background image

19

NOTAS / NOTES

LIFTING TOWERS

Summary of Contents for NEMESIS 110

Page 1: ...l No Instrucciones Instructions LIFTING TOWERS Fabricante Manufacturer FENIX Stage S L U FENIX Stage S L U Avda de los Trabajadores 24 Horno de Alcedo 46026 Valencia Spain Tel 34 96 125 08 55 export f...

Page 2: ...bility the conformity of the product Name Model Description to which this declaration refers as per the following regulations CE 2006 42 EG Person empowered to compile the technical file and authorise...

Page 3: ...AS DE SEGURIDAD 5 4 INSTRUCCIONES DE USO 6 5 MANTENIMIENTO 7 6 RIESGOS ESPEC FICOS 7 7 SISTEMAS DE PREVENCI N 8 INDEX 1 INTRODUCTION 9 2 GENERAL DATA 9 2 1 Technical data 9 2 2 Applicable regulations...

Page 4: ...AMENTE ESTE MANUAL 2 DATOS GENERALES 2 1 Datos t cnicos Denominaci n TORRE ELEVADORA Modelo NEMESIS 110 Caracter sticas t cnicas Altura m xima 4m Altura m nima 1 55m Carga m xima 110kg Carga m nima 25...

Page 5: ...por encima de la torre elevadora como cornisas balcones letreros luminosos etc Es muy importante evitar la presencia de cables por debajo de la altura de trabajo de la torre elevadora Nunca se debe de...

Page 6: ...nte B en el sentido de las agujas del reloj elevando la carga hasta la posici n deseada Una vez se alcanza la posici n deseada volver a ajustar el pomo de pl stico C En caso de no elevar la torre elev...

Page 7: ...o de su territorio 6 RIESGOS ESPEC FICOS Fallo del sistema de freno Puede producirse por deficiencias en el sistema de frenado o por una mala instalaci n Si deja de funcionar puede provocar un riesgo...

Page 8: ...ra Sobre ca da de objetos a distinto nivel golpes y o contusiones con objetos El riesgo de ca da de objetos a distinto nivel puede prevenirse con la utilizaci n de elementos de seguridad homologados p...

Page 9: ...echnical Data Name LIFTING TOWER Model NEMESIS 110 Technical characteristics Maximum height 4m Minimum height 1 55m Maximum load 80kg Minimum load 25kg Material Steel EN 10305 5 Open base area 1 18 x...

Page 10: ...se a ladder over the lifting tower or lean against it for any kind of work Beware of any kind of projection above the lifting tower like cornices balconies luminous signs etc It is very important to a...

Page 11: ...ise lifting the load until the desired height Once the lifting tower is at the desired height adjust the plastic knob C In case of the lifting tower does not need to be raised to its maximum height it...

Page 12: ...anufacturer or an authorised distributor within your territory 6 SPECIFIC RISKS Braking system failure May occur due to braking system deficien cies or bad installation If it stops working it could ca...

Page 13: ...knocks and or contusions with objects The risk of objects falling to a different level can be prevented by using homologated safety elements e g a safety pin which fixes the inner profile of the lifti...

Page 14: ...14...

Page 15: ...15...

Page 16: ...16...

Page 17: ...17...

Page 18: ...18 NOTAS NOTES LIFTING TOWERS...

Page 19: ...19 NOTAS NOTES LIFTING TOWERS...

Page 20: ...FENIX Stage S L U FENIX Stage S L U Avda de los Trabajadores 24 Horno de Alcedo 46026 Valencia Spain Tel 34 96 125 08 55 export fenixstage com www fenixstage com www fenixstage com...