Feider FPSI140A Original Instructions Manual Download Page 5

 

• In environments classified as hazardous, use only welding machines with the S mark and a safe level of idle voltage. 

These working environments include, for example, small spaces, humid or hot spaces in which the user will be directly 

exposed to the surrounding conductive parts. 
• You must be careful to prevent the unit from tipping over if the welding power is tilted. 
• It is forbidden to use the power plug to thaw the network. 
• Isolate yourself from the welding circuit using dry equipment and unprotected protective clothing. 
• Never touch the work piece and work rod, welding electrode or contact tip at the same time. 
• Avoid placing the electrode holder on the welding machine and other electrical equipment. 

 

5. Transport, lifting and suspension 
• Never press or lift the machine with an electrode holder or other parts. Always use lifting points or handles designed 

for this function. 
• Use only a protective platform designed for the equipment. 
• Always try to transport the machine upright if possible. 
• Never use a welding machine while it is hanging. 
• Never exceed the maximum permissible limit for the load of wheels, suspensions or carts of welding equipment. 

 

6. Environment 
• When the action of the operator is limited by the environment (in particular: could only work when lowered on the 

knees, on the floor or even lying down), any direct contact with the room carrying the current should be avoided with 

the body . 
• Do not use the machine when the environmental operating space is very narrow and would not allow the user to work 

safely. 
• Avoid using the machine in a humid environment in which operators can sweat and this is a high risk of electrocution. 
• Avoid welding in a dusty environment under a corrosive gas environment. 
• For welding machines intended to perform welds with a gas supply, avoid carrying out the welding work under a large 

air flow environment. 
• The inclination between the placement and the welding machine and the flat horizon is ≤10 °. 

  
• The welding power source is not suitable for use in rain or snow, although it could use and store outdoors. Protect the 

environment against rain, water and the sun very strong. 
• Store the machine in a dry and clean area. Protect against rain and temperatures should not reach + 25 ° C in direct 

sunlight. 
• Protect the machine against sand and dust during use and storage. 
• Place the machine so that it is not exposed to hot surfaces, sparks or splashes. 
• Ensure that the flow of air and from and to the machine is unlimited. 
• The EMC classification for this product is Class A in accordance with EN 60974-10 for electromagnetic compatibility. 

The product is therefore designed to be used only in an industrial environment. 
• Arc welding equipment still creates electromagnetic problems in hospitals. To minimize the hazardous effects, only 

use the equipment in accordance with the instruction manual and other recommendations. 

 

WARNING: This Class A equipment is not intended for use in private homes having a power supply provided by a low 

voltage power system. In such locations, it may be difficult to ensure electromagnetic compatibility due to radiation and 

driving problems. 

 

Make sure that the welding rod is placed according to the following instructions: 

Summary of Contents for FPSI140A

Page 1: ...ORIGINAL INSTRUCTIONS FEIDER WELDING MACHINE FPSI140A READ TTHE INSTRUCTIONS BEFORE USE THE TOOL FEIDER ZI 32 rue Aristide Berg s 31270 Cugnaux France...

Page 2: ...void placing the welding machine on a wet surface and avoid working on a wet surface Do not expose the power cable to water Make sure that the cable holder or welding electrode is not squeezed by heav...

Page 3: ...ficulties in the installation or operation please seek help from a qualified service Do not use of a welding power source for pipe thawing Warning 1 Install the leakage protection device when using th...

Page 4: ...general the automatic voltage compensation circuit in the welding machine will ensure that the welding current is within the allowed range When the power source voltage exceeds the allowed value the w...

Page 5: ...not allow the user to work safely Avoid using the machine in a humid environment in which operators can sweat and this is a high risk of electrocution Avoid welding in a dusty environment under a corr...

Page 6: ...rth fitting according to applying standard It is forbidden to touch the electric parts and electrode when the skin is naked wearing wet gloves or clothes Make sure you are insulated from the ground an...

Page 7: ...ed with the ground Put the fastening plug into the fastening socket at the polarity and fasten it clockwise 4 Put the fastening plug of the cable to fastening socket of polarity at the front panel fas...

Page 8: ...30 280A 4 Knob of arc striking drive is use to adjust welding function specially in low current arrange that is cooperated with knob of welding current adjustment they may adjust current of arc striki...

Page 9: ...ents and natural wind will not satisfy machine cool demands So there is a fan in inter machine to cool down machine Make sure the intake is not in block or covered it is 0 3 meter from welding machine...

Page 10: ...tage is lower than rated value the max output may lower than rated value C Current is not stabilizing when machine is been operating It has something with factors as following 1 Electric wire net volt...

Page 11: ...to operate machine as following the operator must be a personnel in a specific field of electricity and safety and hold the relevant certificate that proves there ability and knowledge Before maintena...

Page 12: ...e Open the voltage circuit for a second winding U2 Tension charge Output voltage of rated load U2 20 0 04I2 V A V A V Current regulation range and corresponding charging voltage IP Degree of protectio...

Page 13: ...n Directive 2012 19 EU on waste electrical and electronic equipment and its implementation into national law electrical products used must be collected separately and disposed of at collection points...

Page 14: ...tor is not lit there is no welding output A Check if components are poor connects B Check if connector of output terminal is break circuit and poor connect C Check voltage between power source board a...

Page 15: ...f technical file M Oliver Patriarca Is in conformity with the Directive 2006 42 CE and to the regulation transposing it Also in conformity with the following Directives EMC Directive 2014 30 UE ROHS D...