background image

Assembly instructions

Triumph

LX

Model # 2T-LX-C36-24-___

Model # 2T-LX-C36-30-___
Model # 2T-LX-C48-24-___

Model # 2T-LX-C48-30-___

___ = SLV, BLK or WHT

Electric height adjustable table base

Summary of Contents for 2T-LX-C36-24-BLK

Page 1: ...Assembly instructions Triumph LX Model 2T LX C36 24 ___ Model 2T LX C36 30 ___ Model 2T LX C48 24 ___ Model 2T LX C48 30 ___ ___ SLV BLK or WHT Electric height adjustable table base ...

Page 2: ...driver Phillips 1 and 2 bits caution When drilling holes for the wood screws guard against drilling through the top of the worksurface Always check that screws used to attach components to the worksurface are not too long for the thickness of the surface work surface legs with motor 2 frame C36 or C48 1 C48 C36 frame screws digital keypad 1 M3x20 1 Phillips round head 3 motor cable 2 5mm Allen key...

Page 3: ...deep position the rear cross channel 6 5 from the rear edge of the table With 30 0 tables position the rear cross channel 9 5 from the rear edge of the table These positions of the frame will align the rear of the feet to the rear of the table when the feet are installed in step 4 Step 2 screw frame to table Use the M4 8X22 2 Phillips round head screws Both the C36 frame and C48 frame require 12 s...

Page 4: ...h leg under the frame support as shown Install the cam lock With the lever arm upward insert the long end of the cam lock first as shown After the cam lock is installed rotate its lever arm toward the leg until the lever is horizontal This locks the leg in place Install the cotter pin to secure the cam lock Check to be sure each leg is securely locked in position WARNING The cam locks must be in t...

Page 5: ...e keypad can reach the control unit and the motor cables can extend from the control unit to both motors Attach the control unit using the two M5x15 2 Phillips round head screws Step 7 make cable and cord connections Connect the cable from the digital keypad to one of the end ports on the control unit as shown Connect the motor cables to the ports on top of the control unit and to the short cable ...

Page 6: ...ress the UP and DOWN buttons individually to test operation End your test with the legs lowered Unplug the power cord If there are problems with operation check that all cable and cord connections are secure If problems continue call ESI Customer Service 800 833 3746 Step 10 use cord clips to secure cables and cords IMPORTANT The cables and cords must not dangle under the table where they may pres...

Page 7: ... to ensure free unobstructed movement If necessary adjust the leveling glides on the feet to level the worksurface Plug the power cord into an AC outlet Re initialize the system See Step 8 on page 6 IMPORTANT Be sure there are no obstacles under the table that would prevent it from reaching its lowest position See the following pages for operating procedures NOTE Whenever the unit is unplugged or ...

Page 8: ... worksurface to a memory stop position Press and hold the desired memory button 1 2 or 3 The worksurface will move to the saved position and then stop Lower stop position To set the lower stop position the minimum height of the table Raise or lower the table to the desired minimum height Press and hold S then press and hold 1 Continue to press both buttons for about 3 seconds The letter L appears ...

Page 9: ...face thicknesses Move the table to the lowest position by pressing the DOWN button Measure and record the height of the top of the worksurface Press and hold S until the first LED number blinks Press and hold UP or DOWN changing the number in the first LED position to the number desired Press and hold S again until the second LED number blinks Press and hold UP or DOWN changing the number in the s...

Page 10: ...0 is no gyro sensitivity Press and hold the S button for more than 3 seconds This completes the adjustment Error codes If one or more motors are changed in a system the table must be reset to factory settings If the legs do not move when general operation is attempted the gyro sensitivity adjustment may be too high Error Code Description Troubleshooting E01 Leg malfunction 1 Check that the leg cab...

Page 11: ......

Page 12: ...ranty or any implied warranty and the purchaser s sole remedy is limited to the repair or replacement at ESI s option of the product or any defective part Costs such as installation labor fees or express shipping incurred due to replacement of products are not covered under warranty IN NO EVENT SHALL FELLOWES ITS AFFILIATES SUBSIDIARIES RELATED ENTITIES OR THEIR RESPECTIVE OFFICERS DIRECTORS OR EM...

Reviews: