Page 10
Important
• Before operating the table, the initialization procedure
must be completed. See Step 11 on page 8.
General operation
• Move the table up or down by pressing UP
s
or DOWN
t
until the
worksurface reaches the desired height.
• The table will continue to move up or down until you release the
button or until the maximum or minimum height is reached.
Memory stop positions
• Up to three memory stop positions can be used to save specific
heights of the worksurface. To set a specific position:
— Raise or lower the table to the position you want to save.
— The display on the digital keypad shows the worksurface height.
— Press and release the
S
button. Then press the desired memory
button (
1
,
2
or
3
) within the next 3 seconds.
— Position 1, 2 or 3 is now saved.
• To move the worksurface to a memory stop position:
— Press and hold the desired memory button (
1
,
2
or
3
).
— The worksurface will move to the saved position and then stop.
— If you release the memory button before the saved position is
reached, table movement will stop.
Lower stop position
• To set the lower stop position (the minimum height of the table):
— Raise or lower the table to the desired minimum height.
— Press and hold
S
, then press and hold
1
. Continue to press both
buttons for about 3 seconds.
— The letter “L” appears on the display. This means the minimum
height of the table is locked at its current position.
— Release both buttons.
— If there is a memory stop position lower than the new lower stop
position, that memory stop will be erased.
• To erase the lower stop position:
— With the table at its lower stop position, press and hold
S
, then
press and hold
2
. Continue to press both buttons for about
3 seconds.
— The letter “C” appears on the display, indicating the lower stop
position has been erased.
— Release both buttons.
VictoryLX 3-leg
Operation
UP
button
memory buttons
digital
display
DOWN
button
SET
button
Upper stop position
• To set the upper stop position (the maximum height of the table):
— Raise or lower the table to the desired maximum height.
— Press and hold
S
, then press and hold
3
. Continue to press both
buttons for about 3 seconds.
— The letter “L” appears on the display. This means the maximum
height of the table is locked at its current position.
— Release both buttons.
— If there is a memory stop position higher than the new upper stop
position, that memory stop will be erased.
• To erase the upper stop position:
— With the table at its upper stop position, press and hold
S
, then
press and hold
2
. Continue to press both buttons for about
3 seconds.
— The letter “C” appears on the display, indicating the upper stop
position has been erased.
— Release both buttons.
Adjusting the height readout
• To set the display height of the table to account for different
worksurface thicknesses:
— Move the table to the lowest position by pressing the DOWN
t
button.
— Measure and record the height of the top of the worksurface.
— Press and hold
S
until the first LED number blinks.
— Press and hold UP
s
or DOWN
t
, changing the number in the first
LED position to the number desired.
— Press and hold
S
again until the second LED number blinks.
— Press and hold UP
s
or DOWN
t
, changing the number in the
second LED position to the number desired.
— Press and hold
S
again until the third LED number blinks.
— Press and hold UP
s
or DOWN
t
, changing the number in the
third LED position to the number desired.
— Finish setting this new height readout by pressing
S
one more time.
• In inch format, the minimum adjustable amount (third digit) is 0.5".
(The third digit will be either 0 or 5.) In centimeter format, the
minimum adjustable amount (third digit) is 1 cm. (The third digit will
be 0 through 9.)