Removing the armature (applies to: AGSZ 18-90 LBL)
1.
Remove the seal (1).
2.
Press the armature with the sealing ring (2) out of the intermediate gearbox.
Tools:
- Arbor press
- Sleeve
80 mm inner diameter
90 mm outer diameter