifting tower like cornices balconies luminous signs etc It is very important to avoid the presence of...

Page 12: ...abilizing bubble level L located at the base 4 Remove the counterweight P from its position and insert it into its working position N using the pin F 5 Assemble the truss perimeter to the sleeveblock...

Page 13: ...pins A minimum stable load of 90kg on the counterweight P will be required for the lifting of the ground support tower 8 Hook the hook J into the shackle Z of the sleeveblock C and lift it by turning...

Page 14: ...anufacturer or an authorised distributor within your territory 6 SPECIFIC RISKS Braking system failure May occur due to braking system deficiencies or bad installation If it stops working it could cau...

Page 15: ...be prevented by using homologated safety elements e g a safety pin which fixes the inner profile of the ground support tower in its working position so the cable does not support load and guaranteeing...

Page 16: ...16...

Page 17: ...17...

Page 18: ...18...

Page 19: ...19 NOTAS NOTES LIFTING TOWERS...

Page 20: ...FENIX Stage S L U FENIX Stage S L U Avda de los Trabajadores 24 Horno de Alcedo 46026 Valencia Espa a Tel 34 96 125 08 55 export fenixstage com www fenixstage com www fenixstage com...

Reviews: