TROUBLESHOOTING

ISSUE

PROBLEM

TROUBLESHOOT

The device does not function

(i.e. the LED light is not on)

The AC adapter is not connected  
to the mains   

Connect device to the mains power

Mains power failure

Check household fuse box

The AC adapter is not connected to the Control 
Unit

Follow Step 15

 on Installation Guide

The digital mixer is not working

Follow Step 14

 on Installation Guide

The water temperature does not match 

the indicated display

Hot and cold water connections reversed

Check connections are correct

Hot or cold water stop valve closed or only half 
opened

Fully open both stop valves

Kink in supply hose

Check connection hoses

Connecting pipe blocked

Flush pipes and clean filter

No hot water

Check hot water tank and instantaneous

 

connections

Temperature sensor defect

Carry out function «Diagnostic Test»

in User Guide

Difference in supply pressure between hot

 

and cold water is greater than 100kPa

Balance pressure to eliminate difference

Constant flow of water

Unit will not turn off

Carry out function «Diagnostic Test»

in User Guide

The water shuts off before maximum run 

time has been reached

Flow sensor is defective 

Carry out function «Diagnostic Test»

in User Guide

The device is working but has

no water flow

Motors are not calibrated

Carry out function «Diagnostic Test»

in User Guide

Stop valves closed

Open stop valves fully

No water supply

Restore water supply

Kink in supply hose

Check connection hoses

Interface flashes green

Cleaning mode active

Wait 45 seconds or press the digital mixer 
to cancel

The Digital Control Unit is damp or wet

Inlet and outlets of the digital mixer are 
not properly sealed

Inspect all connections, reseal if necessary

The Control Unit does not respond to 

temperature and flow adjustment*

The interface elements  
are connected incorrectly

Follow Step 14

 on Installation Guide

The interface is defective

Carry out function «Diagnostic Test»

in User Guide

The knob is not running smoothly

Remove and clean knob

Summary of Contents for TATE SMARTFLOW

Page 1: ...1 TATE SMARTFLOW DIGITAL SHOWER MIXER INSTALLATION GUIDE INSTALLATION GUIDE TATE Smartflow Digital Shower Mixer...

Page 2: ...2 FELTON...

Page 3: ...R INSTALLATION GUIDE Control Unit Installation 7 Measurements 5 Tools Required 4 Notice 4 Scope of Application 6 Digital Mixer Installation 11 Operational Test 17 CONTENTS Connecting the Flow Controll...

Page 4: ...HOCK ELECTRICAL INSTALLATION Before opening the housing the mains connection must be switched off Work on electrical parts and connections must be carried out by qualified electrician Country specific...

Page 5: ...rol Mounting Tube 4 Cable Tie 5 Control Sleeve 8 Foam Seal 6 Control Wheel 7 Control Housing 2 Screw MEASUREMENTS 155mm 55mm 115mm 1 Temperature Control Unit 4 Set of Screws 2x 5x50mm 2 12V AC Adapter...

Page 6: ...ended B Wall Mounted TATE SMARTFLOW DIGITAL SHOWER MIXER Cable length 6m max Handset outlet Cold in Hot in Note The wheel can be tted anywhere in the showering area Note The Digital Mixer must not be...

Page 7: ...e is installed in conduit for ease of maintenance The Control Tube can be reduced in length if required by cutting along the cutting slot see Fig 2 Prepare a 30 32mm hole in the finished wall deck or...

Page 8: ...astic sleeve leave this on until later in the installation Control Mounting Tube Data Cable Push the Control Mounting Tube into the hole until the front flange sits against the wall Apply a silicone b...

Page 9: ...is aligned with the Plastic Mounting Tube This tightens the lugs on the inside of the wall Tighten until there is no rotation of the Control Housing 6 7 Pull the red strip to release the connector fr...

Page 10: ...10 FELTON 8 Thread in the cable and fit the Control Wheel onto the Housing Fit the Control Sleeve onto the Control Wheel Ensure that you fit the Control Sleeve in the correct orientation SIDE VIEW...

Page 11: ...SHOWER MIXER INSTALLATION GUIDE 10 Inside the Temperature Control Unit 9 Remove the cover DIGITAL MIXER INSTALLATION Outlet Hot Cold Inlets Fixing holes Fixing hole Cover retaining holes Transformer 1...

Page 12: ...tal Mixer 99mm 1 Mark fixing holes 56mm 2 Drill fixing holes 99mm 56mm 5mm 3 Install the Digital Mixer If installed vertically use orientation shown 99mm 1 Mark fixing holes 56mm If installed vertical...

Page 13: ...s and filters to the water supply feed Large retaining bolt A Connect the brass adaptors into the flexi hoses B Fit both flexi hoses with the brass adaptor on firmly into the unit box C Fit the large...

Page 14: ...o the Digital Mixer and fit the short retaining bolt with torx screw driver supplied ADVICE Push in firmly 14 Connect the Data Cable coming from the Control Unit Use the large 6 pin connector and push...

Page 15: ...WER MIXER INSTALLATION GUIDE 15 Connect the power cable coming from the transformer Use the connector and push firmly into the socket Feed the cable through the guide slot in the front of the Digital...

Page 16: ...ssioning Please see User Guide IMPORTANT Electrical supply must be installed by a qualified electrician if required Power cable connection IMPORTANT Fit cables into slots to allow cover to properly cl...

Page 17: ...the unit and plumbing for leaks Once the plumbing is confirmed to be water tight connect the power supply and conduct the operational test below OPERATIONAL TEST Digital Mixer with Flow Control Unit i...

Page 18: ...tic Test in User Guide Difference in supply pressure between hot and cold water is greater than 100kPa Balance pressure to eliminate difference Constant flow of water Unit will not turn off Carry out...

Page 19: ...does not cover any damage to product due to abuse negligence or improper installation This warranty is given on the understanding that the product is installed by a registered plumber and operated ac...

Page 20: ...felton industries limited FeltonIndustriesLimited feltonltd feltonltd feltontapware FELTON INDUSTRIES LTD 8 Farmhouse Lane St Johns Auckland 1072 w w w felton co nz Find us on Social Media 150322EI...

Reviews: