UHF-Reader
Manual
ID ISC.ANT.U500/270 - DM
FEIG ELECTRONIC GmbH
Page 101 of 117
H71011-0e-ID-B.docx
11.3. [0x6E] UPC Diagnostic
The command Reader Diagnostic displays several hardware diagnostics on the UPC.
Host
UPC
Byte
1
2
3
4
5
6
7 .. 8
Contents
STX
(0x02)
MSB
ALENGTH
LSB
ALENGTH
COM-ADR
[0x6E]
MODE
CRC16
Host
UPC
Byte
1
2
3
4
5
6
7 .. n-2
n-1 .. n
Contents
STX
(0x02)
MSB
ALENGTH
LSB
ALENGTH
COM-ADR
[0x6E]
STATUS
DATA
CRC16
MODE:
Reader Diagnostic Modes
0x04
Listing of detail information for STATUS = 0x10 (EEPROM-Failure)
DATA:
Response for corresponding Diagnostic Modes
STATUS:
0x00 Status OK
MODE = 0x04:
Byte
5-6
Contents
INT_ERROR
INT_ERROR:
Bit
15
14
13
12
11
10
9
8
Function
-
-
-
-
-
-
-
--
Bit
7
6
5
4
3
2
1
0
Function
-
-
-
-
-
-
-
EE DEV
EE_DEV:
Communication failure with internal EEPROM