background image

INTERIOR

EXTERIOR

36"

2-3/4" MIN. LAG PENETRATION

6" LAG SCREWS,

PART #7278

42"

RESIDENTIAL (MAX 6' OC)

38"-42"

COMMERCIAL (MAX 4' OC)

3-5/8" MIN. LAG PENETRATION

6-1/2" LAG SCREWS,

PART #7209

3" MIN. LAG PENETRATION

6" LAG SCREWS,

PART #7278

4" MIN. LAG PENETRATION

7" LAG SCREWS,

PART #7248

VINYL CAP

3/8" Ø LAG SCREW
(REFER TO CHART

FOR LENGTH
REQUIREMENTS)

T H I S   D RA W I N G  I S   T H E   P R O P E R T Y   O F   F E E N E Y   I NC .     A N Y   R E P RO DU CT I ON   O F   T H I S   D OC UM E NT   W I T HO U T   T HE   E X P R E S S E D   W RI T T E N   CO NS E N T   O F   F E E NE Y   I N C.   I S   S T R I C T L Y   P R O HI B I T E D .

DATE:
PAGE:
REV:
BY:
CHK:

2603 Union St., Oakland, CA 94607

P: 800-888-2418  F: 510-788-6041

www.feeneyinc.com

DesignRail

®

 Detail Drawing:

Fasica Mount with Lag Screws

06/10/15

1 OF 1

BWA

NOTES:
MINIMUM LAG PENETRATION DIMENSION, REFER TO REQUIREMENTS FOR
LAG SCREW PENETRATION INTO SOLID LUMBER.  LUMBER ASSUMED TO
HAVE A MINIMUM 0.43 SPECIFIC GRAVITY (ie: HEM-FIR).

RIM JOIST AND BLOCKING MUST BE PROPERLY ATTACHED TO STRUCTURE

TO RESIST TRANSFERRED LOADS FROM POSTS.

IF USING COMPOSITE MATERIAL AS FASCIA BOARD, FASCIA THICKNESS

WILL NOT CONTRIBUTE TO PENETRATION REQUIREMENT.  LAG SCREW

LENGTH AND BLOCKING MUST BE ADJUSTED TO ACCOUNT FOR

ADDITIONAL LENGTH, AS NECESSARY.

BOLT PATTERN MAY VARY DEPENDING ON JOIST HEIGHT AND PROJECT

TYPE.

3" MIN. LAG PENETRATION

6" LAG SCREWS,

PART #7278

4" MIN. LAG PENETRATION

7" LAG SCREWS,

PART #7248

RIM JOIST WITH
REQUIRED
BLOCKING

CAP WASHER,
PART #7063

Reviews: