9. Gas
9.1 General safety rules for the use of liquid gas
facilities
The gas operation pressure is
30 mbar.
(Picture may vary somewhat from the equipment
on your camper!)
1
Connections on gas pressure regu-
lators are screwed on counterclock-
wise.
Inspection of the gas facilities
•
Have the gas facilities checked by an expert
before the first use.
•
The gas facilities should be inspected by
an expert every two years. This inspection
should be documented on the inspection cer-
tificate in accordance with the German Asso
-
ciation of Gas and Water Experts, worksheet
G 607, and EN 1949.
•
Regulator knobs, hoses and waste gas out-
lets should also be inspected.
•
We recommend that you replace the safety
regulator knob and hose pipes no later than
every 10 years.
•
The owner/operator is responsible for arrang-
ing the inspection. This also applies for vehi-
cles that are not licensed to drive on public
roads.
Installations and modifications
•
Located behind the kitchen drawer.
•
Installations and modifications may only be
conducted by an expert.
•
Only devices with a uniform inlet pressure of
30 mbar may be operated.
• Any change in the gas facilities requires a new
inspection by an expert and written documen-
tation of this inspection.
Regulator knobs and valves
•
Only use those regulator knobs custom-made
for vehicles, with a safety valve
j
. Other
regulator knobs are not permissible in accor-
dance with the German Association of Gas
and Water Experts, worksheet G 607, and
EN 1949. They are not sufficient to tolerate
the immense strain.