F=00021.00000kHz

AMPL=05.00V TRGL

The waveform selected is “Triangle”

F=00021.00000kHz

AMPL=05.00V PULSE

The waveform selected is “Pulse”

F=00021.00000kHz

AMPL=05.00V 4-PUL

The waveform selected is “4 square pulse”

F=00021.00000kHz

AMPL=05.00V 8-PUL

The waveform selected is “4 square pulse”

3

To set the amplitude

Press

AMPL

button to make the cursor stay under the amplitude value (AMPL=). The

Amplitude value is the Vpp of signal. Use

】、【

】、【

to change the value

F=00021.00000kHz

AMPL=05.00V TRGL

4

To set the offset

Press

OFFS

button to make the cursor stay under the offset value (OFS=). Then use

】、

】、【

to change the offset value

F=00021.00000kHz

OFS=01.00V TRGL

5

To set the duty cycle

Press

MENU

button to make the cursor stay under the duty cycle value (DUTY=). Then use

】、【

】、【

to change the duty cycle value

Only available for Square and

Triangle

.

Duty cycle of Square can be set during 1%~99%.

F=00021.00000kHz

DUTY=50%

SQUR

(WAVE=SQUR)

F=00021.00000kHz

DUTY=80%

SQUR

(WAVE=SQUR)

6

To set the pulse width

Press

MENU

button to make the cursor stay under Pulse Value

Pul=

. Use

】、【

】、【

to set the pulse width value

The time unit can be changed

):

Summary of Contents for FY2300 series

Page 1: ...FeelTech FY2300 Series Fully Numerical Control DDS Signal Generator User s Manual Rev2 0 Feb 2016...

Page 2: ......

Page 3: ...n in this publication replaces all previously corresponding material FeelTech shall not be liable for losses caused by either incidental or consequential in connection with the furnishing use or perfo...

Page 4: ......

Page 5: ...interference immunity and operational life span The advantages of this instrument in signal generating waveform sweeping parameter measurement and other fields make it to be the ideal equipment for e...

Page 6: ...n can output any CMOS electric level with amplitude during 0 10V Save Function It can save 30 sets of user defined parameters and can be loaded at anytime It has built in 60MHz frequency meter and cou...

Page 7: ...the cursor twinkles under the frequency value If not please keep pressing MENU button to move the cursor to the first line Use button to change the value of frequency for increasing for decreasing F...

Page 8: ...to change the value F 00021 00000kHz AMPL 05 00V TRGL 4 To set the offset Press OFFS button to make the cursor stay under the offset value OFS Then use to change the offset value F 00021 00000kHz OFS...

Page 9: ...witch between frequency meter and counter 1 Frequency measurement mode ExtF 21 000kHz FUNC EXT TREQ Measure FREQ 2 Pulse counter mode CNTR 0 FUNC COUNGTER Measure COUNT Press OK button canreset the co...

Page 10: ...10 ms The step value is calculated by the instrument itself 9 Load Save function Press SYS button to enter Save Load function This function allow the user to save to or load from M0 M30 for frequency...

Page 11: ...w Press Output again to turn on the output F 00021 00000kHz AMPL 05 00V OFF Other Functions 1 Dual Channel TTL output 2 Buzzer It beeps each time press a button The beep will last a while if operation...

Page 12: ...5MHz Ramp Triangle 0 2MHz 0 5MHz 0 5MHz 0 5MHz Pulse 0 2MHz 0 5MHz 0 5MHz 0 5MHz TTL 0 2MHz 0 5MHz 0 5MHz 0 5MHz Others 0 2MHz 0 5MHz 0 5MHz 0 5MHz Resolution 10mHz 0 01Hz Accuracy 5 10 6 Stability 1...

Page 13: ...n 0 01V 0 001V Attenuated TTL output Electrical Level Amplitude 5Vpp Fan out 20 TTL Load Rise Fall Time 20ns CMOS output Low Electric Level 0 3V High Electric Level 1V 10V Rise Fall Time 20ns External...

Page 14: ...erial interface Communicati ng Speed 9600bps Protocol Command line mode protocol complete open Power Voltage Range DC12V Buzzer Can be turned on off by setting Operation Button controlled Environment...

Page 15: ...pecial purpose or use authorization Before the installation and use each parameter of the technical indexes in this manual should be referred to If this suggestion is not obeyed death or serious perso...

Page 16: ...duct is proven to be defective within the respective period FeelTech guarantees the free replacement or repair of products which are approved defective This product enjoy 1 year warranty since its del...