4.5.2 Relay
A changeover relay is provided on terminal X6.
Table 4-10: Relay output pinouts
Terminal
Abbreviation
Description
X6 / Pin 1
COM
Working contact
X6 / Pin 2
NC
Normally closed
X6 / Pin 3
NO
Normally open
Fig. 4-9: Internal and possible external wiring of the relay output
Notes:
•
The relay outputs are configured for max. 24 VDC
/ 2 A.
•
The relay outputs are intended for switching resistive loads only. If an inductive load is
used, the relay contacts must be protected by means of an external protection circuit.
X6
N0
NC
COM
Uext