Installation Manual ID RW01...-A / -B
FEIG ELECTRONIC GmbH
Page 15 of 20
E N G L I S H
2. Reader Connection: X1
Pin
Description
Function
1
GND
2
VCC
5V DC (use regular voltages only)
3
OUT1
(/CLS)
output:
•
RS232 interface: data carrier within reading range
data/clock interface: valid data
(from PCB version FE 423-1)
4
RxD
asynchronous interface
•
ID RW01-A: RS232
•
ID RW01-B: RS232-TTL
5
/DTT
data/clock interface: clock output
6
/DTD
data/clock interface: data output
7
IN1
input: power saving mode
8
TXD
asynchronous interface
•
ID RW01-A: RS232
•
ID RW01-B: RS232-TTL
9
ANT1
external antenna
10
ANT2
external antenna
2.1 Connecting the data/clock interface:
The 3 outputs of the data/clock interface at X1 Pin 3 (OUT1, /CLS), Pin 5 (/DTT) and Pin 6 (/DTD)
are compatible to TTL. They are equipped with an internal 10 k
Ω
pull-up resistor.
2.2 IN1 (Power Saving Mode):
With X1 Pin 7 (IN1) and according configuration (see: "System Manual - ID RW Series, Standard
Readers" the power saving mode of the reader can be activated. To activate the power saving
mode input IN1 must be connected to GND (X1 Pin 1) of the reader.
The connection of extraneous voltage might damage the reader.