background image

NEW FOB SETUP & sync

Pairing is only necessary the first time you use the system and not 

necessary before each boating trip. Pairing is the first-time-use 

procedure of synchronizing your FOBs unique IDs with your HUB to 

allow the two to connect wirelessly.

3

sec

3

sec

Press and hold 

the button on 

your HUB.

The HUB starts 

flashing blue and 

gives a sound 

signal indicating 

Pairing Mode.

Press and hold 

the button on 

your FOB

The HUB will give a 

sound signal and a 

green light to indicate 

a successful pairing.

The HUB can store the ID of up to 20 

unique FOBs at any given time. If pairing 

more than 20 FOBs the system will start 

overwriting the first stored FOB IDs. The 

HUB will continue to remember the FOB 

IDs even though the unit lose power.

Smart FOB memory

To use a particular FOB on multiple boats, 

you need to repair the FOB for each time 

the FOB is transferred to the new vessel. 

The FOB only remember its last paired 

HUB, this is to prevent it from connecting 

to more than one HUB at the time.

One FOB, multiple boats

FOB MISSING - OVERRIDE

If you have lost your FOB or if it’s out of battery, you can always 

override the system. Remember that when you override the 

system you will NOT be protected in a man overboard situation.

In the unlikely event that the MOB+ Sys-

tem stops functioning. Unplug the xHUB 

and plug the emergency cap into the 

cable to be able to drive your boat. The 

emergency cap is located on the cable 

supplied with the MOB+ xHUB.

Emergency Cap

Override Mode automatically times out 

after 8h and shuts down your engine(s) 

to prevent engine start if the boat is 

left unobserved. After time-out the 

Override Mode can be reactivated as 

shown above.

8h Time-Out

10

sec

No FOB available

Press and hold 

the button on 

your HUB for 10 

seconds

Success! 

You can now start 

your engine(s)

Summary of Contents for MOB Plus

Page 1: ...USER GUIDE MOB MULTIFOB FELL Marine 2018 Designs prices and features subject to change To read the full user manual see video tutorials and other useful information visit WWW FELLMARINE COM...

Page 2: ...UP TO 4 PEOPLE ONBOARD BE PROTECTED IN ALL CONDITIONS INNOVATING BOATING SAFETY xFOB xHUB YOUR PERSONAL LIFEGUARD 1972 Corded Lanyard Falling overboard is one of the most likely cause of death while...

Page 3: ...s the STOP FOB Successive connections automatically becomes ALARM FOBs Universal FOBs Use any universal xFOB with the same xHUB system just pair and connect FOB Status Indication The xHUB has four lig...

Page 4: ...gain to reconnect The Pilot FOB acts as a stop button to shut down the engine s at any time While the Pilot FOB is connected click the button on the FOB to activate stop The same stop function can be...

Page 5: ...boats you need to repair the FOB for each time the FOB is transferred to the new vessel The FOB only remember its last paired HUB this is to prevent it from connecting to more than one HUB at the time...

Page 6: ...Connected passengers Connect anyone Disconnecting any Alarm FOB will not shut down the engine s Connect or disconnect an Alarm FOB at any time while the Pilot FOB is connected Disconnect Alarm FOBs Pi...

Page 7: ...OB Disengage Alarm MOB Mode automatically times out after 2h shuts down your engine s This is to prevent engine start if the boat is left unobserved after leaving the boat without disconnecting the xF...

Page 8: ...FOB xBAND xtag Testing submersion FOB range battery indication emergency stop waterproof battery type You can at any given time when connected use the button on the HUB or FOB as an emergency engine...

Page 9: ...ure range From 15 C 5 F to 55 C 131 F Voltage Source Coin Cell Battery 3V nominal Power consumption 0 3 A in sleep 0 00033 W 30 mA in active mode 0 098W Battery life 300 hours continous usage Wireless...

Reviews: