Page 10
TriumphLX Operation
Reset the table to factory settings (re-initialization)
• To reset the table to factory settings, re-initialize the control unit using the keypad.
— Be sure there are no obstacles under the table that would prevent it from reaching
its lowest position.
— Press and hold the UP
▲
and DOWN
▼
buttons simultaneously for more than 3
seconds. The legs will begin to move down at half speed of normal operation.
— Continue to hold the UP
▲
and DOWN
▼
buttons.
— The legs will move down to the lowest position, then rebound
1
/
16
" to
3
/
16
" (2mm to
5mm) and stop.
— Release the UP
▲
and DOWN
▼
buttons at the same time. This completes the
re-initialization procedure.
Adjust gyro anti-collision sensitivity
• The default anti-collision sensitivity is G-1. To increase or decrease the sensitivity of the
table to obstacles in the path of its movement:
— Press and hold the
S
button for more than 5 seconds. The display shows “–––”.
— Release
S
and, within 3 seconds, press the
3
button. The display shows “G–X”, where
X is a number from 0 to 4.
— Press the UP
▲
or DOWN
▼
button to increase or decrease the gyro sensitivity
level. There are five levels of sensitivity: “G–0”, “G–1”, “G–2”, “G–3” and “G–4”.
“G–4” indicates the highest sensitivity and “G–0” is no gyro sensitivity.
— Press and hold the
S
button for more than 3 seconds. This completes the adjustment.
Error codes
If one or more motors are changed in a system, the table
must be reset to factory settings.
If the legs do not move when general operation is
attempted, the gyro sensitivity adjustment may be
too high.
Error Code
Description
Troubleshooting
E01
Leg malfunction
1. Check that the leg cables are securely plugged into the leg and control unit.
2. Inner parts of leg are broken. Replace the leg.
E03
Table top overload
1. Remove some weight from the table.
E04
Control unit malfunction
1. Re-initialize the system.
E05
Keypad button stuck
1. Toggle the button to restore normal function.
2. Replace the keypad if the button remains stuck.
E06
Communication interruption
1. Check the cable connection between the keypad and control unit. Verify that the cable is
securely plugged into the control unit.
2. If the problem is not resolved, replace the keypad or control unit.
E12
Gyro error
1. Communication is abnormal; power
ON
to normalize communication.
2. Table is tilted; straighten table or wait one minute before operating table.
IMPORTANT: The table should be re-initialized after every 1,000 cycles; every six months; or if power is cut or cable is unplugged accidentally.
When re-initializing, be sure there are no obstacles under the table that would prevent it from reaching its lowest position