background image

 

 

 

ATTENTION 
 
IMPORTANT SAFETY 
INFORMATION 
 
For reasons of personal 
safety, it is important to 
follow these instructions.  
 
Store these instructions. 

TST 

LGB 

 

Length Variants 

-A / -B / -C / -D / -E 

 

 

DE 

ACHTUNG! WICHTIGE SICHERHEITSANWEISUNGEN! 
Den Hinweisen auf Seite 2 dieses Handbuchs ist Folge zu leisten. 
 

EN 

ATTENTION! IMPORTANT SAFETY INFORMATION! 
Follow the instructions on page 2 of this manual. 
 

FR 

ATTENTION! IMPORTANTES INDICATIONS DE SÉCURITÉ! 
Les instructions de la page 2 de cette notice de montage doivent 
être observées strictement. 
 

ES 

ATENCION INDICACIONES IMPORTANTES DE SEGURIDAD! 
Deben seguirse las indicaciones detalladas en página 2 de estas 
instrucciones de montaje. 
 

IT 

ATTENZIONE! INDICAZIONI SULLA SICUREZZA IMPORTANTI! 
Prestare attenzione alle note alla pagina 2 delle presenti istruzioni 
di montaggio. 
 

NL 

LET OP! BELANGRIJKE VEILIGHEIDSINSTRUCTIES! 
Volg de instructies op pagina 2 van deze handleiding op. 
 

DA 

PAS PÅ! VIGTIGE SIKKERHEDSANVISNINGER 
Oplysningerne på side 

 2 

denne 

monteringsvejledning

 skal følges. 

 

 
 

Assembly instructions 

Installation, commissioning, utilization and maintenance 

 
 

Summary of Contents for TST LGB

Page 1: ...ions de la page 2 de cette notice de montage doivent tre observ es strictement ES ATENCION INDICACIONES IMPORTANTES DE SEGURIDAD Deben seguirse las indicaciones detalladas en p gina 2 de estas instruc...

Page 2: ...dans la zone t l chargements de www feig de Pri re de vous logger avec les donn es suivantes Nom d utilisateur Download Mot de passe feig NL LET OP BELANGRIJKE VEILIGHEIDSINSTRUCTIES Voor de veilighei...

Page 3: ...TST Assembly instructions LGB FEIG ELECTRONIC GmbH Page 3 of 26 TST_LGB_Assembly_instructions_rev5_EN docx 1 2 3 Download feig...

Page 4: ...uction shows only a small part of the applicable functions does not contain any warranty of any characteristics Advanced functions and descriptions of individual door functions are available from the...

Page 5: ...id for these TST LGB in the length variants A B C D E The following characters are used in the functional description to point out the different danger zones and useful hints ATTENTION Indicates that...

Page 6: ...llation 11 4 3 Mounting the light curtain 11 5 Electrical connection 14 5 1 Wire assignment of the light curtain 14 5 2 Wiring diagrams for the wiring board RLGxA 15 5 3 Connecting the RLGxA wiring bo...

Page 7: ...n accordance with the intended use the TST LGB monitors the range below the door s edge of motor operated industrial or commercial doors and thus protects persons and objects against the door starting...

Page 8: ...applications that may not necessarily match the actual applica tion The actual application is provided by the manufacturer of the door as part of the overall documentation or as part of the operating...

Page 9: ...TST_LGB_Assembly_instructions_rev5_EN docx 3 Length variants Type Type Type Type Type to to to to to at at at at at Figure 3 Length variants ATTENTION The TST LGB variants must be selected in such a...

Page 10: ...ng the light curtain Table 1 Available mounting accessories Mounting kit TST KASK LGB A A consisting of the following articles Light curtain bracket set 8 pieces LGxASK Wiring board TST RLGxA A Connec...

Page 11: ...be avoided that ambient light incident on the receiver Such as an opposite mounted transmitter of an additional light curtain The door s closing edge at the transition between two neighbouring light...

Page 12: ...TST Assembly instructions LGB FEIG ELECTRONIC GmbH Page 12 of 26 TST_LGB_Assembly_instructions_rev5_EN docx Figure 5 Bracket positions for light curtains...

Page 13: ...n be mounted directly along the door rail Figure 6 Door frame top view Table 3 Door frame top view Position Designation 1 Door frame 2 Light curtain with bracket 3 Door rail 4 Door panel 3 Mount the b...

Page 14: ...uctors 8 Conductor cross section 0 25 mm Transmitter Plug connector M12 4 pole coupling Number of conductors 4 Conductor cross section 0 25 mm 5 1 Wire assignment of the light curtain Pin 1 brown Pin...

Page 15: ...TST Assembly instructions LGB FEIG ELECTRONIC GmbH Page 15 of 26 TST_LGB_Assembly_instructions_rev5_EN docx 5 2 Wiring diagrams for the wiring board RLGxA Figure 9 Wiring diagram for the light curtain...

Page 16: ...TST Assembly instructions LGB FEIG ELECTRONIC GmbH Page 16 of 26 TST_LGB_Assembly_instructions_rev5_EN docx Figure 10 Wiring diagram for position encoders...

Page 17: ...ction for the position encoder The RLGxA wiring board is suitable for the following products Table 5 Use of the RLGxA wiring board Product Designation Door controller TST WU TST FUZ2 TST FUxF Light cu...

Page 18: ...strip for position encoder b Terminal block for position encoder c Wiring board RLGxA Connecting the wiring board 1 Remove the terminal block for the position encoder b from the controller board see...

Page 19: ...re continuing Potential errors incorrect wiring or objects within the range that may be secured For the duration of the set up procedure the monitored area must be free from objects To mask out the up...

Page 20: ...ood signal quality Flashing 10 Hz One light beam is occupied but otherwise bad signal quality on Several light beams occupied In the case of improvement of the Light beam alignment between the TST LGB...

Page 21: ...response time of less than 10 ms to detect occupancy An assignment in the danger zone activates OUT 1 With the appropriate parameter configuration OUT1 results in a hard stop of the door movement The...

Page 22: ...but no later than after 8 hours OUT1 Table 8 Tristate mode OUT1 Output condition open Internal error 0 Occupation of the danger zone 8 2 k Danger zone vacant Table 9 24 V digital mode OUT1 Output con...

Page 23: ...one OUT2 Object zone Figure 16 Different zones By dividing the monitored zone in danger and object zone the door controller can respond accordingly to the detection of the different events An assignme...

Page 24: ...ing not successful flashing 5 Hz RS485 communication problem to TST LGB Receiver Table 12 TST LGB receiver LED blue Status off TST LGBS disconnected from the power On Voltage applied unit faulty flash...

Page 25: ...nsumption A Variant 24 V DC 10 Transmitter 50 mA Receiver 30 mA Reverse polarity protection Yes Short circuit protection Yes Optical System Wavelength 850 nm Aperture angle EAA 5 Ambient light immunit...

Page 26: ...TST Assembly instructions LGB FEIG ELECTRONIC GmbH Page 26 of 26 TST_LGB_Assembly_instructions_rev5_EN docx 12 Declaration of conformity...