background image

Assembly instructions

Victory

LX 3-Leg

Model # 3V-LX-C4848-24-___
Model # 3V-LX-C4848-30-___
Model # 3V-LX-C4836-24-___
Model # 3V-LX-C4836-30-___
Model # 3V-LX-C3636-24-___
Model # 3V-LX-C3636-30-___

___ = SLV, BLK or WHT

Electric height adjustable table base

Summary of Contents for ESI Victory 3V-LX-C3636-24 Series

Page 1: ...Victory LX 3 Leg Model 3V LX C4848 24 ___ Model 3V LX C4848 30 ___ Model 3V LX C4836 24 ___ Model 3V LX C4836 30 ___ Model 3V LX C3636 24 ___ Model 3V LX C3636 30 ___ ___ SLV BLK or WHT Electric height adjustable table base ...

Page 2: ... Use power drill on self tapping screws only Always check that screws used to attach components to the worksurface are not too long for the thickness of the table table thickness top supports 2 motor cable locking clips 4 center leg bracket 1 center bracket screws M6x15 socket cap 8 cord clips 10 feet screws M3 5x16 2 Phillips flat head 10 cam locks 3 with cotter pin outer legs with motor 2 center...

Page 3: ...t screws on each of the frame segments Attach the center leg bracket to the left frame segment The longer section of the cross channel at the open end should be at the top toward the rear of the table Align the 90 120 or 180 holes on the bracket with the two holes on the ends of each channel as shown This example is a 120 table Adjust the channels as necessary to align the holes Secure the bracket...

Page 4: ... cross channels see below Position the rear cross channels 6 5 or 9 5 from the rear edge of the table depending on table depth 6 5 for tables 24 deep and 9 5 for tables 30 deep The center leg bracket should be centered under the angle of the table top If it is not check that the frame is positioned according to the diagram below Tighten all set screws dotted line 30 depth tighten all set screws ce...

Page 5: ...he cam lock is installed rotate its lever arm toward the leg until the lever is horizontal This locks the leg in place Install the cotter pin to secure the cam lock Check to be sure each leg is securely locked in position CAUTION The cam locks must be in the locked position at all times to secure the legs in place Step 4 attach frame to table Use the M4 8X22 2 Phillips round head screws to secure ...

Page 6: ...sing into the notches Then push the protrusions back into the narrower part of the notches Install the remaining cam lock With the lever arm upward insert the long end of the cam lock first as shown After the cam lock is installed rotate its lever arm toward the leg until the lever is horizontal to lock the leg in place Install the remaining cotter pin to secure the cam lock Check to be sure each ...

Page 7: ...l keypad on the left or right side of the table according to user preference Align the top of the keypad with the edge of the table so that the controls will be easily accessible in the expanded position To prevent accidental damage when not in use the keypad may be pushed in under the table Step 9 attach control unit Position the control unit near the back of the table or between the cross channe...

Page 8: ...secure and check that the control unit is securely attached to the worksurface If problems continue call ESI Customer Service 800 833 3746 NOTICE The table must be re initialized when power is restored Step 13 use the motor cable locking clips and cord clips to secure cables and cords IMPORTANT The cables and cords must not dangle under the table where they may present a hazard to the user or be a...

Page 9: ...he feet and center leg to level the worksurface Plug the power cord into an AC outlet Re initialize the system See Step 11 on page 8 IMPORTANT Be sure there are no obstacles under the table that would prevent it from reaching its lowest position See the following pages for operating procedures NOTICE Whenever the unit is unplugged or the power is cut the table must be re initialized VictoryLX 3 le...

Page 10: ...cating the lower stop position has been erased Release both buttons VictoryLX 3 leg Operation UP button memory buttons digital display DOWN button SET button Upper stop position To set the upper stop position the maximum height of the table Raise or lower the table to the desired maximum height Press and hold S then press and hold 3 Continue to press both buttons for about 3 seconds The letter L a...

Page 11: ...r ON to normalize communication 2 Table is tilted straighten table or wait one minute before operating table IMPORTANT The table should be re initialized after every 1 000 cycles every six months or if power is cut or cable is unplugged accidentally When re initializing be sure there are no obstacles under the table that would prevent it from reaching its lowest position VictoryLX 3 leg Operation ...

Page 12: ...F MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO ONE YEAR FROM THE DATE OF ORIGINAL RETAIL PURCHASE ESI s sole obligation under this warranty or any implied warranty and the purchaser s sole remedy is limited to the repair or replacement at ESI s option of the product or any defective part Costs such as installation labor fees or express shipping incurred due to rep...

Reviews: