Feniex FUSIONGPL FN-4420 Instruction Manual Download Page 7

Feniex Industries, Inc.
1.800.615.8350
 /

 

feniex.com

7

WARNING MODES

Warning modes 0 and 1 can be configured to 

use either the front or rear without activating 

the full lightbar. Modes 2 and 3 can only be 

programmed to have the full bar on or off. 

Programming Mode 0: 

Activate the mode 

by extending the blue/white (front wire) 

or the green/white (rear wire) to a 12v (+) 

source. The front and rear can be used 

together only if the same flash pattern is 

selected.

Programming Mode 1: 

Activate the mode 

by extending the blue/white (front wire) 

or the green/white (rear wire) to a 12v (+) 

source. Overrides Mode 0. Mode 0 needs to 

be activated for Mode 1 to function.

Programming Mode 2 & 3: 

Activate the 

mode by extending the mode wire to a 12v 

(+) source. Mode 2 overrides Modes 0 and 

1. Mode 3 overrides Modes 0, 1 and 2. 

TAKEDOWN

Activate the factory configured takedown 

function by extending the white wire to a 12v 

(+) latching switch.

ALLEY LIGHTS

Activate the factory configured alley 

lights by extending the red/black & 

white wires to 12v (+) latching switches.

Takedown & alley functionality must be specified at time of order. Modules in takedown 

and/or alley positions will only function as such, or flashing takedown/alley. 

No warning 

patterns will be displayed in takedown or alley positions. 

ATTENTION:

WIRING INFORMATION & FUNCTIONS

TAKEDOWN & ALLEY FLASHING

Activate the factory configured takedown flashing function by extending the green wire to 

a 12v (+) latching switch. For dual color models, warning mode 2 will be activated instead 

of the flashing takedown function.

ARROW FUNCTIONS

Activate the arrow functions by 

extending the white/black wire, black/

white wire, or a combination of both to 

12v (+) latching switches.

Arrow functions will override all warning 

modes on all rear-facing modules (not 

including corners). 

ATTENTION:

Summary of Contents for FUSIONGPL FN-4420

Page 1: ...l Accordingly any copyrighted material of Feniex and its licensors contained herein or in the Feniex products described in this Price List may not be copied reproduced distributed merged or modified t...

Page 2: ...ate the previously listed products of Feniex Industries Inc Please read this manual thoroughly before installing or operating your new product in order to prevent any damage or injury Failure to follo...

Page 3: ...UIPMENT DIMENSIONS 44 5 12 13 1 75 3 65 SPECIFICATIONS Voltage 10 18 Volts DC Current Draw Warranty 5 years 15 Amps 20A Fuse 125 ofCircuitLoad Input Power External Fuse 12 VDC Class 1 J595 CT13 J1113...

Page 4: ...ut Slow In Out Fast Combo All Slow 15 16 Combo All Fast Combo Fast Slow FLASH PATTERNS CRUISE PATTERNS Activate Cruise Mode by extending the green wire to a 12v latching switch 1 Apply 12v to the gree...

Page 5: ...arning Mode 2 Overrides Mode 0 1 Warning Mode 3 Overrides Mode 0 1 2 Corner Modules 10 Brightness Overrides Modules 1 2 3 Flash Patterns Steady Burn Overrides Flashing Steady Burn Overrides Flashing F...

Page 6: ...load to the end of the red wire Do not use a circuit breaker or fusible link 2 Connect the opposite end of the fuse to the 12v terminal of the battery Do not use more than 1 foot of wire between the...

Page 7: ...DOWN Activate the factory configured takedown function by extending the white wire to a 12v latching switch ALLEY LIGHTS Activate the factory configured alley lights by extending the red black white w...

Page 8: ...lay Use the 4200 Software to program the desired function of the Fusion 44 Lightbar When the RJ45 Data Link wire is connected to the 4200 Relay this will override any other wire input to the Fusion 44...

Page 9: ...hicle until the bar is snugly mounted Use the included lock nut as a jam nut for extra security Ensure the vehicle s door will close without any interference 5 Drill and secure the bracket to the vehi...