Fault
Remedy
Suction turbine does not run
Turn the device on
Check the power cable, plug, fuse, outlet and fill level sensors
Operating mode selector switch is set to "Start/Stop Automatic".
Set the operating mode selector switch to the "Extract" symbol
and switch on the power tool connected to the socket
Check/replace device switch. Check socket
Check/replace PCB
Container is full in wet operation. Empty container
Empty container
Suction turbine switches off
Switch off extractor and wait 5 seconds before switching on again
Suction turbine does not start again after emptying container.
Clean the fill level sensors and space between the fill level
sensors with a brush