IDENTIFICATION
Installation
Wiegand Switch
FEIG ELECTRONIC GmbH
Page 18 of 18
M80211-0e-ID-B.docx
10.1.2. Configuration
Figure 11: Example for relay settings in the reader configuration shows an example for possible
settings in the reader configuration. In that scenario two antennas are connected to the reader.
Each antenna is used to control a separate lane. If a transponder is detected by antenna 1 the re-
lay of the reader stays off. Data is transmitted by Output A of the Wigand Switch to the Access
Controller. If a transponder is read by antenna 2 the relay output of the reader is switched on. Data
is transmitted by Output B of the Wiegand Switch to the Access Controller.
Figure 11: Example for relay settings in the reader configuration
NOTE:
The
relay “Setting Time” need to be set to (00001 x 100 ms)
Table 8: Settings for 2 gates with one antenna per lane
Gate
Antenna assignment
Read Event Activation
Output Wiegand Switch
1
ANT1
False
OUT A
2
ANT2
True
OUT B
Table 9: Settings for 2 Gates with 2 antennas per lane
Gate
Antenna assignment
Read Event Activation
Output Wiegand Switch
1
ANT1
False
OUT A
1
ANT2
False
OUT A
2
ANT3
True
OUT B
2
ANT4
True
OUT B