background image

 

MONTAGE  

INSTALLATION 

 

final 

public (B) 

2012-03-08 

M70201-4de-ID-B.doc 

 

   

ID ISC.MRU200 

MidRange Reader UHF 

 

 

 

 

(deutsch / english) 

 

Summary of Contents for OBID i-scan UHF ISC.MRU200

Page 1: ...MONTAGE INSTALLATION final public B 2012 03 08 M70201 4de ID B doc ID ISC MRU200 MidRange Reader UHF deutsch english...

Page 2: ...OBID i scan Montage ID ISC MRU200 FEIG ELECTRONIC GmbH Seite 2 von 52 M70201 4de ID B doc D E U T S C H deutsche Version ab Seite 3 english version from page 28 E N G L I S H...

Page 3: ...Wissen und Gewissen FEIG ELECTRONIC GmbH bernimmt keine Gew hrleistung f r die Richtigkeit und Vollst ndigkeit der An gaben in diesem Dokument Insbesondere kann FEIG ELECTRONIC GmbH nicht f r Folgesch...

Page 4: ...9 3 2 Dichtverschl sse 9 3 3 Deckelhalter 10 3 4 Designblenden 10 4 Anschlussklemmen und buchsen 11 4 1 Versorgungsspannung 12 4 2 Antennenanschl sse 13 4 3 Schnittstellen 14 4 3 1 RS232 Schnittstelle...

Page 5: ...G ELECTRONIC GmbH Seite 5 von 52 M70201 4de ID B doc D E U T S C H 5 3 J1 J8 Schnittstellenkonfiguration 22 5 4 X62 Bootloader Modus 23 6 Technische Daten 24 6 1 Zulassung 26 6 1 1 Europa CE 26 6 1 2...

Page 6: ...ne ungeeignete falsche manuelle oder automatische Einstellung von Parametern f r ein Ger t bzw ungeeignete Verwendung eines Ger tes wird keine Haftung bernommen Reparaturen d rfen nur vom Hersteller d...

Page 7: ...Readertypen Readertyp Beschreibung ID ISC MRU200 USB EU Reader mit USB Schnittstelle f r Europa ID ISC MRU200 E EU Reader mit Ethernet Schnittstelle f r Europa ID ISC MRU200 USB FCC Reader mit USB Sc...

Page 8: ...Art der Schrauben und Befestigungsd bel h ngt stark von der Festigkeit des Untergrundes ab Die D bel und Schrauben sollten mindestens eine zul ssige Last von 1 5 kN f r alle Belastungsrichtungen aush...

Page 9: ...nge 4 M 12 3 5 7 Schnittstelle seriell 5 M 12 3 5 7 Spannungsversorgung 6 M 25 9 17 Ethernet Interface nur E USB nur A 3 2 Dichtverschl sse Mit denen im Zubeh r beigelegten Dichtverschl ssen k nnen n...

Page 10: ...an dem Geh use fixiert werden Die Deckelhalter werden in die daf r vorgesehenen ffnungen eingesteckt Bild 3 3 Deckelhalter 3 4 Designblenden Die Designblenden werden nach der Montage des Readers aufg...

Page 11: ...nd buchsen In Bild 4 1 und Bild 4 2 sind alle Anschlussklemmen und buchsen sowie die Bedien und Anzei geelemente f r die Readertypen USB bzw E dargestellt Bild 4 1 Anschlussklemmen und buchsen Typ A T...

Page 12: ...zeichen Beschreibung X1 Pin 1 VDC VDC Versorgungsspannung X1 Pin 2 GND Ground Versorgungsspannung Bild 4 3 Anschluss der Versorgungsspannung Die Ausgangsleistung des Netzteils sollte min 15 W betragen...

Page 13: ...tennen erfolgt ber die SMA Buchsen ANT1 und ANT2 Das SWR der ange schlossen Antennen mit Kabel darf 1 5 1 nicht berschreiten Tabelle 4 2 Antennenanschluss Anschluss Beschreibung ANT1 ANT2 SMA Buchse f...

Page 14: ...X2 Die bertragungsparameter k nnen per Softwareprotokoll konfiguriert werden Tabelle 4 3 Pinbelegung RS232 Schnittstelle Klemme Kurzzeichen Beschreibung X2 Pin 1 GND RS232 GND X2 Pin 2 RxD RS232 RxD...

Page 15: ...5 3 J1 J8 Schnittstellenkonfiguration Der Anschluss der RS485 bzw RS422 Schnittstelle erfolgt ber X3 Tabelle 4 4 zeigt die Pinnbelegung f r die entsprechende Schnittstelle Tabelle 4 4 Pinbelegung RS48...

Page 16: ...TX Transmit Data X7 Pin 2 TX Transmit Data X7 Pin 3 RX Receive Data X7 Pin 4 VETH n c X7 Pin 5 VETH n c X7 Pin 6 RX Receive Data X7 Pin 7 VETH n c X7 Pin 8 VETH n c Vorraussetzung f r den Einsatz des...

Page 17: ...e X5 sind galvanisch von der Reader Elektronik getrennt und m ssen daher mit einer externen Gleichspannung versorgt werden Die Eingangs LEDs der Optokoppler sind intern mit einem Serienwiderstand Rint...

Page 18: ...1 24 V 820 Hinweise Die Eing nge sind f r eine maximale Eingangsspannung von 24 VDC und einen Ein gangsstrom von maximal 20 mA ausgelegt Verpolung oder berlastung der Eing nge f hrt zu deren Zerst run...

Page 19: ...m ssen daher mit einer externen Spannung betrieben werden Tabelle 4 9 Pinbelegung Optokopplerausg nge Klemme Kurzzeichen Beschreibung X4 Pin 1 O1 C Kollektor Ausgang 1 X4 Pin 2 O1 E Emitter Ausgang 1...

Page 20: ...emme Kurzzeichen Beschreibung X6 Pin 1 COM Arbeitskontakt X6 Pin 2 NC ffner X6 Pin 3 NO Schlie er Bild 4 9 Interne und m gliche externe Beschaltung des Relaisausgangs Hinweise Der Relaisausgang ist f...

Page 21: ...ein kurzes Blinken die fehlerfreie Kommunikation mit einem Transponder auf der RF Schnittstelle Blinkt abwechselnd mit V1 nach dem Reset im Anschluss an ein Software Update Blinkt abwechselnd mit V1...

Page 22: ...zugeschaltet werden Tabelle 5 3 Abschlusswiderst nde der RS485 RS422 Jumper Geschlossen offen J1 Pull Up an RS4xx B ohne Pull Up an RS4xx B J2 Pull Down an RS4xx A ohne Pull Down an RS4xx A J5 Abschlu...

Page 23: ...der Modus Die Stiftleiste X62 kann mit einem Jumper Rasterma 2 0 mm kurzgeschlossen werden In Ta belle 5 4 ist die Funktion der Stiftleiste X62 beschrieben Tabelle 5 4 Stiftleiste X62 X60 Beschreibung...

Page 24: ...gsversorgung 12 24 VDC 5 Noise Ripple max 150 mV Leistungsaufnahme max 15 VA Betriebsfrequenz 865 6 867 6 MHz EN 302 208 902 928 MHz FCC CFR 47 Part 15 247 Sendeleistung 100 300 mW 100 mW Step Softwar...

Page 25: ...ose des Betriebszustandes Multi Reader Betrieb Synchronisation der Luftprotokolle durch Ver wendung der Reader Synchronisation Umgebungsbedingungen Temperaturbereich Betrieb Lagerung 25 55 C 25 85 C V...

Page 26: ...at may cause undesired operation NOTICE Changes or modifications made to this equipment not expressly approved by FEIG ELECTRONIC GmbH may void the FCC authorization to operate this equipment This equ...

Page 27: ...radiated power EIRP is not more than that permitted for successful communication This device has been designed to operate with the antennas listed below and having a maximum gain of 10 5 dBic Antennas...

Page 28: ...on in this manual has been done to the best of our knowledge FEIG ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this manual and may not be held liable for...

Page 29: ...stallation 33 3 1 Cable Glands 34 3 2 Seal Caps 34 3 3 Cover stays 35 3 4 Decorative Covers 35 4 Terminals and Jacks 36 4 1 Supply Voltage 37 4 2 Antenna Connections 38 4 3 Interfaces 39 4 3 1 RS232 I...

Page 30: ...00 FEIG ELECTRONIC GmbH Page 30 of 52 M70201 4de ID B doc E N G L I S H 5 3 J1 J8 Interface configuration 47 5 4 X62 Boot Loader Mode 48 6 Technical Data 49 6 1 Approval 51 6 1 1 Europe CE 51 6 1 2 US...

Page 31: ...or the device The manufacturer shall not be held legally responsible for inaccuracies errors or omissions in the manual or automatically set parameters for a device or for an incorrect application of...

Page 32: ...urrently available Table 2 1 Available Reader types Reader type Description ID ISC MRU200 USB EU Reader with USB Interface for Europe ID ISC MRU200 E EU Reader with Ethernet Interface for Europe ID IS...

Page 33: ...The size and type of the screw anchors depends considerably on the strength of the wall The anchors should be capable of withstanding a permissible load of at least 1 5 kN per anchor for all load dir...

Page 34: ...0 0 18 0 39 Inputs Relay Outputs 4 M 12 3 5 7 0 14 0 28 Interface serial 5 M 12 3 5 7 0 14 0 28 Supply voltage 6 M 25 9 17 0 35 0 67 Ethernet Interface Model E only USB Interface Model USB only 3 2 Se...

Page 35: ...ed to attach the cover to the housing The cover stays are inserted into the openings provided for this purpose Fig 3 3 Cover stay 3 4 Decorative Covers The decorative covers are attached after install...

Page 36: ...minals and Jacks Fig 4 1 and Fig 4 2 show terminals jacks and operating elements of reader type USB respective ly reader type E Fig 4 1 Terminals jacks and operating elements of Type USB T1 K1 X6 X5 X...

Page 37: ...y voltage pin assignments Terminal Abbreviation Description X1 Pin 1 VDC Vcc supply voltage X1 Pin 2 GND Ground supply voltage Fig 4 3 Connecting the supply voltage The output power of the power suppl...

Page 38: ...the SMA jacks ANT1 and ANT2 The SWR of the con nected antennas with the cables should not be worse than 1 5 1 Table 4 2 Antenna Connections ANT1 and ANT2 Connections Description ANT1 ANT2 SMA jacks f...

Page 39: ...n X2 The transmission parameters can be configured by means of software protocol Table 4 3 RS232 interface pinouts Terminal Abbreviation Description X2 Pin 1 GND RS232 GND X2 Pin 2 RxD RS232 RxD X2 Pi...

Page 40: ...n be configured for RS485 or RS422 see 5 3 J1 J8 Inter face configuration The RS485 interface respectively RS422 interface is connected to X3 Table 4 4 RS485 RS422 interface pinouts Terminal Abbreviat...

Page 41: ...Data X7 Pin 2 TX Transmit Data X7 Pin 3 RX Receive Data X7 Pin 4 VETH n c X7 Pin 5 VETH n c X7 Pin 6 RX Receive Data X7 Pin 7 VETH n c X7 Pin 8 VETH n c The prerequisite for using TCP IP protocol is...

Page 42: ...puts in Terminal X5 are galvanically isolated from the Reader electronics and must therefore be externally supplied The input LEDs for the optocouplers are switch internally with a series resistor Rin...

Page 43: ...series resistor Rext 5 10 V 11 15 V 270 16 20 V 560 21 24 V 820 Notes The inputs are configured for a maximum input current of 24 VDC and an input current of maximum 20 mA Reversing the polarity or ov...

Page 44: ...must therefore be powered with an external power supply Table 4 9 Optocoupler output pin configuration Terminal Abbreviation Description X4 Pin 1 O1 C Collector Output 1 X4 Pin 2 O1 E Emitter Output...

Page 45: ...ion Description X6 Pin 1 COM Working contact X6 Pin 2 NC Normally closed X6 Pin 3 NO Normally open Fig 4 9 Internal and possible external wiring of the relay output Notes The relay outputs are configu...

Page 46: ...flashing indicates errorless communication with a transponder on the RF interface Flashes alternately with V1 after a reset following a software update Flashes alternately with V1 in case of a data er...

Page 47: ...Termination resistors for RS485 RS422 Jumper closed open J1 Pull Up on RS4xx B without Pull Up on RS4xx B J2 Pull Down on RS4xx A without Pull Down on RS4xx A J5 Termination resistor RS4xx A RS4xx B w...

Page 48: ...age 48 of 52 M70201 4de ID B doc E N G L I S H 5 4 X62 Boot Loader Mode The pin connector X62 can be closed with a jumper 2 0 mm Table 5 4 pin connector X62 X62 Description open no effect closed after...

Page 49: ...age 12 24 VDC 5 Noise Ripple max 150 mV Power Consumption max 15 VA Operating Frequency 869 525 MHz EN 300 220 865 6 867 6 MHz EN 302 208 902 928 MHz FCC CFR 47 Part 15 247 Transmitting Power 100 300...

Page 50: ...perating status diagnostics Multi Reader Operation Synchronization of the air protocols using Reader synchronization Ambient Temperature range Operating Storage 25 55 C 13 131 F 25 85 C 13 185 F Vibra...

Page 51: ...y cause undesired operation NOTICE Changes or modifications made to this equipment not expressly approved by FEIG ELECTRONIC GmbH may void the FCC authorization to operate this equipment This equipmen...

Page 52: ...y radiated power EIRP is not more than that permitted for successful communication This device has been designed to operate with the antennas listed below and having a maximum gain of 10 5 dBic Antenn...

Reviews: