• Ambient air temperature range: during operation -10 ° C to +40 ° C; after transport and storage: -20 ° C to +55 ° C; 
• Relative humidity: up to 50% at 40 ° C; up to 90% at 20 ° C; 
• Ambient air, free of quantities of dust, acids, corrosive gases or abnormal corrosive substances, etc. apart from those 

generated by the welding process; 
• Altitude above sea level at 1000 m; 
• Without hydrocarbon mud oil, water vapor and corrosive gas. 
• No vibration and movement 
• Waterproof and with shelter 
• Ventilation more than 300mm from the wall to ensure a cooling air flow and excellent ventilation. 

 

7. Other information about the machine: 
• Cooling method: Fan cooling 
• Handle provided for moving 
• Characteristic of the welding machine: falling characteristic 
• Contents of attachments: Welding cable, welding electrode holder and earth clamp, face mask, welding brush, carton 

box. 

 

Electric shock

——

may lead to death 

 

·

  Set the earth fitting according to applying standard. 

·

  It is forbidden to touch the electric parts and electrode when the skin is naked, wearing wet gloves 

or clothes. 

·

  Make sure you are insulated from the ground and the workshop. 

·

  Make sure you are in safe position. 

Gas

——

may be harmful to health! 

·

Keep your head out of the gas. 

·

When arc welding, air extractor should be used to prevent from breathing gas.   

Arc radiation

——

Harmful to your eye and burn your skin. 

·

Use suitable helmet and light filter, wear protective garment to protect eye and body. 

Fire 

·

Welding spark may cause fire, make sure the welding area no tinder around. 

Noise

——

extreme noise harmful to ear. 

·

Use ear protector or others means to protect ear. 

·

Warn that noise harmful to hearing if looker-on around. 

Malfunction

——

When trouble, count on the professionals 

·

If trouble in installation and operation, please follow this manual instruction to check up. 

·

If fail to fully understand the manual, or fail to solve the problem with the instruction, you should 

contact the suppliers or our service center for professional help. 

 

        CAUTION

 

Summary of Contents for FPSI140A

Page 1: ...ORIGINAL INSTRUCTIONS FEIDER WELDING MACHINE FPSI140A READ TTHE INSTRUCTIONS BEFORE USE THE TOOL FEIDER ZI 32 rue Aristide Berg s 31270 Cugnaux France...

Page 2: ...void placing the welding machine on a wet surface and avoid working on a wet surface Do not expose the power cable to water Make sure that the cable holder or welding electrode is not squeezed by heav...

Page 3: ...ficulties in the installation or operation please seek help from a qualified service Do not use of a welding power source for pipe thawing Warning 1 Install the leakage protection device when using th...

Page 4: ...general the automatic voltage compensation circuit in the welding machine will ensure that the welding current is within the allowed range When the power source voltage exceeds the allowed value the w...

Page 5: ...not allow the user to work safely Avoid using the machine in a humid environment in which operators can sweat and this is a high risk of electrocution Avoid welding in a dusty environment under a corr...

Page 6: ...rth fitting according to applying standard It is forbidden to touch the electric parts and electrode when the skin is naked wearing wet gloves or clothes Make sure you are insulated from the ground an...

Page 7: ...ed with the ground Put the fastening plug into the fastening socket at the polarity and fasten it clockwise 4 Put the fastening plug of the cable to fastening socket of polarity at the front panel fas...

Page 8: ...30 280A 4 Knob of arc striking drive is use to adjust welding function specially in low current arrange that is cooperated with knob of welding current adjustment they may adjust current of arc striki...

Page 9: ...ents and natural wind will not satisfy machine cool demands So there is a fan in inter machine to cool down machine Make sure the intake is not in block or covered it is 0 3 meter from welding machine...

Page 10: ...tage is lower than rated value the max output may lower than rated value C Current is not stabilizing when machine is been operating It has something with factors as following 1 Electric wire net volt...

Page 11: ...to operate machine as following the operator must be a personnel in a specific field of electricity and safety and hold the relevant certificate that proves there ability and knowledge Before maintena...

Page 12: ...e Open the voltage circuit for a second winding U2 Tension charge Output voltage of rated load U2 20 0 04I2 V A V A V Current regulation range and corresponding charging voltage IP Degree of protectio...

Page 13: ...n Directive 2012 19 EU on waste electrical and electronic equipment and its implementation into national law electrical products used must be collected separately and disposed of at collection points...

Page 14: ...tor is not lit there is no welding output A Check if components are poor connects B Check if connector of output terminal is break circuit and poor connect C Check voltage between power source board a...

Page 15: ...f technical file M Oliver Patriarca Is in conformity with the Directive 2006 42 CE and to the regulation transposing it Also in conformity with the following Directives EMC Directive 2014 30 UE ROHS D...

Reviews: