FEIN - Repair - Tools
Alle Rechte bei FEIN, insbesondere für den Fall der Schutzrechtanmeldung.
Jede Verfügungsbefugnis wie Kopieren und Weitergabe liegt bei FEIN.
MVK
04 / 08
3.2. Major function control 1
Malfunction
Possible Causes
Test Possibilities
3.2.1
Motor does not start
Switching sequence not maintained.
Broken mains cable
or plug connections.
Motor switch defective.
Dust deposits in the area of the motor
switch (self-start lock is activated)
Carbon brushes are worn out.
Motor defective.
Electronics defective.
Switch motor switch off
and on again.
Test continuity
Check.
Clean area.
Visual inspection, measurement
Check motor without electronics.
-
Loosen motor connections from
electronics.
-
Operate motor using transformer
with max. 75% mains voltage.
Check electronics without motor.
-
Loosen motor connections from
electronics
-
Connect approx.100 W substitute
load (e.g. light bulb) to electronics
(see test switch for electronics removed).
With 100 W light bulb, on-load voltage
must amount to110 V-130 V.