3 Installation and Connection
3.1 RS232 asynchronous interface
The RS232 interface uses a 9-pin D-Sub female connector.
The transmission parameters can be configured using software protocol.
Pin assignments for the 9-pin D-Sub female connector (RS232 interface):
Pin
Designation
Description
2
TxD
RS232 – TxD
3
RxD
RS232 – RxD
5
GND
RS232 – GND
1; 4; 6-9
---
n.c.
Table 3-1: Pin configuration for the RS232 interface