Changing the tool.
Before mounting or replacing cutting tool or accessories, pull the power plug.
This preventive safety measure rules out the danger of injuries through acciden-
tal starting of the power tool.
Mounting a grinding disc (figure 8).
Hold the drive shaft in place using the open-
jawed wrench SW 17.
MSfov852-1, MSfov852-1-180:
Hold the spin-
dle in place using the Allen key.
Loosen the clamping flange with the pin-type
face wrench.
Unscrew the clamping flange.
Replace the used-up grinding accessory
or insert a new one.
Pay attention that the grinding accessory
is properly centered between the sup-
port flange and the clamping flange.
Hold the drive shaft in place using the open-
jawed wrench SW 17. Manually screw on the
clamping flange again.
MSfov852-1, MSfov852-1-180:
Hold the spin-
dle in place using the Allen key. Manually
screw on the clamping flange again.
Tighten the clamping flange with the pin-type
face wrench.
Mounting a polishing tool.
Mount an elastic sanding plate to the power
tool as described under “Schleifscheibe mon-
tieren”.
Fasten the polishing tool to the sanding plate.
WARNING
Clamping flange
Face spanner
Fig. 8