OBID
®
classic-pro
Installation
ID CPR.M02
FEIG ELECTRONIC GmbH
Page 42 of 42
M21001-3de-ID-B.doc
E N G L I S H
10. Technical Data
•
Dimensions ( W x H x D )
50 mm x 50 mm x 14 mm
•
Connector
10 pol. Pin-Connector (grid dim. 2,54 mm)
•
Supply voltage
5 V DC
±
5%
ripple
0...250 kHz < 10 mVpp
ab 250 kHz < 0,1 mVpp
•
Power Consumption
max. 1,5 W
•
Operating Frequency
13.56 MHz
•
RF Transmitting Power
250 mW
±
2 dB
•
Antenna:
ID CPR.M02.VP/AB-B / -C
ID CPR.M02.VP/AB-BA / -CA
Internal, 48 mm x 48 mm
External (separate 2 pol. Pin-Connector)
•
RS232-TTL Interface:
ID CPR.M02.VP/AB-B / -BA
ID CPR.M02.VP/AB-C / -CA
4.800 to 38.400 Baud
4.800 to 230.400 Baud
•
Daten-/Takt Interface
•
Magnet Stripe Emulation
•
Wiegand
Emulation
•
EEPROM (for parameters)
1 kB
(10,000 write cycles)
•
FLASH
64 kB
(software update on interface possible)
•
Supported Transponders
read and write
•
ISO14443-A
compatible
(e. g. mifare, mifare Ultra Light, my-d proximity)
•
ISO14443-B
compatible
•
ISO15693
compatible
(e. g. I
•
Code SLI, Tag-It HFI, my-d vicinity, STM
LRI512)
•
I
•
Code 1 (optional)
•
Security Function (optional)
SAM (Security Access Module),
e.g. for my-d vicinity and my-d proximity
•
Optical Indicators
LED green: running;
LED red: Transponder detected
•
Temperature Range
Operating
Storage
-20°C to +70°C
-40°C to +85°C
•
Radio Approval
Europe
USA
EN 300 330
FCC 47 CFR Part 15
•
EMC
EN 301 489
•
Safety
EN 60950
Summary of Contents for OBID Classic-Pro ID CPR.M02 Series