Feniex FUSIONGPL FN-4420 Instruction Manual Download Page 4

Feniex Industries, Inc.
1.800.615.8350
 /

 

feniex.com

4

1

All-On

2

3

4

5

6

7

8

Single Slow

Single Fast

Single Slow - Alternating

Single Fast - Alternating

Single Slow Corners - Alter.

Single Fast Corners - Alter.

Attack Pattern

*Single & Dual Color Modes

1

Cluster Pattern

2

3

4

5

6

7

8

9

10

11

12

13

14

Attack Pattern

Night Ride Pattern

Half-Half [Slow]

Half-Half [Fast]

One-One [Slow]

One-One [Fast]

Two-Two [Slow]

Two-Two [Fast]

All-On [Fast]

All-On [Slow]

In-Out [Slow]

In-Out [Fast]

Combo: All Slow

15

16

Combo: All Fast

Combo: Fast & Slow

FLASH PATTERNS

CRUISE PATTERNS

Activate Cruise Mode by extending the green 

wire to a 12v (+) latching switch.

1.

 Apply 12v (+) to the green wire. 

2. 

Apply 12v (+) (momentary) to the red/white 

wire to advance the pattern of the cruise mode. 

FLASH PATTERNS

1

Front Modules

2

3

4

5

Front & Side Modules (no alley)

Front, Side (no alley), & 

Rear/Arrow Modules

Side & Rear/Arrow Modules

Rear/Arrow Modules

FLOOD PATTERNS

Activate Flood Mode by extending the green/

black wire to a 12v (+) latching switch.

To activate flood mode, use the red/white pattern 

change wire to select the desired flood mode.

Summary of Contents for FUSIONGPL FN-4420

Page 1: ...l Accordingly any copyrighted material of Feniex and its licensors contained herein or in the Feniex products described in this Price List may not be copied reproduced distributed merged or modified t...

Page 2: ...ate the previously listed products of Feniex Industries Inc Please read this manual thoroughly before installing or operating your new product in order to prevent any damage or injury Failure to follo...

Page 3: ...UIPMENT DIMENSIONS 44 5 12 13 1 75 3 65 SPECIFICATIONS Voltage 10 18 Volts DC Current Draw Warranty 5 years 15 Amps 20A Fuse 125 ofCircuitLoad Input Power External Fuse 12 VDC Class 1 J595 CT13 J1113...

Page 4: ...ut Slow In Out Fast Combo All Slow 15 16 Combo All Fast Combo Fast Slow FLASH PATTERNS CRUISE PATTERNS Activate Cruise Mode by extending the green wire to a 12v latching switch 1 Apply 12v to the gree...

Page 5: ...arning Mode 2 Overrides Mode 0 1 Warning Mode 3 Overrides Mode 0 1 2 Corner Modules 10 Brightness Overrides Modules 1 2 3 Flash Patterns Steady Burn Overrides Flashing Steady Burn Overrides Flashing F...

Page 6: ...load to the end of the red wire Do not use a circuit breaker or fusible link 2 Connect the opposite end of the fuse to the 12v terminal of the battery Do not use more than 1 foot of wire between the...

Page 7: ...DOWN Activate the factory configured takedown function by extending the white wire to a 12v latching switch ALLEY LIGHTS Activate the factory configured alley lights by extending the red black white w...

Page 8: ...lay Use the 4200 Software to program the desired function of the Fusion 44 Lightbar When the RJ45 Data Link wire is connected to the 4200 Relay this will override any other wire input to the Fusion 44...

Page 9: ...hicle until the bar is snugly mounted Use the included lock nut as a jam nut for extra security Ensure the vehicle s door will close without any interference 5 Drill and secure the bracket to the vehi...

Reviews: