7
+ -
battery
40 amp fuse
> 1’
Red 12V (+)
Black 12V (-)
Warning!
All user supplied wires connecting
to 12V (+) or 12V (-) must be sized to supply
100% of the maximum current and properly
fused at the power source with the correctly
rated fuse. Avoid routing wires in the
deployment area of the vehicle air bag or
any other potentially hazardous locations.
Electrical Installation
Power Cable Wiring:
Step 1: Install a 40 Amp fuse (customer
supplied) to the end of the red, 12 AWG
wire of the wire harness assembly. Do not
use a circuit breaker or fusible link. Do not
insert the fuse until the opposite end of
the fuse holder is connected to the vehicle
battery.
Step 2: Connect the opposite end of the
fuse to the 12V (+) terminal of the battery.
Do not use more than 1 foot of wire
between the fuse and the battery terminal
to ensure wire protection.
Step 3: Connect the Black, 12 AWG wire to
the vehicle chassis ground.
Step 4: Connect the function wires to
switches, depending on the functions
needed for applications.