background image

OBID

 

i-scan

 ® 

UHF 

Installation 

ID ISC.PRHD102 

 

FEIG ELECTRONIC GmbH 

Page 11 of 23 

M80601-4e-ID-B.docx 

 

4. Assembly and Wiring 

4.1. Reader with Bluetooth™ interface ID ISC.PRHD102-B 

The Reader has a Bluetooth port. The supply voltage is provided only by rechargeable batteries. 

The Reader is activated using the Scan button. This opens a Bluetooth connection automatically 
within approx. 3 seconds. The Reader is now ready to use. After releasing the button, the Reader 
remains active for several minutes. During this time the Bluetooth connection remains open. 
Pressing the button again immediately starts a Scan. 

 

4.1.1. Bluetooth™(BT) interface 

Communication to the Reader is through a Bluetooth connection. Bluetooth is a short-distance 
wireless RF connection which enables permanent wireless communications connections between 
portable and desktop or peripheral devices. Each Bluetooth device has a unique address and can 
be optionally identified with a self-explanatory name. Password protection is used for security of a 
Bluetooth connection, with the Bluetooth partner being added to a confidential list. SPP (Serial Port 
Profile) is used. 

Initial setup of a “paired connection“ to the Reader is done by the host. After initial setup the 
establishment of the bluetooth connection happens automatically by pressing the Scan button. To 
establish a connection to another Bluetooth-Dongle you must first clear the existing “paired 
connection” entry in the bluetooth interface of the reader (see 

4.1.4. Reset -  button (ID 

ISC.PRHD102-B only)

). 

All Readers have a factory set name and a preset password. The name "OBID_PRHD102B" 
consists of a fixed (OBID_PRHD) and a user modifiable (102B) part. 

Table 3: configuration of the Bluetooth Interface 

Description 

Default setting 

Name variable 

102B 

Password 

1234 

 

NOTE: 
Until FECOM.DLL version 2.8.8 the COM-Port setting “Char Timeout Multiplier” from PC or 
Notebook  should be increased to 9-10 if a Bluetooth reader is used. 

 

Summary of Contents for OBID i-scan ISC.PRHD102

Page 1: ...INSTALLATION final public B 2013 02 01 M80601 4e ID B docx ID ISC PRHD102 HF UHF combined Handheld Reader ...

Page 2: ...f this document FEIG ELECTRONIC call explicit attention that devices which are subject of this document are not designed with components and testing methods for a level of reliability suitable for use in or in connection with surgical implants or as critical components in any life support systems whose failure to perform can reasonably be expected to cause significant injury to a human To avoid da...

Page 3: ...mer issue If bits within one byte are filled with these bit spaces are reserved for future extensions or for internal testing and manufacturing functions These bit spaces must not be changed as this may cause faulty operation of the reader The following figure formats are used 0 9 for decimal figures 0x00 0xFF for hexadecimal figures b0 1 for binary figures The hexadecimal value in brackets marks ...

Page 4: ...interface ID ISC PRHD102 B 11 4 1 1 Bluetooth BT interface 11 4 1 2 Supply voltage 12 4 1 3 Charging the batteries 13 4 1 4 Reset button ID ISC PRHD102 B only 14 4 1 5 Switching over HID Mode and Standard Mode ID ISC PRHD102 B only 15 4 2 Reader with USB interface ID ISC PRHD102 USB 16 5 Technical Data 17 6 Radio Approvals 19 6 1 Europe CE 19 6 2 Declaration of Conformity Directive 1999 5 EC R TTE...

Page 5: ...OBID i scan UHF Installation ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 5 of 23 M80601 4e ID B docx ANNEX 23 ANNEX A Accessories 23 ANNEX B Skope of Delivery 23 ...

Page 6: ... valid for the device The manufacturer shall not be held legally responsible for inaccuracies errors or omissions in the manual or automatically set parameters for a device or for an incorrect application of a device Repairs may only be executed by the manufacturer Installation operation and maintenance procedures should only be carried out by qualified personnel Use of the device and its installa...

Page 7: ...l antennas and will be delivered ready for connection The device is designed as a handheld An anti collision function enables simultaneous reading of several transponders per second The Reader electronic is fitted in a plastic housing with a protection class IP30 The Reader ID ISC PRHD102 B has an Bluetooth interface and the ID ISC PRHD102 USB has an USB interface Depending on if HF or UHF transpo...

Page 8: ...th interface with internal antennas and voltage supply by means of 4 rechargeable Mignon AA batteries ID ISC PRHD102 USB EU Reader for Europe Reader with USB interface with internal antennas Powered via a high powered USB port ID ISC PRHD102 B FCC Reader for USA Canada etc Bluetooth interface with internal antennas and voltage supply by means of 4 rechargeable Mignon AA batteries ID ISC PRHD102 US...

Page 9: ...lements 3 1 Signal buzzer The signal buzzer can be configured by the software In the standard configuration the signal buzzer will be active if a Transponder is recognized 3 2 Scan button The switch of the reader can be configured by the software In the standard configuration the serial number of the Transponder is read and is sent to the host after pressing the scan button ...

Page 10: ...blishment only ID ISC PRHD102 B LED blue TRANSPONDER Turns on when a Transponder is detected LED red WARNING Signals a warning Turns on if battery voltage is flat no more scanning possible only ID ISC PRHD102 B LED orange INITIALIZING and WARNING Flashes during Reader initialization after power up Turns on if battery voltage is too low rechargeable battery must be charged only ID ISC PRHD102 B LED...

Page 11: ... Bluetooth device has a unique address and can be optionally identified with a self explanatory name Password protection is used for security of a Bluetooth connection with the Bluetooth partner being added to a confidential list SPP Serial Port Profile is used Initial setup of a paired connection to the Reader is done by the host After initial setup the establishment of the bluetooth connection h...

Page 12: ... in the compartment according to the and symbols indicated note polarity Then replace the cover and listen for the spring to audibly latch Table 4 Designations for rechargeable Mignon type batteries General type Europe USA Size D l Mignon R6 UM 3 AA 15mm 51mm NOTE Use only Nickel Cadmium NiCd or Nickel Metal Hydride NiMH batteries Do not use single use batteries e g zinc carbon alkaline batteries ...

Page 13: ...ation Description Inside Plus charge voltage Outside Minus charge voltage NOTE Reversing the polarity of the charger can destroy the batteries The Reader is not functional while the batteries are charging Charger Use a charger suitable for the battery type specified 4 cell pack Table 6 Recommended charger Feig Article No Name 2650 000 00 ID CHA NiMH A The recommended charger is designed for nickel...

Page 14: ...to its factory settings by holding the Reset button and the Scan button down for longer than 4 seconds until the violet LED light up 2 Clear paired connection entry in internal bluetooth interface After activating the Reader with the Scan button the paired connection entry in Bluetooth interface is cleared by holding the Reset button down for longer than 4 seconds until the violet LED light up See...

Page 15: ...n the device This is shown in figure 7 After the device was powered up release the Reset button Now the reader will toggle the output mode to HID Mode If you want to switch back the Standard Mode you must switch off the read er by double click on the Scan button and repeat the above described procedure again The reader will remain in the output mode you ve configured last till you start the proced...

Page 16: ...current of 500mA High Powered Interface The data rate of the reader is reduced to 12 Mbit USB high speed The reader dispose of a fixed connected interfaces cable with standardized USB connector The Reader must only be connected to the USB port of the PC If the reader is used for the first time it must be registered in the operating system of the computer For this the instruction M30100 xde ID B In...

Page 17: ...C PRHD102 B ID ISC PRHD102 USB no cable 2 5 m 8 2 ft USB cable Color similar RAL 9002 ELECTRICAL DATA Power Supply ID ISC PRHD102 B ID ISC PRHD102 USB 4 Mignon AA rechargeable batteries USB High Powered Interface Power Consumption max 2 5 W Operating Frequency HF UHF 13 56 MHz EU 865 MHz to 868 MHz FCC 902 MHz to 928 MHz RF Power HF UHF max 200 mW 2 dB max 100 mW 2 dB Antenna Connection 2 x integr...

Page 18: ...LRI ISO Chips TI Tag it EPC Class 1 Generation 2 ISO 18000 6 C Upgrade Code required Signaler optical acoustical 1 x LED multi color red green blue 1 x Buzzer AMBIENT CONDITIONS Temperature Range Operation Storage 0 C to 50 C 32 F to 122 F 20 C to 70 C 4 F to 158 F Humidity 5 to 95 non condensing Fall withstands multiple 1 5 m 5 ft drops to con crete APPLICABLE STANDARDS Radio Regulation Europe US...

Page 19: ...601 4e ID B docx 6 Radio Approvals 6 1 Europe CE When properly used this radio equipment conforms to the essential requirements of Article 3 and the other relevant provisions of the R TTE Directive 1999 5 EC of March 99 Performance Classification according to ETSI EN 301 489 Class 2 ...

Page 20: ...OBID i scan UHF Installation ID ISC PRHD102 FEIG ELECTRONIC GmbH Page 20 of 23 M80601 4e ID B docx 6 2 Declaration of Conformity Directive 1999 5 EC R TTE Figure 8 Declaration of Conformity ...

Page 21: ... Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in ...

Page 22: ...ication number or model number if Category II has been approved by Industry Canada to operate with the antenna types listed below with maxi mum permission gain and required antenna impedance for each antenna type indicated Antenna types not included in this list having a gain greater than the maximum gain indicated for that type are strictly prohibited for use with this device Le présent émetteur ...

Page 23: ...Delivery Table 8 Scope of delivery Reader Scope of delivery ID ISC PRHD102 B Reader ID ISC PRHD102 B Quick user guide Configuration Software and Documenta tion download from FEIG Public Download Area ID ISC PRHD102 USB Reader ID ISC PRHD102 USB Quick user guide USB driver Configuration Software and Documentation download from FEIG Public Download Area NOTE Rechargeable batteries and battery charge...

Reviews: