18
en
Adjustments.
Before mounting or replacing application tools or accessories, remove the bat-
tery.
This preventive safety measure rules out the danger of injuries through
accidental starting of the power tool.
Setting the torque (figure 8).
Before putting the power tool into operation
for the first time, the torque must be set to
the exact value and checked. The power tool
is not preset by the the manufacturer.
Open the cover using a screwdriver.
Turn the tool holder until the hole can be
seen under the cover.
Adjust the desired torque with the torque
setting tool.
Turn in the direction of the “+” to increase
the torque.
Turn in the direction of the “–” to reduce the
torque.
Shut the cover again.
WARNING
Fig. 8
1.
2.
3.
4.
3 21 23 002 00 6
5.