3.1  Performance Features of the People Counter ID ISC.ANT1700/740-GPC 

The product ID ISC.ANT1700/740-

GPC, short form “Gate People Counter” or  “GPC”, are made for 

mounting in the gate antennas ID ISC.ANT1700/740. 

A Gate People Counter consist of a People Counter board (PC) and one Radar Detector! The 
product ID ISC.ANT.GPC-E Extension Radar Detector is used to extend the People Counter to a 
second gate aisles. 

The People Counter has two counters per aisle. The values of the incoming and out going persons 
will be separately captured. 

 

 

 

 

 

 

 

 

 

 

 

Fig. 1: Gate People Counter Structure (2-3 antennas, 1-2 gate aisles) 

A change of the counter values will be stored in the EEPROM of the People Counter Board. With 
the command “0x78 Set People Counter” the values could be set/reset to the needed value. 

People  

Counter 1 

Radar 

Detector 1 

Out / LED 1-3 

ID ISC.ANT.GPC-E 

Extension Radar Detector 

(e.g. 2’nd aisle of the gate) 

Radar 

Detector 2 

Two gate antennas  

ID ISC.ANT1700/740-GPC 

Reader 

Summary of Contents for ID ISC.ANT1700/740-SLA

Page 1: ...INSTALLATION final public B 2010 10 11 M00210 2e ID B doc ID ISC ANT1700 740 SLA SLB Clear Gate English...

Page 2: ...s given in this manual are based on advantageous boundary conditions FEIG ELECTRONIC GmbH does not give any guarantee promise for perfect function in cross environments and does not give any guaranty...

Page 3: ...ing Holes 15 4 4 Installing the Antenna Body 17 5 Typical Antenna Configuration Gate Antenna with two Antennas 18 5 1 Project Notes 18 5 2 Gate Configuration and Setup using Antennas Type SLA and SLB...

Page 4: ...6 2 Installation ID ISC ANT GPC E 49 6 3 Configuration and Test 52 6 3 1 Connecting several People Counter 53 6 3 2 Configuration and Test in ISO Host or Buffered Read 54 6 3 3 Configuration and Test...

Page 5: ...by qualified personnel Use of the device and its installation must be in accordance with national legal requirements and local electrical codes When working on devices the valid safety regulations mus...

Page 6: ...dust and other impurities with a soft cloth and a solution of water with a little dishwashing liquid Keep the antenna dry All kinds of moisture should be avoided during operation and storage Precipit...

Page 7: ...hs are possible The ID ISC ANT1700 740 SLA SLB is a single loop antenna with tuner and have been optimized as transmitting and receiving antennas for the ID ISC LRM2000 Reader It is however also possi...

Page 8: ...ion Radar Detector is used to extend the People Counter to a second gate aisles The People Counter has two counters per aisle The values of the incoming and out going persons will be separately captur...

Page 9: ...ennas 1 2 gate aisles The People Counter board and the Radar detectors are mounted in the base of the antennas Due to the radar beam can pervade the plastic housing of the antenna no openings a necess...

Page 10: ...ack Command of the reader Normally the host poll the GPC by sending protocols Only in the Notification Mode the reader poll the counter values automatically and send data according the reader configur...

Page 11: ...indow for Clear antennas ID ISC ANT1700 740 GPC Gate People Counter People Counter and one piece of radar detector for antenna ID ISC ANT1700 740 incl Mounting and cabling set optional ID ISC ANT GPC...

Page 12: ...of 8 m must be kept between the antennas or gates For shorter distances 1 m 8 m the readers must be synchronized The synchronization of the readers is only possible in one of the Automatic Modes Buff...

Page 13: ...owing steps 1 Place the packed antenna on the floor with the top side facing up Carefully open the box and then remove the antenna Fig 3 Antenna in its packaging 2 After that the antenna has to be pla...

Page 14: ...CTRONIC GmbH Page 14 of 66 M00210 2e ID B doc 4 2 Dimensions of antenna The outside dimensions of the antenna are shown in Fig 5 Fig 5 Antenna outside dimensions All dimensions are in mm with general...

Page 15: ...or for all load directions e g for concrete floor Hilti HVA anchors with HAS E M8 threaded rod or Hilti HIS N M8 5 16 threaded inserts The size of the mounting holes in the antenna is 10 mm 39 The len...

Page 16: ...ation ID ISC ANT1700 740 SLA SLB FEIG ELECTRONIC GmbH Page 16 of 66 M00210 2e ID B doc Alternatively the cables can be routed at the sides of the antenna bas like shown in Fig 8 Fig 8 Cable routing at...

Page 17: ...will be screwed on the floor The transverse antenna conductors in the middle of the antenna body have to face the same direction at all antennas Fig 9 Use the adjusting screws Fig 10 to align the ante...

Page 18: ...ystem 5 1 Project Notes The antenna configuration as described allows detection of a tag moving horizontally through the capture area of the gate The tag orientation is non critical The tags are detec...

Page 19: ...distances under 5 cm The maximum number of tags serial number or data depends on the traverse speed with which the tags are brought through the capture area of the gate see Table 4 Design notes The nu...

Page 20: ...NIC GmbH Page 20 of 66 M00210 2e ID B doc Gate with antenna Type SLA and Type SLB Gate distance GD 130 cm Number of tags at a speed of 1 m s Read serial number Read data 16 8 Table 4 Design notes A mi...

Page 21: ...NET24V B Power Supply Unit Power cable interface cable and connection cable for the DC power supplies 2 wire twisted Mounting materials screws anchors Optional Qty 2 ID ISC ANT1700 740 AGP Acrylic gla...

Page 22: ...able should be mounted already Normally the antenna cable from antenna Type B has to be connected to OUT2 at the multiplexer and the 24V DC power supply to X11 of the terminal board only Optional the...

Page 23: ...e need to be tied into small loops see Fig 14 Tie all cables as far away from the antenna conductor as possible The cables must never be allowed to contact the antenna conductor The cable from antenna...

Page 24: ...ELECTRONIC GmbH Page 24 of 66 M00210 2e ID B doc 5 2 3 Setting the Multiplexer Set the jumpers JP11 JP18 shown More on setting the ID ISC ANT MUX M4 Multiplexer can be found in the corresponding inst...

Page 25: ...over and move it upwards Fig 17 Step 1 Step 2 Fig 17 Opening of the antenna base The antennas ID ISC ANT1700 740 SLA SLB are factory set as follows Table 5 Jumper settings for Antenna Tuner Function J...

Page 26: ...ol Pin configuration X8 RS232 interface Terminal Abbreviation Description 1 GND RS232 GND 2 RxD RS232 RxD 3 TxD RS232 TxD Table 6 RS232 interface pin outs Fig 18 Wiring example for connecting the RS23...

Page 27: ...made on X11 With structured cabling Cat 5 cables should be used This ensure reliable operation at 10Mbps or 100Mbps The default IP address is 192 168 10 10 Port 10001 Sub Net Mask 255 255 0 0 More In...

Page 28: ...e antennas open the ISOStart software and read out the current configuration of the Reader Step Action Note 1 Start ISOStart Software 2 Select Detect 3 Select Keep Configuration unchanged and exit Wiz...

Page 29: ...OBID i scan Installation ID ISC ANT1700 740 SLA SLB FEIG ELECTRONIC GmbH Page 29 of 66 M00210 2e ID B doc Step Action Note 5 Select Expert Mode and confirm with OK 6 Select Logical View...

Page 30: ...o of Output Channels e g 4 Antenna Active Time 100 x 5ms 3 Set by clicking on Apply 4 Transponder Configure the parameters as follows Driver here ISO 15693 Anticollision enable No of Timeslots 1 times...

Page 31: ...ct Reader window select the interface COM Port 1 BusAdr 0 and then click on Detect 3 Use Settings to enter the configuration Single Mode Number of Antennas 4 Click on with Multiplexer Number of Tuning...

Page 32: ...ware and a Transponder Here the Noise Level and performance of the gate are tested 5 3 1 Checking the Noise Level Step Action Note 1 Select Function Unit Command Multiplexer Channel Select activate an...

Page 33: ...e values are not met check the following Are all cables pulled tight and do they make good contact Were the ring cores installed in the antenna cable Were the cables routed as specified Are other RFID...

Page 34: ...adhesive tape for example 2 Activate antenna 1 with command Function Unit Commands Multiplexer Parameter Channel Select Cascade Level 1 Output Channel of Input 1 1 3 Confirm with Send 4 Select Test an...

Page 35: ...des See 5 5 Activating the Automatic Mode A read transponder will be displayed by a blue LED on the reader or by the LED light of the antenna See also 5 4 1 Reader Setting for Indicator In this test t...

Page 36: ...d always be read Then repeat this along the line in the vertical tag direction transverse to the antenna and on the line in the horizontal tag orientation Here again the tag should always be read The...

Page 37: ...the relay contacts are galvanically isolated from the Reader electronics and without internal power supply at X6 or X11 and must therefore be externally supplied The volume of the buzzer could be adju...

Page 38: ...ware 2 Select Configuration and click on Read to read the complete configuration 3 Operating Mode Select Buffered Read Mode 4 Digital IO Output Idle Mode OFF Idle Flash Mode 1Hz Setting Time with Sett...

Page 39: ...in nearly all Transponder models in the ISO15693 family To cancel simply write a different code to the Transponder than for valid Transponders which trigger an alarm Step Action Note 1 Select Command...

Page 40: ...OBID i scan Installation ID ISC ANT1700 740 SLA SLB FEIG ELECTRONIC GmbH Page 40 of 66 M00210 2e ID B doc 7 To verify read AFI byte by using the command 0x2B Get System Information...

Page 41: ...maximum speed and the information is stored in the Reader s ring buffer This data sets can be read by the host To activate Buffered Read Mode proceed as follows Step Action Note 1 Select Configuratio...

Page 42: ...1 piece mounting bracket 2 1 piece Radar connection cable 3 1 piece connection cable People Counter Terminal board 4 1 piece Triggercable 5 1 piece People Counter Board 6 1 piece Radar module 7 5 piec...

Page 43: ...ouch the an tenna surface of the Radar module to avoid damaging the electronic components and soiling 2 Set sensitivity of Radar sensor by setting jumper J1 and J2 Sensitivity JP1 2 open Low JP1 close...

Page 44: ...M00210 2e ID B doc 4 Connect one plug of radar connection cable with X1 of Radar module Here yellow white green brown The other plug will be used for the second radar sensor in case of a gate with tw...

Page 45: ...0 740 SLA SLB FEIG ELECTRONIC GmbH Page 45 of 66 M00210 2e ID B doc 6 Fix the cable with the cable clips beside the coax cable 7 Install People Counter Board with the hexagon spacers and the screws in...

Page 46: ...r connection ca ble onto X11 Sen 1 Here yellow white green brown The other plug should be connected to X12 Sen 2 but has no function at the use of only one radar sen sor Plug connection cable of peopl...

Page 47: ...cable to X7 of reader 12 Plug 5 pin connection plug onto X13 GPC OUT of Terminal Board 13 Installing the People Counter at antennas Type B The installation must be done in the same way like at the ant...

Page 48: ...NIC GmbH Page 48 of 66 M00210 2e ID B doc Fig 21 Connections ID ISC ANT1700 740 GPC Long Range Reader ID ISC LRM2000 A X6 X7 Gate People Counter ID ISC ANT1700 740 GPC Radar module ID ISC ANT1700 740...

Page 49: ...ece Radar module 3 2 piece Jumper 4 2 piece spilt rivet 3 0mm 5 1 piece cable clip Step Action Note 1 Attention Note Do not touch the an tenna surface of the Radar module to avoid damaging the electro...

Page 50: ...Page 50 of 66 M00210 2e ID B doc 3 Install Radar module with split rivet 3 0mm at the back of the mounting bracket 4 Connect second plug of radar connection cable with X1 of Radar module Here red Gre...

Page 51: ...D ISC ANT1700 740 SLA SLB FEIG ELECTRONIC GmbH Page 51 of 66 M00210 2e ID B doc Fig 1 Connections GPC E 2 Radarmodule Gate People Counter ID ISC ANT1700 740 GPC Radar Module ID ISC ANT1700 740 GPC Rad...

Page 52: ...g 2 Jumper settings RS485 Interface If you want to use several People counters at gate with 3 to 7 aisles you have to set the corres ponding Busaddress The Busaddress could be set by the Dip Switch at...

Page 53: ...you must use 5 pin shielded twisted pair cable Example LiYCY TP 3x2x0 25 The connection X13 GPC Out of the first Terminal Board has to connected to X13 GPC out of the second and third Terminal Board o...

Page 54: ...Action Note 1 Select Configuration 2 Peripheral Devices CFG8 Set People Counter to True 3 Confirm with Apply 4 Select Command Get Reader Info Peripheral Devices 5 Confirm with Send Number of Devices...

Page 55: ...yed In ISO Host or Buffered Read the People Counter has to be polled by the Host Application to get the data In Notification Mode the Reader sends the People Counter Data automatically to the Host 6 3...

Page 56: ...de Select Notification Mode 5 Confirm with Apply 6 Set IP Address and Port for Notification Mode IP Address of Host e g here 192 168 3 213 Port 20005 Set IP Address and Port for People Counter IP Addr...

Page 57: ...are Albania ALB Andorra AND Austria AUT Azerbaijan AZE Belarus BLR Belgium BEL Bulgaria BUL Bosnia and Herzegovina BIH Croatia HRV Cyprus CYP Czech Republic CZE Denmark DNK Estonia EST Finland FIN Fra...

Page 58: ...be configured as follows depending on the installation location Parameter Europe 60dBuA m Air Interface RF Power maximum 4 W RF Modulation 15 Transponder Parameters RF Modulation ISO MODE MOD 10 RF Da...

Page 59: ...24 5 kg with packing Approx 18 0 kg 23 kg with packing Approx 26 5 kg 31 5 kg with packing Approx 25 0 kg 30 kg with packing Enclosure rating IP 43 Color Antenna frame signal white RAL 9003 Antenna ba...

Page 60: ...der Synchronisation Interfaces RS232 RS484 RS422 Ethernet TCP IP Compact Flash II WLAN Protocol Modes FEIG ISO HOST BRM Data Filtering and Data Buffering Scan Mode RS 232 485 422 Notification Mode TCP...

Page 61: ...mm ISO15693 sensitivity minimum field strength Hmin 60 40 mA m rms transmitting power 8 W tag orientation parallel to antenna for horizontal movement through the antenna The maximum antenna distance a...

Page 62: ...ensor Board 100 mm x 40 mm x 16 mm 1 mm 60 mm x 30mm x 25 mm 1 mm Weight ID ISC ANT1700 740 GPC ID ISC ANT GPC E ca 200 g 290 g 0 64 lb with packing ca 50 g 100 g 0 22 lb with packing Mounting No of a...

Page 63: ...h 99 Equipment Classification according to ETSI EN 300 330 and ETSI EN 301 489 Class 1 The technical data of the ID ISC LRM2000 Reader built into the ID ISC ANT1700 740 SLA antenna can be found in the...

Page 64: ...OBID i scan Installation ID ISC ANT1700 740 SLA SLB FEIG ELECTRONIC GmbH Page 64 of 66 M00210 2e ID B doc 8 3 2 USA and Canada UL The following picture indicates the label position...

Page 65: ...4 TRG Trigger People Counter 1 X4 Pin 1 TRG Trigger People Counter X4 Pin 2 GND Trigger People Counter X5 GPC in Connection Cable to People Counter X5 Pin 1 24V DC LED2 X5 Pin 2 24V DC LED3 X5 Pin 3 n...

Page 66: ...13 GPC out Connection Cable to 2 People Counter X13 Pin 1 24 V DC People Counter 2 X13 Pin 2 GND GND People Counter 2 X13 Pin 3 TRG Trigger People Counter X13 Pin 4 RS485 A X13 Pin 5 RS485 B X14 LED3...

Reviews: