background image

IDENTIFICATION 

ID ISC.LRU3000 / 3500 

 

 

 

 

Page 6 of 8 

 

Technische Daten 

Technical Data 

 

 

Gehäuse / housing 

Aluminium, pulverbeschichtet / aluminum powder-
coated 

Dimensions ( W x H x D ) 

261,3 mm x 157,3 mm x 68 mm 
10.29 inch x 6.19 inch x 2.68 inch 

Gewicht / weight 

approx. 2.0 kg  (4.4 lb) 

Schutzart / protection class 

IP 53 (with protection cap IP64) 

Spannungsversorgung / supply voltage 
 

LRU3500 (optional): 

24 V DC 

 5 % (Noise Ripple : max. 150 mV) 

PoE (Power over Ethernet) (min. 42,5 V DC) 

(up to 1Watt reader output power)

 

Leistungsaufnahme / power consumption 

max. 35 VA 

Betriebsfrequenz / operating frequency 
 

EU - Reader 

 

FCC - Reader 

 
865,7 MHz 

– 867,5 MHz (4 Channel Plan)) 

902 MHz 

– 928 MHz (FCC 47 CFR Part 15.247) 

Antennenanschlüsse / antenna connections 

4 x SMA socket (50 

RF-Sendeleistung / RF- transmitting power 
 

LRU3000:  

 

LRU3500: 

 
300 mW 

– 2 W (configurable)  

300 mW 

– 4 W (configurable, maximum 1 W by PoE) 

Ausgänge / outputs 
 

2 x optocoupler 

 

3 x relay ( 1 x normal open) 

 
24 V DC / 30 mA (galvanically isolated) 
24 V DC

 

/ 1 A (switching current) / 2 A (constant load) 

Eingänge / inputs 
 

5 x optocoupler 

 
max. 5 V DC - 10 V DC

 

/ 20 mA,  

max. 24 V DC with additional external series resistor 

Schnittstellen / interfaces 

- RS232 
- RS485 
- USB (full speed) 
- Ethernet (TCP/IP) 
- USB Host (for external USB Flash Drive) 

Temperaturbereich / temperature range 

  Betrieb / operation 

 

  Lagerung / storage 

 

-25 °C to +55 °C (-13 °F to +122 °F) 
-25 °C to +50 °C (only LRU3500 powered via PoE) 

-25 °C to +85 °C (-13 °F to +185 °F) 

relative Luftfeuchte / relative air humidity 

5 % -95 % (not condensing) 

 

 

Summary of Contents for ID ISC.LRU3500

Page 1: ...e der Ethernet Schnittstelle Thank you for deciding to purchase the ID ISC LRU3x00 EU FCC The ID ISC LRU3x00 EU FCC is a device for contactless data exchange with common Transponder according to EPC C...

Page 2: ...Class 2 LPS power supply according IEC EN 60950 only Terminal Abbreviation Description X1 Pin 1 VDC Vcc supply voltage 24 V DC 5 X1 Pin 2 GND Ground supply voltage Serielle Schnittstellen Serial Inte...

Page 3: ...C angelegt werden Die digitalen Eing nge werden an Klemme X5 des Lesers angeschlossen The reader is equipped with 5 digital inputs The inputs are designed for a maximum voltage of 10 V DC and a maximu...

Page 4: ...angeschlossen The reader is equipped with 2 digital outputs The outputs are designed for a maximum voltage of 24 V DC and a maximum current of 30 mA The digital outputs are connected to Terminal X5 o...

Page 5: ...voltage of 24 V DC and a maximum current of 2 A The switching current should not exceed 1 A The relay outputs are connected to Terminal X5 of the reader X5 Eine Verpolung oder berlastung des Ausgangs...

Page 6: ...Plan 902 MHz 928 MHz FCC 47 CFR Part 15 247 Antennenanschl sse antenna connections 4 x SMA socket 50 RF Sendeleistung RF transmitting power LRU3000 LRU3500 300 mW 2 W configurable 300 mW 4 W configur...

Page 7: ...correct the interference at his own expense Le pr sent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autoris e aux deux conditi...

Page 8: ...m separation of 23 cm 9 inch between antenna and the human body must be maintained The operation manual should be conveniently kept available at all times for each user Unauthorized changes and the us...

Reviews: