Identification System OBID
i-scan
Page 18 of 20
FEIG ELECTRONIC GmbH
5.2. Setting addresses for bus operation
For bus operation the Reader allows you to set the required bus address either using DIP switch
S2 or through the software.
a) Setting the bus address on S2 :
Addresses „0“ to „7“ can be set on S2.
To set the bus address using S2, the Reader must be set to software address „0“ (factory set-
ting).
Address
Switch 1
Switch 2
Switch 3
0
OFF
OFF
OFF
1
OFF
OFF
ON
2
OFF
ON
OFF
3
OFF
ON
ON
4
ON
OFF
OFF
5
ON
OFF
ON
6
ON
ON
OFF
7
ON
ON
ON
b) Setting the bus address through software
Addresses are assigned through the host computer. The software is used to assign addresses “0”
to “253” to the Reader.
Note:
Since all Readers are factory set to Address 0, they must be connected and configured one
after the other.