OBID i-
scan
®
Installation
ID ISC.MRU200i
FEIG ELECTRONIC GmbH
Page 33 of 52
M80401-3de-ID-B.doc
E
N
G
L
I
S
H
3
Installation
The Reader is designed for wall mount. Four Holes are provided in the housing for wall attachment
(d=5mm (.19”), measurement 54x179mm). The housing does not need to be opened for installa-
tion on a wall (see Fig. 3-1). The size and type of the screw anchors depends considerably on the
strength of the wall. The anchors should be capable of withstanding a permissible load of at least
1.5 kN per anchor for all load directions (Undersurface steal e.g. cylinder head screw M3,5 or M4
steal zinc coated DIN 84 / ISO 1207, property class 8.8 or concrete, stone e.g. plastic anchor 5mm
with wood screw DIN96 d=3.5mm). The maximum size of the screw head is 7mm (0.29”)
Fig. 3-1: Housing ID ISC.MRU200i (all dimensions in mm (inch))
3.1 Cable Glands
The different cable glands are shown in Table 3-1.
Table 3-1: ID ISC.MRU200i cable glands
Cable gland
Size
Clamping Range
in mm (inch)
Description
1
M 16
4,5...10 (0.18...0.39)
Inputs / Relay / Outputs
2
M 12
3,5...7 (0.14...0.28)
Interface (serial)
3
M 12
3,5...7 (0.14...0.28)
Supply voltage
4
M 25
9...17 (0.35...0.67)
Ethernet Interface (Model
–E only)
USB Interface (Model
–USB only)
110 (
4.33)
200 (7.87)
1
2
3
4
54 (2
.13)
179 (7.05)
Summary of Contents for OBID i-scan ID ISC.MRU200i
Page 27: ......