Uplink
FY8300S supports multi-machine uplink, which can provide users more
channels for output. In uplink network, only one master machine can exist. Others
must be set as slave machine. The setting method is as follows:
⚫
S
elect on FY8300S as master machine. Press
SYS
->
CONF
->
M/S
, to set
the UPLINK MODE to be “Master”. Press
UPLI
, to set the UPLINK to be
“
ON
”
.
⚫
Set all other machines to be slave machines. Press
SYS
->
CONF
->
M/S
, to
set the UPLINK MODE to be “
Slave
”.
Press
UPLI
, to set the UPLINK to be
“
ON
”
. Repeat this step to set all slave machines.
⚫
Connect all FY8300S in parallel by SYNC connecter.
⚫
The uplink machines cannot exceed 8 because the driving ability.
When the setting above has been finished, all machines in network will work
synchronously according to the start phase of master machine. When outputting
signal with same frequency, multi channels output can be executed with phase
adjustable.