Felder RL 250 User Manual Download Page 6

6

!

Dust Extractor

RL 250/RL 300

1.2 Information about the manual

This manual describes how to operate the machine 

properly and safely. Be sure to follow the safety tips and 

instructions stated here as well as any local accident 

prevention regulations and general safety regulations.

Before beginning any work on the machine, ensure that 

the manual, in particular the chapter entitled “Safety” 

and the respective safety guidelines, has been read in its 

entirety and fully understood. This manual is an integral 

part of the machine and must therefore be kept in the 

direct vicinity of the machine and be accessible at all 

times. If the machine is sold, rented, lent or otherwise 

transferred to another party, the manual must accompany 

the machine.

Attention! This operating manual contains general guidelines on how to transport, set up, operate and 

maintain the filter system.

The information contained in this manual is based on 

practical experience acquired over many years. It is 

recommended to comply exactly with the technical speci-

fications to guarantee the best possible results and a safe 

operation of the machine. Read this operating manual 

carefully and keep it in a safe place. If you have any 

questions or are unclear about the instructions, please do 

not hesitate to contact us. Please have the machine serial 

number at hand when you contact us. 

•   This operating manual is designed for english spoken 

technicians.

•   If the instructions in this operating manual are not 

observed, the guarantee claim is null and void. 

•   The filter system may only be operated, maintained 

and put into operation by personnel who have read 

and understood the operating manual and are famil-

iar with the applicable working safety and accident 

prevention regulations. 

•   Keep this operating manual close at hand and en-

sure it is easily accessible to every operator. 

•   In addition to the operating manual, comply with 

the local applicable accident prevention rules and 

regulations. 

Attention! This system was manufactured according to state-of-the-art technology and the safety standards 

in force. This does not, however, exclude the risk of bodily injury, system damage or other material dam-

ages when used. 

 

The system may only be used if it is technically defect-free and if the instructions in the technical operating 

manual are followed and applied to the intended range of operations. The system may only be operated 

by responsible personnel aware of the dangers and risks of operating the system. Malfunctions, in particu-

lar those, which affect the occupational safety must be eliminated immediately.

General

Summary of Contents for RL 250

Page 1: ...User Manual Dust Extractor RL 250 300 Keep this manual handy and in good condition for continual reference Dok ID 002 0 450_02 Englisch 2012 02 13 Translation...

Page 2: ...ify your supplier immediately For the safety of all personnel it is necessary to conscientiously study this manual before assembly and operation This manual must be kept in good condition as it belong...

Page 3: ...r 10 2 5 What is required of personnel 10 2 6 Work safety 10 2 7 Personal safety equipment 11 2 8 Other risks 11 2 9 Machine hazards 11 2 10 Fire hazards 12 2 11 Noise emission 12 2 12 Safety cover 13...

Page 4: ...s 23 18 3 Dust hazard prevention 24 18 4 Fire and explosion hazards prevention 24 19 Error recognition 25 20 Spare parts list RL 250 26 21 Spare parts list RL 300 27 22 Pulse jet cleaning pneumatic di...

Page 5: ...health injuries per manent impairment or death 1 General 1 1 Explanations of the symbols Important technical safety instructions in this manual are marked with symbols These instructions for work saf...

Page 6: ...ave any questions or are unclear about the instructions please do not hesitate to contact us Please have the machine serial number at hand when you contact us This operating manual is designed for eng...

Page 7: ...It is desig nated solely for those persons who work on or with the machine All descriptions texts drawings photos and other depictions are protected by copyright and other commercial laws Illegal use...

Page 8: ...h dust the exhaust air volume returned to the room by the dust extractor must not exceed 50 of the air delivered For natural ventilation assume an intake volume of 1x the room volume m3 h air exchange...

Page 9: ...ed All claims regarding damage resulting from improper use that are made against the manufacturer and its authorised representatives shall be rejected The operator shall be solely liable for any damag...

Page 10: ...he necessary knowledge for work ing on or with the machine they must first be trained Responsibility for working with the machine installation service maintenance overhaul must be clearly defined and...

Page 11: ...vertheless there are some remaining risks that must be considered The machine runs with high electrical voltage Warning Danger electric current Electrical energy can cause serious bodily injury Damage...

Page 12: ...kplace values Even though a relationship exists between particle emission and noise emission levels an inference cannot be made about whether additional safety measures need to be imple mented Factors...

Page 13: ...ode 2 Forwards the vacuumings towards the dust collecting sacks Ensure that this cover is always easy to move Safety cover Fig 1 Safety cover 2 13 Procedure in case of fire 1 Pull out the mains plug 2...

Page 14: ...delines 2006 42 EG We hereby declare that the machine indicated below which corresponds to the design and construction of the model we placed on the market conforms with the safety and health requirem...

Page 15: ...the device on a level floor surface Only set up and operate the duct extractor on an even surface Insert a chip sack The container is then hermetically connected to the dust extractor with a sealing c...

Page 16: ...st extractor is thus appropriate to extract and to separate dry wood moisture 30 wood dust and shavings whereby the residual dust contents level of 3 H3 0 1 mg m3 will be adhered to The dust inspectio...

Page 17: ...MRL Ambient temperature 5 40 C Compressed air consumption 12 l per filter cartridge and pulse Regular interval 90 sec 40 Pulse h 2400 Litre h Dimensions RL 300 Length 3015 mm Width 970 mm Height 2280...

Page 18: ...he equip ment cabinet switches itself on The filter component cleaning process starts simultaneously Once the device is switched off a manual cleaning process should start switch in the control cabine...

Page 19: ...ccess to the machine The filtered air from the dust extractor may only be recycled into the room it was extracted from The machine is only designed to extract dust from woodworking machines which do n...

Page 20: ...orresponds with the mains before connecting the device to the mains supply available This device may only be operated if the mains has an earthed neutral conductor Attention Note the direction of rota...

Page 21: ...the bypass line The spherical valve is sealed upon delivery so it is not activated unintentionally Min extinguishing water supply 12 litres Min Min extinguishing excess water pressure 1 2 Bar The fire...

Page 22: ...L switch off the device By pressing the cleaning key a jet of compressed air is triggered which removes dust and woodshavings from the filter This is to ensure that dust and woodshavings will not fall...

Page 23: ...the collecting containers during the cleaning process to collect the falling dust Control the individual cartridges for damage 18 Hazard prevention Remaining risks 18 1 Mechanical hazard prevention me...

Page 24: ...s mixture can develop into a very serious fire To fight this fire hazard the dust extractor has been equipped with an automatic spark extinguisher A temperature sensor detects the fire and the sensor...

Page 25: ...t and woodshav ings use a dust respirator 2 Containers are overflowing switch the machine off empty the containers insert the containers again and clean the cartridges if necessary use a dust mask swi...

Page 26: ...1029 3 Solenoid valve VEP 508 1 07 01 5602506 3 Solenoid for solenoid valve no illustration 08 5602913 1 Filter pressure regulator NL G3 4 09 5603012 1 Pressure gauge 10 560212212 1 Air operated solen...

Page 27: ...6 3 Valves VEP508 230 50 07 56021029 3 Solenoid valve VEP 508 1 07 01 5602506 3 Solenoid for solenoid valve no illustration 08 5602913 1 Filter pressure regulator NL G3 4 09 5603012 1 Pressure gauge...

Page 28: ...al valve inch 005 5775020 1 inch brass one way valve 006 5775018 1 Hose connection nipple inch 19 mm No 461 007 577809703 Pipe inch Spherical valve Bleed screw Fig 6 Compressed air supply connection R...

Page 29: ...to a stop Each valve cleans once with the preset interval see factory settings paragraph Auto mode switch in the centre Automatic operation The mobile dust extractor is started via the Ventila ting f...

Page 30: ...switch main switch Terminal strip for machine input potential free Solenoid valve controls Cleaning with extinguisher valve output ZELIO logic module HE 5711 This module is for activating jet cleaning...

Page 31: ...of valves 3 sealed Number of available valves must not be changed Extinguishing time 7 sealed Factor 7 extinguishing time must not be changed Impulse time 0 3 seconds Impulse time Valves Pause 210 sec...

Page 32: ...l 21 Fire extinguisher 21 G General 5 Guarantee Liability 7 H Hazard prevention 23 24 I Indicator lamps 29 Information about the manual 6 Intended use 8 M Maintenance 26 Modifications to the machine 9...

Page 33: ...33 Dust Extractor RL 250 RL 300...

Page 34: ...34 Dust Extractor RL 250 RL 300...

Page 35: ...35 Absaugger t RL 250 RL 300 Dust Extractor RL 250 RL 300...

Page 36: ...FELDER KG KR FELDER STR 1 A 6060 Hall in Tirol Tel 43 0 5223 58 50 0 Fax 43 0 5223 56 13 0 Email info felder at Internet www felder at...

Reviews: