Operating and installation instructions
FELA SWITCH CASAMBI | stationary 230 Volt wall switch / mobile battery switch
Status April 2020
FELA GmbH | Sturmbühlstraße 180 – 184 | 78054 Villingen-Schwenningen | HRB 600 728 Freiburg
Page 7 of 13
2.2.
Installation and electrical connection
The power unit must not be mounted or dismounted under voltage. Disconnect and check the
connecting cables before starting work.
When selecting the installation location and drilling, pay attention to the run of electrical lines or
existing supply lines.
DANGER!
Electric shock when touching live parts.
Electric shock can lead to death.
Before working on the unit, disconnect it and cover live parts in the environment.
Fig.: Circuit diagram and connections
Make sure there is sufficient space for the connecting cables when installing the power section. Avoid the
formation of trapped heat. The power section must be connected as shown above (L/N).
For this purpose, the connecting cables must be skinned approx. 6 - 8 mm. Then adjust the power unit and
fix it using the mounting screws of the flush-mounted insert. Finally, the front cover must be pushed onto
the power unit and clicked into place with an audible snap.