FELLER ENGINEERING MCS Manual Download Page 3

Uncompromisingly

simple and intuitive

4

5

All func�ons are clearly dis-
played in the naviga�on
menu and can be called up by
one click. The naviga�on
menu can be accessed via the
menu icon

.

The func�ons are divided into the areas of
mold-specific setup, opera�on and controller-
specific se�ngs in a user-oriented manner.

The menu bar is always visi-
ble and allows access at any
�me to the main func�ons
such as naviga�on

, main

view

and

switching

outputs on and off

as well

as ac�va�ng standby

.

In the main view

all zones

are

displayed

with

the

relevant process values. Via
the menu icon

you can

access all func�ons and
se�ngs the controller has.

A clear and well-arranged structure of the user interface with
icons and clearly visible touch fields (white) ensure intui�ve and
self-explanatory opera�on. A green background means that a
func�on is selected.

A brief descrip�on of each func�on can be
called up by touching the icon. This avoids
tedious searching in the opera�ng instruc�ons.

The operator can determine from numerous
process values those that are to be shown in the
zone display. Up to 8 values can be displayed
per zone.

A brief descrip�on of

each func�on can be

called up by touching the icon

.

This avoids

tedious searching in the manual.

The quick start guides you through the essen�al
se�ngs (groups, opera�ng mode and setpoints)
to put the controller into opera�on quickly and
safely when changing molds.

Smart navigation

Operator guidance

Individual zone display

Explanation at the touch of a

button

Quick start

Clear screen layout with intuitive design

1

2

3

4

1

2

3

Summary of Contents for MCS

Page 1: ...MCS Hot Runner Controller Precise and Convenient Process Control www fellereng de en Uncompromisingly simple and intuitive...

Page 2: ...t runner controllers is capa ble of supplying up to 16A A special assignment of the outputs for nozzles or manifolds is not necessary Tiltable display Service friendly design 3 sided LED light band Po...

Page 3: ...er interface with icons and clearly visible touch fields white ensure intui ve and self explanatory opera on A green background means that a func on is selected A brief descrip on of each func on can...

Page 4: ...rm an in depth analysis based on the data The mold check tests the wiring of sensors and heaters and is par cularly useful when se ng up a new mold The mold check detects swapped sensors heaters or co...

Page 5: ......

Page 6: ...r polarity sensor voltage heater current load short circuit heater interrup on temperature devia ons output level fault current fuse triac relay Timer switch outputs on and off automa cally at specifi...

Page 7: ...reen In the event of a warning or alarm the display changes to yellow or red The controller can also be switched to standby via an external control signal Fast and precise control High quality electro...

Page 8: ...oup zones Mold check Gentle heating Sequential heatiing Boost Standby Combined heating Controller network up to 360 zones MCS MCS e Overvoltage protection for sensors Star Delta switching User levels...

Page 9: ...able electrically insulated per zone 1x hea ng 230V AC switching Control me phase angle pulse package 10 ms at 50 Hz 8 3 ms at 60 Hz Current per zone max 16 A with 80 switch on dura on per zone Minimu...

Page 10: ...Dimensions 18 19 Tabletop devices 30 36 Zones Large units on rollers 42 to 120 zones...

Page 11: ...FELLER ENGINEERING GmbH Carl Zeiss Str 14 63322 R dermark Germany Tel 49 0 6074 8949 0 Fax 49 0 6074 8949 49 www fellereng de en E Mail info fellereng de...

Reviews: